HL incident on 2022-07-13 — OK

Operator
Medallion Operating Company, Llc
Cause
Equipment Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$30
Incident datetime
2022-07-13 08:30
Report number
Location
OK
Narrative
On wednesday, july 13, 2022, at approximately 08:34, the medallion control room received several alarms from the oems station after a portion of the flow into the station from an adjacent facility operated by another pipeline operator suddenly stopped. When the flow stopped, it caused a vibration in the system and triggered the non-critical alarms. The control room operators immediately acknowledged the alarms, viewed the closed-circuit surveillance camera at the facility and found what appeared to be an oil leak near pump #26520. The controllers then shut down the oems station and dispatched medallion field operations personnel to the site to investigate. The investigation indicates that the flange connection on the discharge control valve off of pump #26520 was leaking. Medallion operations installed a new gasket, torqued the bolts to specification, and returned the station back to normal operations at 11:03 am. Remediation of the affected soil was completed on tuesday, august 9, 2022.
Detailed record list
Report Received Date
2022-08-10 00:00:00
Iyear
2022
Report Number
20220177
Supplemental Number
36965
Report Type
Original Final
Operator Id
Name
Medallion Operating Company, Llc
Operator Street Address
100 W Fifth Street
Operator City Name
Tulsa
Operator State Abbreviation
OK
Operator Postal Code
74103
Local Datetime
2022-07-13 10:00:00
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
Commodity Released Type
Crude Oil
Unintentional Release Bbls
0.8
Recovered Bbls
0.8
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Controller
Operator Type
Operator Employee
Incident Identified Datetime
2022-07-13 08:30:00
System Part Involved
Onshore Pump/meter Station Equipment And Piping
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2022-07-13 08:30:00
Restart Datetime
2022-07-13 11:03:00
Communication State Fed Ind
No
On Site Datetime
2022-07-13 09:50:00
Confirmed Discovery Datetime
2022-07-13 10:00:00
Nrc Rpt Num
Nrc Notification Not Required
Ignite Ind
No
Notify Qualified Indiv Ind
No
Oil Spill Removal Org Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Omes
Segment Name
Mar16-1000
Onshore State Abbreviation
Tx
Onshore Postal Code
79782
Onshore City Name
Midland
Onshore County Name
Martin
Designated Location
Survey Station No.
Designated Name
0+00
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Flange Assembly
Installation Year
2019
Manufactured Year
2019
Material Involved
Material Other Than Carbon Steel
Material Details
Spiral Wound Metal Gasket
Release Type
Leak
Leak Type
Connection Failure
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
70
Est Cost Prop Damage
30
Est Cost Emergency
12500
Est Cost Environmental
0
Est Cost Other
0
Prpty
12600
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
700
Mop Psig
1440
Mop Cfr Section
Component Design Pressure �195.406(A)(2)
Maop Established Date
2019-10-03 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
Yes
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
The control room received non-critical alarms. Control room operators immediately acknowledged the alarms, viewed the closed-circuit surveillance camera at the facility, and found what appeared to be an oil leak near pump #26520 and shut the station down.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Equipment Failure
Cause Details
Non-Threaded Connection Failure
Eq Failure Type
Non-Threaded Connection Failure
Other Non Threaded Ind
Gasket
Additional Vibration Ind
Yes
Preparer Name
G*** B*****
Preparer Title
Ehs Manager
Preparer Email
G******@m*****************.com
Preparer Telephone
4325532184
Prepared Date
2022-08-10 00:00:00
Local Contact Name
G*** B*****
Local Contact Email
G******@m*****************.com
Local Contact Telephone
4325532184
Authorizer Name
G*** B*****
Authorizer Telephone
4325532184
Authorizer Title
Ehs Manager
Authorizer Email
G******@m*****************.com
Narrative
On wednesday, july 13, 2022, at approximately 08:34, the medallion control room received several alarms from the oems station after a portion of the flow into the station from an adjacent facility operated by another pipeline operator suddenly stopped. When the flow stopped, it caused a vibration in the system and triggered the non-critical alarms. The control room operators immediately acknowledged the alarms, viewed the closed-circuit surveillance camera at the facility and found what appeared to be an oil leak near pump #26520. The controllers then shut down the oems station and dispatched medallion field operations personnel to the site to investigate. The investigation indicates that the flange connection on the discharge control valve off of pump #26520 was leaking. Medallion operations installed a new gasket, torqued the bolts to specification, and returned the station back to normal operations at 11:03 am. Remediation of the affected soil was completed on tuesday, august 9, 2022.
Report Received Date 2022-08-10 00:00:00
Iyear 2022
Report Number 20220177
Supplemental Number 36965
Report Type Original Final
Operator Id 39183 PHMSA Enforcement
Name Medallion Operating Company, Llc
Operator Street Address 100 W Fifth Street
Operator City Name Tulsa
Operator State Abbreviation OK
Operator Postal Code 74103
Local Datetime 2022-07-13 10:00:00
Time Zone Central
Daylight Savings Ind Yes
Location Latitude 32.221238 Google Maps OpenStreetMap
Location Longitude -102.086441 Google Maps OpenStreetMap
Commodity Released Type Crude Oil
Unintentional Release Bbls 0.8
Recovered Bbls 0.8
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Controller
Operator Type Operator Employee
Incident Identified Datetime 2022-07-13 08:30:00
System Part Involved Onshore Pump/meter Station Equipment And Piping
On Off Shore Onshore
Status When Identified Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind Yes
Shutdown Datetime 2022-07-13 08:30:00
Restart Datetime 2022-07-13 11:03:00
Communication State Fed Ind No
On Site Datetime 2022-07-13 09:50:00
Confirmed Discovery Datetime 2022-07-13 10:00:00
Nrc Rpt Num Nrc Notification Not Required NRC Report How to search
Ignite Ind No
Notify Qualified Indiv Ind No
Oil Spill Removal Org Ind No
Num Pub Evacuated 0
Pipe Fac Name Omes
Segment Name Mar16-1000
Onshore State Abbreviation Tx
Onshore Postal Code 79782
Onshore City Name Midland
Onshore County Name Martin
Designated Location Survey Station No.
Designated Name 0+00
Federal No
Location Type Totally Contained On Operator-Controlled Property
Incident Area Type Aboveground
Incident Area Subtype Typical Aboveground Facility Piping Or Appurtenance
Crossing No
Pipe Facility Type Intrastate
Item Involved Flange Assembly
Installation Year 2019
Manufactured Year 2019
Material Involved Material Other Than Carbon Steel
Material Details Spiral Wound Metal Gasket
Release Type Leak
Leak Type Connection Failure
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment No
Remediation Ind No
Water Contam Ind No
Could Be Hca No
Commodity Reached Hca No
Est Cost Oper Paid 0
Est Cost Gas Released 70
Est Cost Prop Damage 30
Est Cost Emergency 12500
Est Cost Environmental 0
Est Cost Other 0
Prpty 12600
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Accident Psig 700
Mop Psig 1440
Mop Cfr Section Component Design Pressure �195.406(A)(2) View CFR 49 §192
Maop Established Date 2019-10-03 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind Yes
Scada Conf Ind No
Cpm In Place Ind No
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details The control room received non-critical alarms. Control room operators immediately acknowledged the alarms, viewed the closed-circuit surveillance camera at the facility, and found what appeared to be an oil leak near pump #26520 and shut the station down.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Equipment Failure
Cause Details Non-Threaded Connection Failure
Eq Failure Type Non-Threaded Connection Failure
Other Non Threaded Ind Gasket
Additional Vibration Ind Yes
Preparer Name G*** B*****
Preparer Title Ehs Manager
Preparer Email G******@m*****************.com
Preparer Telephone 4325532184
Prepared Date 2022-08-10 00:00:00
Local Contact Name G*** B*****
Local Contact Email G******@m*****************.com
Local Contact Telephone 4325532184
Authorizer Name G*** B*****
Authorizer Telephone 4325532184
Authorizer Title Ehs Manager
Authorizer Email G******@m*****************.com
Narrative On wednesday, july 13, 2022, at approximately 08:34, the medallion control room received several alarms from the oems station after a portion of the flow into the station from an adjacent facility operated by another pipeline operator suddenly stopped. When the flow stopped, it caused a vibration in the system and triggered the non-critical alarms. The control room operators immediately acknowledged the alarms, viewed the closed-circuit surveillance camera at the facility and found what appeared to be an oil leak near pump #26520. The controllers then shut down the oems station and dispatched medallion field operations personnel to the site to investigate. The investigation indicates that the flange connection on the discharge control valve off of pump #26520 was leaking. Medallion operations installed a new gasket, torqued the bolts to specification, and returned the station back to normal operations at 11:03 am. Remediation of the affected soil was completed on tuesday, august 9, 2022.