HL incident on 2022-08-07 — CA
Operator
Crimson Pipeline L.p.
Cause
Corrosion Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$442,358
Incident datetime
2022-08-07 10:23
Report number
Location
CA
Narrative
On 07-07-2022 the control center received a call from a member of the public (jerry) giving notice he observed a black liquid on the shoulder of airport dr and merle haggard drive, bakersfield, ca. At the time the crimson pipeline in the area csfm #0420 12k140 was not operational but as a precaution the vales upstream and downstream were closed. Crimson control center dispatched operations to field verify the situation. The filed verified the presence of oil on the dirt shoulder of merle haggard drive. Osro's were dispatched to the release location. At the time the occ did not receive any leak alarms or observed any significant pressure drops or imbalances on csfm #0420 line segment.
Detailed record list
Report Received Date
2022-09-16 00:00:00
Iyear
2022
Report Number
20220215
Supplemental Number
38642
Report Type
Supplemental Final
Operator Id
32103
Name
Crimson Pipeline L.p.
Operator Street Address
1900 Main Street Suite #600
Operator City Name
Irvine
Operator State Abbreviation
CA
Operator Postal Code
92614
Local Datetime
2022-08-07 10:34:00
Time Zone
Pacific
Daylight Savings Ind
Yes
Location Latitude
35.4413
Location Longitude
-119.047584
Commodity Released Type
Crude Oil
Unintentional Release Bbls
251
Recovered Bbls
251
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Notification From Public
Incident Identified Datetime
2022-08-07 10:23:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2022-08-07 09:41:00
Restart Datetime
2022-08-30 09:54:00
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Initial Responder Com Datetime
2022-08-07 10:34:00
On Site Datetime
2022-08-07 12:00:00
Confirmed Discovery Datetime
2022-08-07 10:23:00
Nrc Rpt Datetime
2022-08-07 10:34:00
Nrc Rpt Num
1343781
Additional Nrc Report Numbers
1344085
Ignite Ind
No
Upstream Action Taken
Valve Closure
Upstream Valve Close Datetime
2022-08-07 09:41:00
Upstream Valve Type Ind
Remotely Controlled
Downstream Action Taken
Valve Closure
Downstream Vlv Close Datetime
2022-08-07 10:15:00
Downstream Valve Type Ind
Manual
Notify Qualified Indiv Ind
Yes
Qualified Indiv Notif Datetime
2022-08-07 10:23:00
Oil Spill Removal Org Ind
Yes
Osro Activated Datetime
2022-08-07 10:23:00
Osro Arrived On Site Dt
8/7/2022 12:00
Num Pub Evacuated
0
Pipe Fac Name
Csfm 0420 12k140
Segment Name
Airport Blvd & Merle Haggard Drive
Onshore State Abbreviation
Ca
Onshore Postal Code
93308
Onshore City Name
Bakersfield
Onshore County Name
Kern
Designated Location
Milepost
Designated Name
Ili 2.55
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
72
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Pipe
Pipe Type
Pipe Body
Puddle Weld Ind
No
Pipe Diameter
12
Pipe Wall Thickness
0.25
Pipe Smys
52000
Pipe Specification
X52
Pipe Seam Type
Erw - High Frequency
Pipe Manufacturer
Unknown
Pipe Coating Type
Other
Pipe Coating Details
Polyethylene Tape Wrap Overcoated With An Epoxy Paint Coat
Coating Applied Ind
Yes
Installation Year
1980
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
Yes
High Pop Ind
Yes
High Pop Yes No
Yes
Usa Ecological Ind
Yes
Usa Ecological Yes No
Yes
Est Cost Oper Paid
0
Est Cost Gas Released
24751
Est Cost Prop Damage
442358
Est Cost Emergency
689460
Est Cost Environmental
0
Est Cost Other
0
Prpty
1156569
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
0
Mop Psig
964
Mop Cfr Section
Subpart E Pressure Test �195.406(A)(3)
Maop Established Date
1995-06-07 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
14926
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
No
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
Yes, specify investigation result(s): (select all that apply)
Invest No Control Room Ind
Yes
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
External Corrosion
Internal External
External Corrosion
Visual Exam Results
Localized Pitting
Atmosphere Corrosion Ind
Yes
Field Exam Basis Ind
Yes
Underground Location
Yes
Under Cathodic Protection Ind
Yes
Cathodic Pro Start Year
1995
Shielding Evident
Yes
Cathodic Survey Type
Yes
Cp Annual Survey Ind
Yes
Cp Annual Survey Year
2021
Prior Damage
Yes
Collected Data Ind
Yes
Axial Magnetic Flx Lkg Ind
Yes
Geometry Deformation Ind
Yes
Axial Recent Year
2021
Axial Rcnt Propul Method
Free Swimming
Axial Rcnt Attuned Detect
Metal Loss
Axial Rcnt Atnd Dtct Metal
High Resolution
Axial Previous Year
2018
Axial Prev Propul Method
Free Swimming
Axial Prev Attuned Detect
Metal Loss
Axial Prev Atnd Dtct Metal
Standard Resolution
Geometry Recent Year
2021
Geometry Rcnt Propul Method
Free Swimming
Geometry Rcnt Resolution
High Resolution
Geometrt Rcnt Measur Cups
No Cups
Geometry Previous Year
2018
Geometry Prev Propul Method
Free Swimming
Geometry Prev Resolution
Standard Resolution
Geometrt Prev Measur Cups
No Cups
Has Hydrtst Conduc Before Ind
Yes
Hydrtst Most Rcnt Year
1995
Hydrtst Most Rcnt Pressure
1310
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Extrnl Cor Atmospheric Ind
Yes
Preparer Name
D**** B********
Preparer Title
Regulatory Compliance Manager
Preparer Email
D*********@c********.com
Preparer Telephone
(562) 668-0066
Preparer Fax
(562) 285-4141
Prepared Date
2023-10-10 00:00:00
Local Contact Name
D**** B********
Local Contact Email
B**************@y****.com
Local Contact Telephone
(562) 668-0066
Authorizer Name
M**** K*******
Authorizer Telephone
(562)285-4137
Authorizer Title
President
Authorizer Email
M********@c********.com
Narrative
On 07-07-2022 the control center received a call from a member of the public (jerry) giving notice he observed a black liquid on the shoulder of airport dr and merle haggard drive, bakersfield, ca. At the time the crimson pipeline in the area csfm #0420 12k140 was not operational but as a precaution the vales upstream and downstream were closed. Crimson control center dispatched operations to field verify the situation. The filed verified the presence of oil on the dirt shoulder of merle haggard drive. Osro's were dispatched to the release location. At the time the occ did not receive any leak alarms or observed any significant pressure drops or imbalances on csfm #0420 line segment.
| Report Received Date | 2022-09-16 00:00:00 |
|---|---|
| Iyear | 2022 |
| Report Number | 20220215 |
| Supplemental Number | 38642 |
| Report Type | Supplemental Final |
| Operator Id | 32103 PHMSA Enforcement |
| Name | Crimson Pipeline L.p. |
| Operator Street Address | 1900 Main Street Suite #600 |
| Operator City Name | Irvine |
| Operator State Abbreviation | CA |
| Operator Postal Code | 92614 |
| Local Datetime | 2022-08-07 10:34:00 |
| Time Zone | Pacific |
| Daylight Savings Ind | Yes |
| Location Latitude | 35.4413 Google Maps OpenStreetMap |
| Location Longitude | -119.047584 Google Maps OpenStreetMap |
| Commodity Released Type | Crude Oil |
| Unintentional Release Bbls | 251 |
| Recovered Bbls | 251 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Notification From Public |
| Incident Identified Datetime | 2022-08-07 10:23:00 |
| System Part Involved | Onshore Pipeline, Including Valve Sites |
| On Off Shore | Onshore |
| Status When Identified | Normal Operation, Includes Pauses Between Batches And During Maintenance |
| Shutdown Due Accident Ind | Yes |
| Shutdown Datetime | 2022-08-07 09:41:00 |
| Restart Datetime | 2022-08-30 09:54:00 |
| Communication State Fed Ind | Yes |
| Party Initiated Communication | Operator |
| Initial Responder Com Datetime | 2022-08-07 10:34:00 |
| On Site Datetime | 2022-08-07 12:00:00 |
| Confirmed Discovery Datetime | 2022-08-07 10:23:00 |
| Nrc Rpt Datetime | 2022-08-07 10:34:00 |
| Nrc Rpt Num | 1343781 NRC Report How to search |
| Additional Nrc Report Numbers | 1344085 |
| Ignite Ind | No |
| Upstream Action Taken | Valve Closure |
| Upstream Valve Close Datetime | 2022-08-07 09:41:00 |
| Upstream Valve Type Ind | Remotely Controlled |
| Downstream Action Taken | Valve Closure |
| Downstream Vlv Close Datetime | 2022-08-07 10:15:00 |
| Downstream Valve Type Ind | Manual |
| Notify Qualified Indiv Ind | Yes |
| Qualified Indiv Notif Datetime | 2022-08-07 10:23:00 |
| Oil Spill Removal Org Ind | Yes |
| Osro Activated Datetime | 2022-08-07 10:23:00 |
| Osro Arrived On Site Dt | 8/7/2022 12:00 |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Csfm 0420 12k140 |
| Segment Name | Airport Blvd & Merle Haggard Drive |
| Onshore State Abbreviation | Ca |
| Onshore Postal Code | 93308 |
| Onshore City Name | Bakersfield |
| Onshore County Name | Kern |
| Designated Location | Milepost |
| Designated Name | Ili 2.55 |
| Federal | No |
| Location Type | Pipeline Right-Of-Way |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Soil |
| Depth Of Cover | 72 |
| Crossing | No |
| Pipe Facility Type | Intrastate |
| Item Involved | Pipe |
| Pipe Type | Pipe Body |
| Puddle Weld Ind | No |
| Pipe Diameter | 12 |
| Pipe Wall Thickness | 0.25 |
| Pipe Smys | 52000 |
| Pipe Specification | X52 |
| Pipe Seam Type | Erw - High Frequency |
| Pipe Manufacturer | Unknown |
| Pipe Coating Type | Other |
| Pipe Coating Details | Polyethylene Tape Wrap Overcoated With An Epoxy Paint Coat |
| Coating Applied Ind | Yes |
| Installation Year | 1980 |
| Manufactured Year | Unknown |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Pinhole |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | No |
| Remediation Ind | No |
| Water Contam Ind | No |
| Could Be Hca | Yes |
| Commodity Reached Hca | Yes |
| High Pop Ind | Yes |
| High Pop Yes No | Yes |
| Usa Ecological Ind | Yes |
| Usa Ecological Yes No | Yes |
| Est Cost Oper Paid | 0 |
| Est Cost Gas Released | 24751 |
| Est Cost Prop Damage | 442358 |
| Est Cost Emergency | 689460 |
| Est Cost Environmental | 0 |
| Est Cost Other | 0 |
| Prpty | 1156569 |
| Num Persons Hosp Not Ovnght | 0 |
| Num Injured Treated By Emt | 0 |
| Num Resident Building Affctd | 0 |
| Num Business Building Affctd | 0 |
| Accident Psig | 0 |
| Mop Psig | 964 |
| Mop Cfr Section | Subpart E Pressure Test �195.406(A)(3) View CFR 49 §192 |
| Maop Established Date | 1995-06-07 00:00:00 |
| Maop Reversal Flow Ind | No |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Length Segment Isolated | 14926 |
| Internal Inspection Ind | Yes |
| Operation Complications Ind | No |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | No |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | No |
| Cpm In Place Ind | No |
| Investigation Status | Yes, specify investigation result(s): (select all that apply) |
| Invest No Control Room Ind | Yes |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Corrosion Failure |
| Cause Details | External Corrosion |
| Internal External | External Corrosion |
| Visual Exam Results | Localized Pitting |
| Atmosphere Corrosion Ind | Yes |
| Field Exam Basis Ind | Yes |
| Underground Location | Yes |
| Under Cathodic Protection Ind | Yes |
| Cathodic Pro Start Year | 1995 |
| Shielding Evident | Yes |
| Cathodic Survey Type | Yes |
| Cp Annual Survey Ind | Yes |
| Cp Annual Survey Year | 2021 |
| Prior Damage | Yes |
| Collected Data Ind | Yes |
| Axial Magnetic Flx Lkg Ind | Yes |
| Geometry Deformation Ind | Yes |
| Axial Recent Year | 2021 |
| Axial Rcnt Propul Method | Free Swimming |
| Axial Rcnt Attuned Detect | Metal Loss |
| Axial Rcnt Atnd Dtct Metal | High Resolution |
| Axial Previous Year | 2018 |
| Axial Prev Propul Method | Free Swimming |
| Axial Prev Attuned Detect | Metal Loss |
| Axial Prev Atnd Dtct Metal | Standard Resolution |
| Geometry Recent Year | 2021 |
| Geometry Rcnt Propul Method | Free Swimming |
| Geometry Rcnt Resolution | High Resolution |
| Geometrt Rcnt Measur Cups | No Cups |
| Geometry Previous Year | 2018 |
| Geometry Prev Propul Method | Free Swimming |
| Geometry Prev Resolution | Standard Resolution |
| Geometrt Prev Measur Cups | No Cups |
| Has Hydrtst Conduc Before Ind | Yes |
| Hydrtst Most Rcnt Year | 1995 |
| Hydrtst Most Rcnt Pressure | 1310 |
| Direct Asmnt Conducted | No |
| Non Destructive Exam Ind | No |
| Extrnl Cor Atmospheric Ind | Yes |
| Preparer Name | D**** B******** |
| Preparer Title | Regulatory Compliance Manager |
| Preparer Email | D*********@c********.com |
| Preparer Telephone | (562) 668-0066 |
| Preparer Fax | (562) 285-4141 |
| Prepared Date | 2023-10-10 00:00:00 |
| Local Contact Name | D**** B******** |
| Local Contact Email | B**************@y****.com |
| Local Contact Telephone | (562) 668-0066 |
| Authorizer Name | M**** K******* |
| Authorizer Telephone | (562)285-4137 |
| Authorizer Title | President |
| Authorizer Email | M********@c********.com |
| Narrative | On 07-07-2022 the control center received a call from a member of the public (jerry) giving notice he observed a black liquid on the shoulder of airport dr and merle haggard drive, bakersfield, ca. At the time the crimson pipeline in the area csfm #0420 12k140 was not operational but as a precaution the vales upstream and downstream were closed. Crimson control center dispatched operations to field verify the situation. The filed verified the presence of oil on the dirt shoulder of merle haggard drive. Osro's were dispatched to the release location. At the time the occ did not receive any leak alarms or observed any significant pressure drops or imbalances on csfm #0420 line segment. |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company
All rights reserved. Copyright © by ClearPHMSA