Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2022-09-16 — TX
Operator
Sunoco Pipeline L.p.
Cause
Other Outside Force Damage
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$25,000
Incident datetime
2022-09-16 09:57
Report number
Location
TX
Narrative
On 9/16/22 at 09:57, a 2nd party row mowing contractor struck the 12-inch corsicana to tyler pipeline with a brush hog at a designed above grade ditch crossing. At 09:58, the control room responded by shutting down the upstream pump and field personnel blocked in the line with mainline valves upstream at corsicana pump station and downstream at tyler meter station. Approximately 200 barrels of crude oil was released and a nearby stream was impacted. Company personnel and oil spill response contractors were mobilized to contain and recover released product. Txrrc was notified and nrc was notified. On 9/17/22 at 18:54, repair work was completed, and the pipeline was restarted. Supplemental report: part g updated to other outside force damage - if damage by car, truck, or other motorized vehicle/equipment not engaged in excavation. The type of vehicle involved in the accident was a john deere 5075e tractor with a 7 ft. Mower. Since type of vehicle cannot be left blank for question 8, motorcycle/atv was selected as the best option. 5mph, motorcycle/atv, off road, 0 and "no" selected for questions 7 through 11 respectively at the recommendation of PHMSA aid to more clearly explain accidents of this nature caused by row mowing activities.
Detailed record list
Report Received Date
2022-10-13 00:00:00
Iyear
2022
Report Number
20220233
Supplemental Number
38127
Report Type
Supplemental Final
Operator Id
18718
Name
Sunoco Pipeline L.p.
Operator Street Address
1300 Main Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2022-09-16 09:57:00
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
32.201379
Location Longitude
-95.723382
Commodity Released Type
Crude Oil
Unintentional Release Bbls
200
Recovered Bbls
200
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Other
Accident Details
Notification From The 2nd Party Contractor
Incident Identified Datetime
2022-09-16 09:57:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2022-09-16 10:02:00
Restart Datetime
2022-09-17 19:00:00
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Initial Responder Com Datetime
2022-09-16 12:30:00
On Site Datetime
2022-09-16 09:57:00
Confirmed Discovery Datetime
2022-09-16 09:57:00
Nrc Rpt Datetime
2022-09-16 12:05:00
Nrc Rpt Num
1347443
Additional Nrc Report Numbers
1347573
Ignite Ind
No
Upstream Action Taken
Valve Closure
Upstream Valve Close Datetime
2022-09-16 09:59:00
Upstream Valve Type Ind
Manual
Downstream Action Taken
Valve Closure
Downstream Vlv Close Datetime
2022-09-16 10:30:00
Downstream Valve Type Ind
Manual
Notify Qualified Indiv Ind
Yes
Qualified Indiv Notif Datetime
2022-09-16 09:58:00
Oil Spill Removal Org Ind
Yes
Osro Activated Datetime
2022-09-16 10:30:00
Osro Arrived On Site Dt
9/16/2022 13:30
Num Pub Evacuated
0
Pipe Fac Name
Corsicana To Tyler
Segment Name
26007 - 12-Inch Corsicana To Tyler Junction
Onshore State Abbreviation
Tx
Onshore Postal Code
75752
Onshore City Name
Athens
Onshore County Name
Henderson
Designated Location
Milepost
Designated Name
312+627
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Aboveground
Incident Area Subtype
In Or Spanning An Open Ditch
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Pipe
Pipe Type
Pipe Body
Puddle Weld Ind
No
Pipe Diameter
12
Pipe Wall Thickness
0.25
Pipe Smys
30000
Pipe Specification
Grade A
Pipe Seam Type
Single Saw
Pipe Manufacturer
Unknown
Pipe Coating Type
Coal Tar
Coating Applied Ind
No
Installation Year
1931
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Mechanical Puncture
Puncture Axial
6
Puncture Circum
0.5
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
Yes
Surface Water Remed Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
Yes
Surface Contam Ind
Yes
Amount Released
200
Rel Water Name
Unnamed Marsh
Could Be Hca
Yes
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
550
Est Cost Prop Damage
25000
Est Cost Emergency
3700000
Est Cost Environmental
20000
Est Cost Other
0
Prpty
3745550
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
419
Mop Psig
784
Mop Cfr Section
Subpart E Pressure Test �195.406(A)(3)
Maop Established Date
2013-03-27 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
38544
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
Yes
Scada Conf Ind
Yes
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
Yes
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Controller actions were prompt and appropriate for the situation.
Employee Drug Test Ind
Yes
Contractor Drug Test Ind
No
Num Employees Tested
1
Num Employees Failed
0
Cause
Other Outside Force Damage
Cause Details
Damage By Car, Truck, Or Other Motorized Vehicle/equipment Not Engaged In Excavation
Outside Force Type
Damage By Car, Truck, Or Other Motorized Vehicle/equipment Not Engaged In Excavation
Vehicle Subtype
Operator's Contractor
Driver Issued Citation Ind
No
Driver In Control Ind
Yes
Estimated Speed
5
Vehicle Type
Motorcycle/atv
Vehicle Travel From
Off-Road
Vehicle Travel Distance Ft
0
Protections Installed Ind
No
Preparer Name
T*** N*******
Preparer Title
Director - Regulatory Compliance
Preparer Email
T************@e*************.com
Preparer Telephone
713-989-7126
Prepared Date
2023-06-02 00:00:00
Authorizer Name
T*** N*******
Authorizer Telephone
713-989-7126
Authorizer Title
Director - Regulatory Compliance
Authorizer Email
T************@e*************.com
Narrative
On 9/16/22 at 09:57, a 2nd party row mowing contractor struck the 12-inch corsicana to tyler pipeline with a brush hog at a designed above grade ditch crossing. At 09:58, the control room responded by shutting down the upstream pump and field personnel blocked in the line with mainline valves upstream at corsicana pump station and downstream at tyler meter station. Approximately 200 barrels of crude oil was released and a nearby stream was impacted. Company personnel and oil spill response contractors were mobilized to contain and recover released product. Txrrc was notified and nrc was notified. On 9/17/22 at 18:54, repair work was completed, and the pipeline was restarted. Supplemental report: part g updated to other outside force damage - if damage by car, truck, or other motorized vehicle/equipment not engaged in excavation. The type of vehicle involved in the accident was a john deere 5075e tractor with a 7 ft. Mower. Since type of vehicle cannot be left blank for question 8, motorcycle/atv was selected as the best option. 5mph, motorcycle/atv, off road, 0 and "no" selected for questions 7 through 11 respectively at the recommendation of PHMSA aid to more clearly explain accidents of this nature caused by row mowing activities.
| Report Received Date | 2022-10-13 00:00:00 |
|---|---|
| Iyear | 2022 |
| Report Number | 20220233 |
| Supplemental Number | 38127 |
| Report Type | Supplemental Final |
| Operator Id | 18718 PHMSA Enforcement |
| Name | Sunoco Pipeline L.p. |
| Operator Street Address | 1300 Main Street |
| Operator City Name | Houston |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77002 |
| Local Datetime | 2022-09-16 09:57:00 |
| Time Zone | Central |
| Daylight Savings Ind | Yes |
| Location Latitude | 32.201379 Google Maps OpenStreetMap |
| Location Longitude | -95.723382 Google Maps OpenStreetMap |
| Commodity Released Type | Crude Oil |
| Unintentional Release Bbls | 200 |
| Recovered Bbls | 200 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Other |
| Accident Details | Notification From The 2nd Party Contractor |
| Incident Identified Datetime | 2022-09-16 09:57:00 |
| System Part Involved | Onshore Pipeline, Including Valve Sites |
| On Off Shore | Onshore |
| Status When Identified | Normal Operation, Includes Pauses Between Batches And During Maintenance |
| Shutdown Due Accident Ind | Yes |
| Shutdown Datetime | 2022-09-16 10:02:00 |
| Restart Datetime | 2022-09-17 19:00:00 |
| Communication State Fed Ind | Yes |
| Party Initiated Communication | Operator |
| Initial Responder Com Datetime | 2022-09-16 12:30:00 |
| On Site Datetime | 2022-09-16 09:57:00 |
| Confirmed Discovery Datetime | 2022-09-16 09:57:00 |
| Nrc Rpt Datetime | 2022-09-16 12:05:00 |
| Nrc Rpt Num | 1347443 NRC Report How to search |
| Additional Nrc Report Numbers | 1347573 |
| Ignite Ind | No |
| Upstream Action Taken | Valve Closure |
| Upstream Valve Close Datetime | 2022-09-16 09:59:00 |
| Upstream Valve Type Ind | Manual |
| Downstream Action Taken | Valve Closure |
| Downstream Vlv Close Datetime | 2022-09-16 10:30:00 |
| Downstream Valve Type Ind | Manual |
| Notify Qualified Indiv Ind | Yes |
| Qualified Indiv Notif Datetime | 2022-09-16 09:58:00 |
| Oil Spill Removal Org Ind | Yes |
| Osro Activated Datetime | 2022-09-16 10:30:00 |
| Osro Arrived On Site Dt | 9/16/2022 13:30 |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Corsicana To Tyler |
| Segment Name | 26007 - 12-Inch Corsicana To Tyler Junction |
| Onshore State Abbreviation | Tx |
| Onshore Postal Code | 75752 |
| Onshore City Name | Athens |
| Onshore County Name | Henderson |
| Designated Location | Milepost |
| Designated Name | 312+627 |
| Federal | No |
| Location Type | Pipeline Right-Of-Way |
| Incident Area Type | Aboveground |
| Incident Area Subtype | In Or Spanning An Open Ditch |
| Crossing | No |
| Pipe Facility Type | Intrastate |
| Item Involved | Pipe |
| Pipe Type | Pipe Body |
| Puddle Weld Ind | No |
| Pipe Diameter | 12 |
| Pipe Wall Thickness | 0.25 |
| Pipe Smys | 30000 |
| Pipe Specification | Grade A |
| Pipe Seam Type | Single Saw |
| Pipe Manufacturer | Unknown |
| Pipe Coating Type | Coal Tar |
| Coating Applied Ind | No |
| Installation Year | 1931 |
| Manufactured Year | Unknown |
| Material Involved | Carbon Steel |
| Release Type | Mechanical Puncture |
| Puncture Axial | 6 |
| Puncture Circum | 0.5 |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | No |
| Remediation Ind | Yes |
| Surface Water Remed Ind | Yes |
| Soil Remed Ind | Yes |
| Water Contam Ind | Yes |
| Surface Contam Ind | Yes |
| Amount Released | 200 |
| Rel Water Name | Unnamed Marsh |
| Could Be Hca | Yes |
| Commodity Reached Hca | No |
| Est Cost Oper Paid | 0 |
| Est Cost Gas Released | 550 |
| Est Cost Prop Damage | 25000 |
| Est Cost Emergency | 3700000 |
| Est Cost Environmental | 20000 |
| Est Cost Other | 0 |
| Prpty | 3745550 |
| Num Persons Hosp Not Ovnght | 0 |
| Num Injured Treated By Emt | 0 |
| Num Resident Building Affctd | 0 |
| Num Business Building Affctd | 0 |
| Accident Psig | 419 |
| Mop Psig | 784 |
| Mop Cfr Section | Subpart E Pressure Test �195.406(A)(3) View CFR 49 §192 |
| Maop Established Date | 2013-03-27 00:00:00 |
| Maop Reversal Flow Ind | No |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Length Segment Isolated | 38544 |
| Internal Inspection Ind | Yes |
| Operation Complications Ind | No |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | Yes |
| Scada Conf Ind | Yes |
| Cpm In Place Ind | Yes |
| Cpm Operating Ind | Yes |
| Cpm Functional Ind | Yes |
| Cpm Detection Ind | No |
| Cpm Conf Ind | Yes |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | Controller actions were prompt and appropriate for the situation. |
| Employee Drug Test Ind | Yes |
| Contractor Drug Test Ind | No |
| Num Employees Tested | 1 |
| Num Employees Failed | 0 |
| Cause | Other Outside Force Damage |
| Cause Details | Damage By Car, Truck, Or Other Motorized Vehicle/equipment Not Engaged In Excavation |
| Outside Force Type | Damage By Car, Truck, Or Other Motorized Vehicle/equipment Not Engaged In Excavation |
| Vehicle Subtype | Operator's Contractor |
| Driver Issued Citation Ind | No |
| Driver In Control Ind | Yes |
| Estimated Speed | 5 |
| Vehicle Type | Motorcycle/atv |
| Vehicle Travel From | Off-Road |
| Vehicle Travel Distance Ft | 0 |
| Protections Installed Ind | No |
| Preparer Name | T*** N******* |
| Preparer Title | Director - Regulatory Compliance |
| Preparer Email | T************@e*************.com |
| Preparer Telephone | 713-989-7126 |
| Prepared Date | 2023-06-02 00:00:00 |
| Authorizer Name | T*** N******* |
| Authorizer Telephone | 713-989-7126 |
| Authorizer Title | Director - Regulatory Compliance |
| Authorizer Email | T************@e*************.com |
| Narrative | On 9/16/22 at 09:57, a 2nd party row mowing contractor struck the 12-inch corsicana to tyler pipeline with a brush hog at a designed above grade ditch crossing. At 09:58, the control room responded by shutting down the upstream pump and field personnel blocked in the line with mainline valves upstream at corsicana pump station and downstream at tyler meter station. Approximately 200 barrels of crude oil was released and a nearby stream was impacted. Company personnel and oil spill response contractors were mobilized to contain and recover released product. Txrrc was notified and nrc was notified. On 9/17/22 at 18:54, repair work was completed, and the pipeline was restarted. Supplemental report: part g updated to other outside force damage - if damage by car, truck, or other motorized vehicle/equipment not engaged in excavation. The type of vehicle involved in the accident was a john deere 5075e tractor with a 7 ft. Mower. Since type of vehicle cannot be left blank for question 8, motorcycle/atv was selected as the best option. 5mph, motorcycle/atv, off road, 0 and "no" selected for questions 7 through 11 respectively at the recommendation of PHMSA aid to more clearly explain accidents of this nature caused by row mowing activities. |