HL incident on 2022-08-17 — TX
Operator
Enterprise Products Operating Llc
Cause
Incorrect Operation
Commodity
Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$0
Incident datetime
2022-08-17 07:05
Report number
Location
TX
Narrative
On 8/17/22, at 7:05 am, contractors notified enterprise of a leak inside the channel meter station. At 07:15 am, enterprise personnel arrived on site and confirmed the leak was on the channel 8" line. At 08:05 am, the emergency response team arrived with the required personal protective equipment needed to enter the site. At 08:15 am, the leak source was identified to be a pressure gauge on piping installed for the ili assessment. A valve upstream was closed, ending the release. The pressure gauge was removed and replaced with a plug. At 07:50 am, enterprise determined the leak volume exceeded 5 gallons and notified the trrc at 08:29 am, incident report number 2685. Nrc reporting criteria was not met. Investigation of the failure concluded that the pressure gauge had a lower pressure scale range than the pipeline's operating pressure. The pressure gauge failed upon exceedance of its top range of 600 psig. The contractor did not conduct a drug or alcohol test as the pressure gauge was installed 38 hours prior to the accident.
Detailed record list
Report Received Date
2022-09-16 00:00:00
Iyear
2022
Report Number
20220214
Supplemental Number
37232
Report Type
Supplemental Final
Operator Id
31618
Name
Enterprise Products Operating Llc
Operator Street Address
1100 Louisiana Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2022-08-17 07:05:00
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
29.689564
Location Longitude
-95.057092
Commodity Released Type
Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Commodity Subtype
Other Hvl
Commodity Details
Propylene
Unintentional Release Bbls
3.54
Intentional Release Bbls
0
Recovered Bbls
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Contractor Working For The Operator
Incident Identified Datetime
2022-08-17 07:05:00
System Part Involved
Onshore Pump/meter Station Equipment And Piping
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
No
Shutdown Explain
Leak Was Isolated Without Shutting Down The Pipeline.
Communication State Fed Ind
No
On Site Datetime
2022-08-17 07:15:00
Confirmed Discovery Datetime
2022-08-17 07:15:00
Nrc Rpt Num
Nrc Notification Not Required
Ignite Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Channel 8"
Segment Name
32694
Onshore State Abbreviation
Tx
Onshore Postal Code
77571
Onshore City Name
La Porte
Onshore County Name
Harris
Designated Location
Milepost
Designated Name
5.1
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Other
Item Involved Details
Pressure Gauge
Installation Year
Unknown
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Other
Leak Type Other
Pressure Gauge Failed
Wildlife Impact Ind
No
Soil Contamination
No
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
Yes
High Pop Ind
Yes
High Pop Yes No
Yes
Est Cost Oper Paid
0
Est Cost Gas Released
160
Est Cost Prop Damage
0
Est Cost Emergency
4200
Est Cost Environmental
0
Est Cost Other
0
Prpty
4360
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
605
Mop Psig
1440
Mop Cfr Section
Component Design Pressure �195.406(A)(2)
Maop Established Date
1982-12-30 00:00:00
Maop Reversal Flow Ind
Bi-Directional
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
The leak occurred on a pressure gauge.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Incorrect Operation
Cause Details
Wrong Equipment Specified Or Installed
Operation Type
Wrong Equipment Specified Or Installed
Related Failure Follow Ind
Yes
Category Type
Routine Maintenance
Operator Qualification Ind
Yes
Qualified Individuals
Yes, They Were Qualified For The Task(S)
Io Equipment Overpressure Ind
Yes
Preparer Name
M****** G*****
Preparer Title
Pipeline Compliance Engineer
Preparer Email
M******@e****.com
Preparer Telephone
713-381-4637
Prepared Date
2022-10-17 00:00:00
Authorizer Name
N*** T*****
Authorizer Telephone
713-381-2493
Authorizer Title
Compliance Senior Manager
Authorizer Email
N*******@e****.com
Narrative
On 8/17/22, at 7:05 am, contractors notified enterprise of a leak inside the channel meter station. At 07:15 am, enterprise personnel arrived on site and confirmed the leak was on the channel 8" line. At 08:05 am, the emergency response team arrived with the required personal protective equipment needed to enter the site. At 08:15 am, the leak source was identified to be a pressure gauge on piping installed for the ili assessment. A valve upstream was closed, ending the release. The pressure gauge was removed and replaced with a plug. At 07:50 am, enterprise determined the leak volume exceeded 5 gallons and notified the trrc at 08:29 am, incident report number 2685. Nrc reporting criteria was not met. Investigation of the failure concluded that the pressure gauge had a lower pressure scale range than the pipeline's operating pressure. The pressure gauge failed upon exceedance of its top range of 600 psig. The contractor did not conduct a drug or alcohol test as the pressure gauge was installed 38 hours prior to the accident.
| Report Received Date | 2022-09-16 00:00:00 |
|---|---|
| Iyear | 2022 |
| Report Number | 20220214 |
| Supplemental Number | 37232 |
| Report Type | Supplemental Final |
| Operator Id | 31618 PHMSA Enforcement |
| Name | Enterprise Products Operating Llc |
| Operator Street Address | 1100 Louisiana Street |
| Operator City Name | Houston |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77002 |
| Local Datetime | 2022-08-17 07:05:00 |
| Time Zone | Central |
| Daylight Savings Ind | Yes |
| Location Latitude | 29.689564 Google Maps OpenStreetMap |
| Location Longitude | -95.057092 Google Maps OpenStreetMap |
| Commodity Released Type | Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions |
| Commodity Subtype | Other Hvl |
| Commodity Details | Propylene |
| Unintentional Release Bbls | 3.54 |
| Intentional Release Bbls | 0 |
| Recovered Bbls | 0 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Local Operating Personnel, Including Contractors |
| Operator Type | Contractor Working For The Operator |
| Incident Identified Datetime | 2022-08-17 07:05:00 |
| System Part Involved | Onshore Pump/meter Station Equipment And Piping |
| On Off Shore | Onshore |
| Status When Identified | Normal Operation, Includes Pauses Between Batches And During Maintenance |
| Shutdown Due Accident Ind | No |
| Shutdown Explain | Leak Was Isolated Without Shutting Down The Pipeline. |
| Communication State Fed Ind | No |
| On Site Datetime | 2022-08-17 07:15:00 |
| Confirmed Discovery Datetime | 2022-08-17 07:15:00 |
| Nrc Rpt Num | Nrc Notification Not Required NRC Report How to search |
| Ignite Ind | No |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Channel 8" |
| Segment Name | 32694 |
| Onshore State Abbreviation | Tx |
| Onshore Postal Code | 77571 |
| Onshore City Name | La Porte |
| Onshore County Name | Harris |
| Designated Location | Milepost |
| Designated Name | 5.1 |
| Federal | No |
| Location Type | Totally Contained On Operator-Controlled Property |
| Incident Area Type | Aboveground |
| Incident Area Subtype | Typical Aboveground Facility Piping Or Appurtenance |
| Crossing | No |
| Pipe Facility Type | Intrastate |
| Item Involved | Other |
| Item Involved Details | Pressure Gauge |
| Installation Year | Unknown |
| Manufactured Year | Unknown |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Other |
| Leak Type Other | Pressure Gauge Failed |
| Wildlife Impact Ind | No |
| Soil Contamination | No |
| Long Term Assessment | No |
| Remediation Ind | No |
| Water Contam Ind | No |
| Could Be Hca | Yes |
| Commodity Reached Hca | Yes |
| High Pop Ind | Yes |
| High Pop Yes No | Yes |
| Est Cost Oper Paid | 0 |
| Est Cost Gas Released | 160 |
| Est Cost Prop Damage | 0 |
| Est Cost Emergency | 4200 |
| Est Cost Environmental | 0 |
| Est Cost Other | 0 |
| Prpty | 4360 |
| Num Persons Hosp Not Ovnght | 0 |
| Num Injured Treated By Emt | 0 |
| Num Resident Building Affctd | 0 |
| Num Business Building Affctd | 0 |
| Accident Psig | 605 |
| Mop Psig | 1440 |
| Mop Cfr Section | Component Design Pressure �195.406(A)(2) View CFR 49 §192 |
| Maop Established Date | 1982-12-30 00:00:00 |
| Maop Reversal Flow Ind | Bi-Directional |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | No |
| Cpm In Place Ind | Yes |
| Cpm Operating Ind | Yes |
| Cpm Functional Ind | Yes |
| Cpm Detection Ind | No |
| Cpm Conf Ind | No |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | The leak occurred on a pressure gauge. |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Incorrect Operation |
| Cause Details | Wrong Equipment Specified Or Installed |
| Operation Type | Wrong Equipment Specified Or Installed |
| Related Failure Follow Ind | Yes |
| Category Type | Routine Maintenance |
| Operator Qualification Ind | Yes |
| Qualified Individuals | Yes, They Were Qualified For The Task(S) |
| Io Equipment Overpressure Ind | Yes |
| Preparer Name | M****** G***** |
| Preparer Title | Pipeline Compliance Engineer |
| Preparer Email | M******@e****.com |
| Preparer Telephone | 713-381-4637 |
| Prepared Date | 2022-10-17 00:00:00 |
| Authorizer Name | N*** T***** |
| Authorizer Telephone | 713-381-2493 |
| Authorizer Title | Compliance Senior Manager |
| Authorizer Email | N*******@e****.com |
| Narrative | On 8/17/22, at 7:05 am, contractors notified enterprise of a leak inside the channel meter station. At 07:15 am, enterprise personnel arrived on site and confirmed the leak was on the channel 8" line. At 08:05 am, the emergency response team arrived with the required personal protective equipment needed to enter the site. At 08:15 am, the leak source was identified to be a pressure gauge on piping installed for the ili assessment. A valve upstream was closed, ending the release. The pressure gauge was removed and replaced with a plug. At 07:50 am, enterprise determined the leak volume exceeded 5 gallons and notified the trrc at 08:29 am, incident report number 2685. Nrc reporting criteria was not met. Investigation of the failure concluded that the pressure gauge had a lower pressure scale range than the pipeline's operating pressure. The pressure gauge failed upon exceedance of its top range of 600 psig. The contractor did not conduct a drug or alcohol test as the pressure gauge was installed 38 hours prior to the accident. |