Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2022-07-26 — —
Operator
Casper Crude To Rail, Llc
Cause
Equipment Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$7,500
Incident datetime
2022-07-26 15:15
Report number
Location
—
Narrative
15:15 outside operator discovers seal fail while performing hourly inspections 15:16 outsider operator notifies board operator and board operator swaps pumps and shuts down p501 15:17 terminal manager notified by board operator of release 15:18 terminal director notified by tm 15:19 hsse director notified by tm 15:21 enserv notified by tm 15:20 outside operator notified site leader of release 15:22 melco called not available 15:25 badger called not availabe 15:30 granite peak supplies vac truck 15:31 enserv calls tm to discuss 15:43 enserv and tm determine release is PHMSA jurisdictional 16:08 granite peak vac truck arrives 17:00 pipe drained and leak stopped 17:30 oil pumped back into tank 18:15 vac truck leaves location 18:35 environmental director notified
Detailed record list
Report Received Date
2022-08-25 00:00:00
Iyear
2022
Report Number
20220194
Supplemental Number
37028
Report Type
Original Final
Operator Id
39050
Name
Casper Crude To Rail, Llc
Operator Street Address
3900-205, 5th Ave Sw
Operator City Name
Calgary
Operator Postal Code
T2p 2v7
Local Datetime
2022-07-26 15:15:00
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
42.94443
Location Longitude
-106.44152
Commodity Released Type
Crude Oil
Unintentional Release Bbls
1
Recovered Bbls
1
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Ground Patrol By Operator Or Its Contractor
Operator Type
Operator Employee
Incident Identified Datetime
2022-07-26 15:15:00
System Part Involved
Onshore Pump/meter Station Equipment And Piping
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
No
Shutdown Explain
Bypassed Mainline Pump Using Booster Pumps.
Communication State Fed Ind
No
On Site Datetime
2022-07-26 15:15:00
Confirmed Discovery Datetime
2022-07-26 15:15:00
Nrc Rpt Num
Nrc Notification Not Required
Ignite Ind
No
Notify Qualified Indiv Ind
No
Oil Spill Removal Org Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Casper Crude To Rail Terminal
Onshore State Abbreviation
Wy
Onshore Postal Code
82604
Onshore City Name
Casper
Onshore County Name
Natrona
Designated Location
Milepost
Designated Name
0
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Pump
Pump Type
Centrifugal
Pump Service Type
Mainline
Installation Year
2020
Manufactured Year
2020
Material Involved
Material Other Than Carbon Steel
Material Details
Butyl Rubber
Release Type
Leak
Leak Type
Seal Or Packing
Wildlife Impact Ind
No
Soil Contamination
No
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
100
Est Cost Prop Damage
7500
Est Cost Emergency
5000
Est Cost Environmental
0
Est Cost Other
0
Prpty
12600
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
40
Mop Psig
275
Mop Cfr Section
Other
Mop Cfr Section Details
Pump
Maop Established Date
2021-02-03 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
No
Cpm In Place Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
This was a mechanical failure.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Equipment Failure
Cause Details
Pump Or Pump-Related Equipment
Eq Failure Type
Pump Or Pump-Related Equipment
Other Pump Ind
Seal/packing Failure
Additional Breakdown Ind
Yes
Eqf Pump Equipment Ind
Yes
Preparer Name
C*** L*******
Preparer Title
Regulatory Compliance
Preparer Email
C***@e**************.com
Preparer Telephone
936-524-7714
Prepared Date
2022-08-25 00:00:00
Local Contact Name
L*** P*******
Local Contact Email
L********@u***.com
Local Contact Telephone
307-233-8542
Authorizer Name
R** P*******
Authorizer Telephone
281-291-3921
Authorizer Title
Hsse Director
Authorizer Email
R********@u***.com
Narrative
15:15 outside operator discovers seal fail while performing hourly inspections 15:16 outsider operator notifies board operator and board operator swaps pumps and shuts down p501 15:17 terminal manager notified by board operator of release 15:18 terminal director notified by tm 15:19 hsse director notified by tm 15:21 enserv notified by tm 15:20 outside operator notified site leader of release 15:22 melco called not available 15:25 badger called not availabe 15:30 granite peak supplies vac truck 15:31 enserv calls tm to discuss 15:43 enserv and tm determine release is PHMSA jurisdictional 16:08 granite peak vac truck arrives 17:00 pipe drained and leak stopped 17:30 oil pumped back into tank 18:15 vac truck leaves location 18:35 environmental director notified
| Report Received Date | 2022-08-25 00:00:00 |
|---|---|
| Iyear | 2022 |
| Report Number | 20220194 |
| Supplemental Number | 37028 |
| Report Type | Original Final |
| Operator Id | 39050 PHMSA Enforcement |
| Name | Casper Crude To Rail, Llc |
| Operator Street Address | 3900-205, 5th Ave Sw |
| Operator City Name | Calgary |
| Operator Postal Code | T2p 2v7 |
| Local Datetime | 2022-07-26 15:15:00 |
| Time Zone | Central |
| Daylight Savings Ind | Yes |
| Location Latitude | 42.94443 Google Maps OpenStreetMap |
| Location Longitude | -106.44152 Google Maps OpenStreetMap |
| Commodity Released Type | Crude Oil |
| Unintentional Release Bbls | 1 |
| Recovered Bbls | 1 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Ground Patrol By Operator Or Its Contractor |
| Operator Type | Operator Employee |
| Incident Identified Datetime | 2022-07-26 15:15:00 |
| System Part Involved | Onshore Pump/meter Station Equipment And Piping |
| On Off Shore | Onshore |
| Status When Identified | Normal Operation, Includes Pauses Between Batches And During Maintenance |
| Shutdown Due Accident Ind | No |
| Shutdown Explain | Bypassed Mainline Pump Using Booster Pumps. |
| Communication State Fed Ind | No |
| On Site Datetime | 2022-07-26 15:15:00 |
| Confirmed Discovery Datetime | 2022-07-26 15:15:00 |
| Nrc Rpt Num | Nrc Notification Not Required NRC Report How to search |
| Ignite Ind | No |
| Notify Qualified Indiv Ind | No |
| Oil Spill Removal Org Ind | No |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Casper Crude To Rail Terminal |
| Onshore State Abbreviation | Wy |
| Onshore Postal Code | 82604 |
| Onshore City Name | Casper |
| Onshore County Name | Natrona |
| Designated Location | Milepost |
| Designated Name | 0 |
| Federal | No |
| Location Type | Totally Contained On Operator-Controlled Property |
| Incident Area Type | Aboveground |
| Incident Area Subtype | Typical Aboveground Facility Piping Or Appurtenance |
| Crossing | No |
| Pipe Facility Type | Intrastate |
| Item Involved | Pump |
| Pump Type | Centrifugal |
| Pump Service Type | Mainline |
| Installation Year | 2020 |
| Manufactured Year | 2020 |
| Material Involved | Material Other Than Carbon Steel |
| Material Details | Butyl Rubber |
| Release Type | Leak |
| Leak Type | Seal Or Packing |
| Wildlife Impact Ind | No |
| Soil Contamination | No |
| Long Term Assessment | No |
| Remediation Ind | No |
| Water Contam Ind | No |
| Could Be Hca | No |
| Commodity Reached Hca | No |
| Est Cost Oper Paid | 0 |
| Est Cost Gas Released | 100 |
| Est Cost Prop Damage | 7500 |
| Est Cost Emergency | 5000 |
| Est Cost Environmental | 0 |
| Est Cost Other | 0 |
| Prpty | 12600 |
| Num Persons Hosp Not Ovnght | 0 |
| Num Injured Treated By Emt | 0 |
| Num Resident Building Affctd | 0 |
| Num Business Building Affctd | 0 |
| Accident Psig | 40 |
| Mop Psig | 275 |
| Mop Cfr Section | Other View CFR 49 §192 |
| Mop Cfr Section Details | Pump |
| Maop Established Date | 2021-02-03 00:00:00 |
| Maop Reversal Flow Ind | No |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | No |
| Cpm In Place Ind | No |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | This was a mechanical failure. |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Equipment Failure |
| Cause Details | Pump Or Pump-Related Equipment |
| Eq Failure Type | Pump Or Pump-Related Equipment |
| Other Pump Ind | Seal/packing Failure |
| Additional Breakdown Ind | Yes |
| Eqf Pump Equipment Ind | Yes |
| Preparer Name | C*** L******* |
| Preparer Title | Regulatory Compliance |
| Preparer Email | C***@e**************.com |
| Preparer Telephone | 936-524-7714 |
| Prepared Date | 2022-08-25 00:00:00 |
| Local Contact Name | L*** P******* |
| Local Contact Email | L********@u***.com |
| Local Contact Telephone | 307-233-8542 |
| Authorizer Name | R** P******* |
| Authorizer Telephone | 281-291-3921 |
| Authorizer Title | Hsse Director |
| Authorizer Email | R********@u***.com |
| Narrative | 15:15 outside operator discovers seal fail while performing hourly inspections 15:16 outsider operator notifies board operator and board operator swaps pumps and shuts down p501 15:17 terminal manager notified by board operator of release 15:18 terminal director notified by tm 15:19 hsse director notified by tm 15:21 enserv notified by tm 15:20 outside operator notified site leader of release 15:22 melco called not available 15:25 badger called not availabe 15:30 granite peak supplies vac truck 15:31 enserv calls tm to discuss 15:43 enserv and tm determine release is PHMSA jurisdictional 16:08 granite peak vac truck arrives 17:00 pipe drained and leak stopped 17:30 oil pumped back into tank 18:15 vac truck leaves location 18:35 environmental director notified |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company
All rights reserved. Copyright © by ClearPHMSA