HL incident on 2022-09-21 — KS

Operator
Great Salt Plains Pipeline Llc
Cause
Natural Force Damage
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$72,916
Incident datetime
2022-09-21 03:08
Report number
Location
KS
Narrative
On 9-21-22 we received a call from the landowner of a possible leak. We excavated and found an electrical power line on top of the pipe with bare wires touching the pipeline. It appeared to burn a small hole on top of the pipe and found melted slag by the damaged area. The service of the power line has been off for at least 10 years og&e said. It appeared at sometime lightening has hit the power pole and the lightening traveled down the wires and damaged the pipe. We replaced a 12ft section of pipe with new pipe.
Detailed record list
Report Received Date
2022-10-18 00:00:00
Iyear
2022
Report Number
20220237
Supplemental Number
37385
Report Type
Supplemental Final
Operator Id
Name
Great Salt Plains Pipeline Llc
Operator Street Address
8301 E 21st St, Suite 370
Operator City Name
Wichita
Operator State Abbreviation
KS
Operator Postal Code
67206
Local Datetime
2022-09-21 10:30:00
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
Commodity Released Type
Crude Oil
Unintentional Release Bbls
10
Recovered Bbls
5
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Notification From Public
Incident Identified Datetime
2022-09-21 03:08:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2022-09-21 10:30:00
Restart Datetime
2022-09-26 02:42:00
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Initial Responder Com Datetime
2022-09-21 15:00:00
On Site Datetime
2022-09-21 11:00:00
Confirmed Discovery Datetime
2022-09-21 15:58:00
Nrc Rpt Datetime
2022-09-21 16:01:00
Nrc Rpt Num
Additional Nrc Report Numbers
1348101
Ignite Ind
No
Upstream Action Taken
Valve Closure
Upstream Valve Close Datetime
2022-09-21 10:30:00
Upstream Valve Type Ind
Automatic
Downstream Action Taken
Valve Closure
Downstream Vlv Close Datetime
2022-09-21 10:30:00
Downstream Valve Type Ind
Automatic
Notify Qualified Indiv Ind
Yes
Qualified Indiv Notif Datetime
2022-09-21 10:30:00
Oil Spill Removal Org Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Great Salt Plains Pipeline, Llc
Segment Name
Cherokee 8 Inch
Onshore State Abbreviation
Ok
Onshore Postal Code
73728
Onshore City Name
Not Within A Municipality
Onshore County Name
Alfalfa
Designated Location
Milepost
Designated Name
53.6
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
48
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Pipe
Pipe Type
Pipe Body
Puddle Weld Ind
No
Pipe Diameter
8
Pipe Wall Thickness
0.219
Pipe Smys
52000
Pipe Specification
X52
Pipe Seam Type
Erw - High Frequency
Pipe Manufacturer
California Steel Industries
Pipe Coating Type
Fusion Bonded Epoxy(Fbe)
Coating Applied Ind
No
Installation Year
2012
Manufactured Year
2011
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
Yes
Soil Remed Ind
Yes
Vegetation Remed Ind
Yes
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
2000
Est Cost Gas Released
800
Est Cost Prop Damage
72916
Est Cost Emergency
0
Est Cost Environmental
1810
Est Cost Other
0
Prpty
77526
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
1000
Mop Psig
1480
Mop Cfr Section
Component Design Pressure �195.406(A)(2)
Maop Established Date
2012-09-18 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
86864
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
Yes
Scada Conf Ind
Yes
Cpm In Place Ind
Yes
Cpm Operating Ind
No
Cpm Functional Ind
No
Cpm Detection Ind
Yes
Cpm Conf Ind
Yes
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Leak was from an electric line.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Natural Force Damage
Cause Details
Lightning
Natural Force Type
Lightning
Lightning Subtype
Secondary Impact Such As Resulting Nearby Fires
Nf Extreme Weather Ind
No
Osf Electrical Arcing Ind
Yes
Preparer Name
A*** C*****
Preparer Title
Manager Of Ehs
Preparer Email
A******@m**********.com
Preparer Telephone
6208860082
Prepared Date
2022-11-28 00:00:00
Authorizer Name
A*** C*****
Authorizer Telephone
6208860082
Authorizer Title
Manager Of Ehs
Authorizer Email
A******@m**********.com
Narrative
On 9-21-22 we received a call from the landowner of a possible leak. We excavated and found an electrical power line on top of the pipe with bare wires touching the pipeline. It appeared to burn a small hole on top of the pipe and found melted slag by the damaged area. The service of the power line has been off for at least 10 years og&e said. It appeared at sometime lightening has hit the power pole and the lightening traveled down the wires and damaged the pipe. We replaced a 12ft section of pipe with new pipe.
Report Received Date 2022-10-18 00:00:00
Iyear 2022
Report Number 20220237
Supplemental Number 37385
Report Type Supplemental Final
Operator Id 39401 PHMSA Enforcement
Name Great Salt Plains Pipeline Llc
Operator Street Address 8301 E 21st St, Suite 370
Operator City Name Wichita
Operator State Abbreviation KS
Operator Postal Code 67206
Local Datetime 2022-09-21 10:30:00
Time Zone Central
Daylight Savings Ind Yes
Location Latitude 36.36035 Google Maps OpenStreetMap
Location Longitude -97.59077 Google Maps OpenStreetMap
Commodity Released Type Crude Oil
Unintentional Release Bbls 10
Recovered Bbls 5
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Notification From Public
Incident Identified Datetime 2022-09-21 03:08:00
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Status When Identified Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind Yes
Shutdown Datetime 2022-09-21 10:30:00
Restart Datetime 2022-09-26 02:42:00
Communication State Fed Ind Yes
Party Initiated Communication Operator
Initial Responder Com Datetime 2022-09-21 15:00:00
On Site Datetime 2022-09-21 11:00:00
Confirmed Discovery Datetime 2022-09-21 15:58:00
Nrc Rpt Datetime 2022-09-21 16:01:00
Nrc Rpt Num 1347897 NRC Report How to search
Additional Nrc Report Numbers 1348101
Ignite Ind No
Upstream Action Taken Valve Closure
Upstream Valve Close Datetime 2022-09-21 10:30:00
Upstream Valve Type Ind Automatic
Downstream Action Taken Valve Closure
Downstream Vlv Close Datetime 2022-09-21 10:30:00
Downstream Valve Type Ind Automatic
Notify Qualified Indiv Ind Yes
Qualified Indiv Notif Datetime 2022-09-21 10:30:00
Oil Spill Removal Org Ind No
Num Pub Evacuated 0
Pipe Fac Name Great Salt Plains Pipeline, Llc
Segment Name Cherokee 8 Inch
Onshore State Abbreviation Ok
Onshore Postal Code 73728
Onshore City Name Not Within A Municipality
Onshore County Name Alfalfa
Designated Location Milepost
Designated Name 53.6
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 48
Crossing No
Pipe Facility Type Intrastate
Item Involved Pipe
Pipe Type Pipe Body
Puddle Weld Ind No
Pipe Diameter 8
Pipe Wall Thickness 0.219
Pipe Smys 52000
Pipe Specification X52
Pipe Seam Type Erw - High Frequency
Pipe Manufacturer California Steel Industries
Pipe Coating Type Fusion Bonded Epoxy(Fbe)
Coating Applied Ind No
Installation Year 2012
Manufactured Year 2011
Material Involved Carbon Steel
Release Type Leak
Leak Type Pinhole
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment No
Remediation Ind Yes
Soil Remed Ind Yes
Vegetation Remed Ind Yes
Water Contam Ind No
Could Be Hca No
Commodity Reached Hca No
Est Cost Oper Paid 2000
Est Cost Gas Released 800
Est Cost Prop Damage 72916
Est Cost Emergency 0
Est Cost Environmental 1810
Est Cost Other 0
Prpty 77526
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Accident Psig 1000
Mop Psig 1480
Mop Cfr Section Component Design Pressure �195.406(A)(2) View CFR 49 §192
Maop Established Date 2012-09-18 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Length Segment Isolated 86864
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind Yes
Scada Conf Ind Yes
Cpm In Place Ind Yes
Cpm Operating Ind No
Cpm Functional Ind No
Cpm Detection Ind Yes
Cpm Conf Ind Yes
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details Leak was from an electric line.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Natural Force Damage
Cause Details Lightning
Natural Force Type Lightning
Lightning Subtype Secondary Impact Such As Resulting Nearby Fires
Nf Extreme Weather Ind No
Osf Electrical Arcing Ind Yes
Preparer Name A*** C*****
Preparer Title Manager Of Ehs
Preparer Email A******@m**********.com
Preparer Telephone 6208860082
Prepared Date 2022-11-28 00:00:00
Authorizer Name A*** C*****
Authorizer Telephone 6208860082
Authorizer Title Manager Of Ehs
Authorizer Email A******@m**********.com
Narrative On 9-21-22 we received a call from the landowner of a possible leak. We excavated and found an electrical power line on top of the pipe with bare wires touching the pipeline. It appeared to burn a small hole on top of the pipe and found melted slag by the damaged area. The service of the power line has been off for at least 10 years og&e said. It appeared at sometime lightening has hit the power pole and the lightening traveled down the wires and damaged the pipe. We replaced a 12ft section of pipe with new pipe.