HL incident on 2022-08-07 — CA

Operator
Crimson Pipeline L.p.
Cause
Corrosion Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$442,358
Incident datetime
2022-08-07 10:23
Report number
Location
CA
Narrative
On 07-07-2022 the control center received a call from a member of the public (jerry) giving notice he observed a black liquid on the shoulder of airport dr and merle haggard drive, bakersfield, ca. At the time the crimson pipeline in the area csfm #0420 12k140 was not operational but as a precaution the vales upstream and downstream were closed. Crimson control center dispatched operations to field verify the situation. The filed verified the presence of oil on the dirt shoulder of merle haggard drive. Osro's were dispatched to the release location. At the time the occ did not receive any leak alarms or observed any significant pressure drops or imbalances on csfm #0420 line segment.
Detailed record list
Report Received Date
2022-09-16 00:00:00
Iyear
2022
Report Number
20220215
Supplemental Number
38642
Report Type
Supplemental Final
Operator Id
Name
Crimson Pipeline L.p.
Operator Street Address
1900 Main Street Suite #600
Operator City Name
Irvine
Operator State Abbreviation
CA
Operator Postal Code
92614
Local Datetime
2022-08-07 10:34:00
Time Zone
Pacific
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
Commodity Released Type
Crude Oil
Unintentional Release Bbls
251
Recovered Bbls
251
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Notification From Public
Incident Identified Datetime
2022-08-07 10:23:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2022-08-07 09:41:00
Restart Datetime
2022-08-30 09:54:00
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Initial Responder Com Datetime
2022-08-07 10:34:00
On Site Datetime
2022-08-07 12:00:00
Confirmed Discovery Datetime
2022-08-07 10:23:00
Nrc Rpt Datetime
2022-08-07 10:34:00
Nrc Rpt Num
Additional Nrc Report Numbers
1344085
Ignite Ind
No
Upstream Action Taken
Valve Closure
Upstream Valve Close Datetime
2022-08-07 09:41:00
Upstream Valve Type Ind
Remotely Controlled
Downstream Action Taken
Valve Closure
Downstream Vlv Close Datetime
2022-08-07 10:15:00
Downstream Valve Type Ind
Manual
Notify Qualified Indiv Ind
Yes
Qualified Indiv Notif Datetime
2022-08-07 10:23:00
Oil Spill Removal Org Ind
Yes
Osro Activated Datetime
2022-08-07 10:23:00
Osro Arrived On Site Dt
8/7/2022 12:00
Num Pub Evacuated
0
Pipe Fac Name
Csfm 0420 12k140
Segment Name
Airport Blvd & Merle Haggard Drive
Onshore State Abbreviation
Ca
Onshore Postal Code
93308
Onshore City Name
Bakersfield
Onshore County Name
Kern
Designated Location
Milepost
Designated Name
Ili 2.55
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
72
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Pipe
Pipe Type
Pipe Body
Puddle Weld Ind
No
Pipe Diameter
12
Pipe Wall Thickness
0.25
Pipe Smys
52000
Pipe Specification
X52
Pipe Seam Type
Erw - High Frequency
Pipe Manufacturer
Unknown
Pipe Coating Type
Other
Pipe Coating Details
Polyethylene Tape Wrap Overcoated With An Epoxy Paint Coat
Coating Applied Ind
Yes
Installation Year
1980
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
Yes
High Pop Ind
Yes
High Pop Yes No
Yes
Usa Ecological Ind
Yes
Usa Ecological Yes No
Yes
Est Cost Oper Paid
0
Est Cost Gas Released
24751
Est Cost Prop Damage
442358
Est Cost Emergency
689460
Est Cost Environmental
0
Est Cost Other
0
Prpty
1156569
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
0
Mop Psig
964
Mop Cfr Section
Subpart E Pressure Test �195.406(A)(3)
Maop Established Date
1995-06-07 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
14926
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
No
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
Yes, specify investigation result(s): (select all that apply)
Invest No Control Room Ind
Yes
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
External Corrosion
Internal External
External Corrosion
Visual Exam Results
Localized Pitting
Atmosphere Corrosion Ind
Yes
Field Exam Basis Ind
Yes
Underground Location
Yes
Under Cathodic Protection Ind
Yes
Cathodic Pro Start Year
1995
Shielding Evident
Yes
Cathodic Survey Type
Yes
Cp Annual Survey Ind
Yes
Cp Annual Survey Year
2021
Prior Damage
Yes
Collected Data Ind
Yes
Axial Magnetic Flx Lkg Ind
Yes
Geometry Deformation Ind
Yes
Axial Recent Year
2021
Axial Rcnt Propul Method
Free Swimming
Axial Rcnt Attuned Detect
Metal Loss
Axial Rcnt Atnd Dtct Metal
High Resolution
Axial Previous Year
2018
Axial Prev Propul Method
Free Swimming
Axial Prev Attuned Detect
Metal Loss
Axial Prev Atnd Dtct Metal
Standard Resolution
Geometry Recent Year
2021
Geometry Rcnt Propul Method
Free Swimming
Geometry Rcnt Resolution
High Resolution
Geometrt Rcnt Measur Cups
No Cups
Geometry Previous Year
2018
Geometry Prev Propul Method
Free Swimming
Geometry Prev Resolution
Standard Resolution
Geometrt Prev Measur Cups
No Cups
Has Hydrtst Conduc Before Ind
Yes
Hydrtst Most Rcnt Year
1995
Hydrtst Most Rcnt Pressure
1310
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Extrnl Cor Atmospheric Ind
Yes
Preparer Name
D**** B********
Preparer Title
Regulatory Compliance Manager
Preparer Email
D*********@c********.com
Preparer Telephone
(562) 668-0066
Preparer Fax
(562) 285-4141
Prepared Date
2023-10-10 00:00:00
Local Contact Name
D**** B********
Local Contact Email
B**************@y****.com
Local Contact Telephone
(562) 668-0066
Authorizer Name
M**** K*******
Authorizer Telephone
(562)285-4137
Authorizer Title
President
Authorizer Email
M********@c********.com
Narrative
On 07-07-2022 the control center received a call from a member of the public (jerry) giving notice he observed a black liquid on the shoulder of airport dr and merle haggard drive, bakersfield, ca. At the time the crimson pipeline in the area csfm #0420 12k140 was not operational but as a precaution the vales upstream and downstream were closed. Crimson control center dispatched operations to field verify the situation. The filed verified the presence of oil on the dirt shoulder of merle haggard drive. Osro's were dispatched to the release location. At the time the occ did not receive any leak alarms or observed any significant pressure drops or imbalances on csfm #0420 line segment.
Report Received Date 2022-09-16 00:00:00
Iyear 2022
Report Number 20220215
Supplemental Number 38642
Report Type Supplemental Final
Operator Id 32103 PHMSA Enforcement
Name Crimson Pipeline L.p.
Operator Street Address 1900 Main Street Suite #600
Operator City Name Irvine
Operator State Abbreviation CA
Operator Postal Code 92614
Local Datetime 2022-08-07 10:34:00
Time Zone Pacific
Daylight Savings Ind Yes
Location Latitude 35.4413 Google Maps OpenStreetMap
Location Longitude -119.047584 Google Maps OpenStreetMap
Commodity Released Type Crude Oil
Unintentional Release Bbls 251
Recovered Bbls 251
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Notification From Public
Incident Identified Datetime 2022-08-07 10:23:00
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Status When Identified Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind Yes
Shutdown Datetime 2022-08-07 09:41:00
Restart Datetime 2022-08-30 09:54:00
Communication State Fed Ind Yes
Party Initiated Communication Operator
Initial Responder Com Datetime 2022-08-07 10:34:00
On Site Datetime 2022-08-07 12:00:00
Confirmed Discovery Datetime 2022-08-07 10:23:00
Nrc Rpt Datetime 2022-08-07 10:34:00
Nrc Rpt Num 1343781 NRC Report How to search
Additional Nrc Report Numbers 1344085
Ignite Ind No
Upstream Action Taken Valve Closure
Upstream Valve Close Datetime 2022-08-07 09:41:00
Upstream Valve Type Ind Remotely Controlled
Downstream Action Taken Valve Closure
Downstream Vlv Close Datetime 2022-08-07 10:15:00
Downstream Valve Type Ind Manual
Notify Qualified Indiv Ind Yes
Qualified Indiv Notif Datetime 2022-08-07 10:23:00
Oil Spill Removal Org Ind Yes
Osro Activated Datetime 2022-08-07 10:23:00
Osro Arrived On Site Dt 8/7/2022 12:00
Num Pub Evacuated 0
Pipe Fac Name Csfm 0420 12k140
Segment Name Airport Blvd & Merle Haggard Drive
Onshore State Abbreviation Ca
Onshore Postal Code 93308
Onshore City Name Bakersfield
Onshore County Name Kern
Designated Location Milepost
Designated Name Ili 2.55
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 72
Crossing No
Pipe Facility Type Intrastate
Item Involved Pipe
Pipe Type Pipe Body
Puddle Weld Ind No
Pipe Diameter 12
Pipe Wall Thickness 0.25
Pipe Smys 52000
Pipe Specification X52
Pipe Seam Type Erw - High Frequency
Pipe Manufacturer Unknown
Pipe Coating Type Other
Pipe Coating Details Polyethylene Tape Wrap Overcoated With An Epoxy Paint Coat
Coating Applied Ind Yes
Installation Year 1980
Manufactured Year Unknown
Material Involved Carbon Steel
Release Type Leak
Leak Type Pinhole
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment No
Remediation Ind No
Water Contam Ind No
Could Be Hca Yes
Commodity Reached Hca Yes
High Pop Ind Yes
High Pop Yes No Yes
Usa Ecological Ind Yes
Usa Ecological Yes No Yes
Est Cost Oper Paid 0
Est Cost Gas Released 24751
Est Cost Prop Damage 442358
Est Cost Emergency 689460
Est Cost Environmental 0
Est Cost Other 0
Prpty 1156569
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Accident Psig 0
Mop Psig 964
Mop Cfr Section Subpart E Pressure Test �195.406(A)(3) View CFR 49 §192
Maop Established Date 1995-06-07 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Length Segment Isolated 14926
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind No
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Cpm In Place Ind No
Investigation Status Yes, specify investigation result(s): (select all that apply)
Invest No Control Room Ind Yes
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Corrosion Failure
Cause Details External Corrosion
Internal External External Corrosion
Visual Exam Results Localized Pitting
Atmosphere Corrosion Ind Yes
Field Exam Basis Ind Yes
Underground Location Yes
Under Cathodic Protection Ind Yes
Cathodic Pro Start Year 1995
Shielding Evident Yes
Cathodic Survey Type Yes
Cp Annual Survey Ind Yes
Cp Annual Survey Year 2021
Prior Damage Yes
Collected Data Ind Yes
Axial Magnetic Flx Lkg Ind Yes
Geometry Deformation Ind Yes
Axial Recent Year 2021
Axial Rcnt Propul Method Free Swimming
Axial Rcnt Attuned Detect Metal Loss
Axial Rcnt Atnd Dtct Metal High Resolution
Axial Previous Year 2018
Axial Prev Propul Method Free Swimming
Axial Prev Attuned Detect Metal Loss
Axial Prev Atnd Dtct Metal Standard Resolution
Geometry Recent Year 2021
Geometry Rcnt Propul Method Free Swimming
Geometry Rcnt Resolution High Resolution
Geometrt Rcnt Measur Cups No Cups
Geometry Previous Year 2018
Geometry Prev Propul Method Free Swimming
Geometry Prev Resolution Standard Resolution
Geometrt Prev Measur Cups No Cups
Has Hydrtst Conduc Before Ind Yes
Hydrtst Most Rcnt Year 1995
Hydrtst Most Rcnt Pressure 1310
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Extrnl Cor Atmospheric Ind Yes
Preparer Name D**** B********
Preparer Title Regulatory Compliance Manager
Preparer Email D*********@c********.com
Preparer Telephone (562) 668-0066
Preparer Fax (562) 285-4141
Prepared Date 2023-10-10 00:00:00
Local Contact Name D**** B********
Local Contact Email B**************@y****.com
Local Contact Telephone (562) 668-0066
Authorizer Name M**** K*******
Authorizer Telephone (562)285-4137
Authorizer Title President
Authorizer Email M********@c********.com
Narrative On 07-07-2022 the control center received a call from a member of the public (jerry) giving notice he observed a black liquid on the shoulder of airport dr and merle haggard drive, bakersfield, ca. At the time the crimson pipeline in the area csfm #0420 12k140 was not operational but as a precaution the vales upstream and downstream were closed. Crimson control center dispatched operations to field verify the situation. The filed verified the presence of oil on the dirt shoulder of merle haggard drive. Osro's were dispatched to the release location. At the time the occ did not receive any leak alarms or observed any significant pressure drops or imbalances on csfm #0420 line segment.

All rights reserved. Copyright © by ClearPHMSA