Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2022-07-09 — TX
Operator
Kinder Morgan Crude And Condensate Llc
Cause
Equipment Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$1,500
Incident datetime
2022-07-09 09:20
Report number
Location
TX
Narrative
On july 9, 2022, at approximately 08:30 cst, kinder morgan crude and condensate (PHMSA opid #23678) local operations personnel received a telephone call from a landowner stating they smelled a petroleum odor near mainline block valve 90 located in wharton county tx, near the town of wharton. Local operations personnel contacted houston control center (hcc) to shut down the pipe. Operations personnel then began to travel to the reported location. Upon arrival at 09:20, crude oil was witnessed spilling from the interface system pump. The failed pump was isolated and the oil spill response plan was initiated. Based on an initial estimate, 69 gallons of crude oil released, the railroad commission of tx was notified telephonically at 09:58. The contracted osro arrived and began remediation activities. The gps coordinates were incorrect and updated on 9.8.22 at 0915. The failed pump was shipped to the manufacturer for failure analysis. The cause of the failure was determined to be failed snap rings. September 2022 update: total volume release updated from 69 gallons to 13 barrels. June 2024 update: submitting final report with administrative changes.
Detailed record list
Report Received Date
2022-08-08 00:00:00
Iyear
2022
Report Number
20220174
Supplemental Number
39631
Report Type
Supplemental Final
Operator Id
32678
Name
Kinder Morgan Crude And Condensate Llc
Operator Street Address
1001 Louisiana St., Suite 1000
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2022-07-09 00:50:00
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
29.244414
Location Longitude
-96.1036
Commodity Released Type
Crude Oil
Unintentional Release Bbls
13
Recovered Bbls
13
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Notification From Public
Incident Identified Datetime
2022-07-09 09:20:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2022-07-09 08:43:00
Restart Datetime
2022-07-09 14:08:00
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Initial Responder Com Datetime
2022-07-09 09:58:00
On Site Datetime
2022-07-09 09:20:00
Confirmed Discovery Datetime
2022-07-09 09:20:00
Nrc Rpt Num
Nrc Notification Not Required
Ignite Ind
No
Upstream Action Taken
Valve Closure
Upstream Valve Close Datetime
2022-07-09 09:35:00
Upstream Valve Type Ind
Manual
Downstream Action Taken
Valve Closure
Downstream Vlv Close Datetime
2022-07-09 09:35:00
Downstream Valve Type Ind
Manual
Notify Qualified Indiv Ind
Yes
Qualified Indiv Notif Datetime
2022-07-09 08:30:00
Oil Spill Removal Org Ind
Yes
Osro Activated Datetime
2022-07-09 09:30:00
Osro Arrived On Site Dt
7/9/2022 9:45
Num Pub Evacuated
0
Pipe Fac Name
Dewitt To Oil Tanking
Segment Name
30" Edna To Missouri City
Onshore State Abbreviation
Tx
Onshore Postal Code
77488
Onshore City Name
Wharton
Onshore County Name
Wharton
Designated Location
Milepost
Designated Name
89.59
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Pump
Pump Type
Positive Displacement
Pump Service Type
Injection
Installation Year
2018
Manufactured Year
2018
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Seal Or Packing
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
1316
Est Cost Prop Damage
1500
Est Cost Emergency
13880
Est Cost Environmental
32500
Est Cost Other
0
Prpty
49196
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
447
Mop Psig
780
Mop Cfr Section
Internal Design Pressure �195.406(A)(1)
Maop Established Date
2012-10-05 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
2649
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
Yes, specify investigation result(s): (select all that apply)
Invest Schedule Ind
Yes
Invest No Control Room Ind
Yes
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Equipment Failure
Cause Details
Pump Or Pump-Related Equipment
Eq Failure Type
Pump Or Pump-Related Equipment
Other Pump Ind
Other
Other Pump Details
Internal Snap Rings.
Eq Additional Other Ind
Yes
Eq Additional Other Details
Failed Snap Rings
Preparer Name
S*** C*******
Preparer Title
Specialist-Technical Compliance Code St Ii
Preparer Email
S************@k***********.com
Preparer Telephone
713-420-4277
Prepared Date
2024-06-03 00:00:00
Local Contact Name
J*** O**
Local Contact Email
J**********@k***********.com
Local Contact Telephone
562-215-5046
Authorizer Name
M*** P****
Authorizer Telephone
770-751-4054
Authorizer Title
Manager Codes And Standards
Authorizer Email
M************@k***********.com
Narrative
On july 9, 2022, at approximately 08:30 cst, kinder morgan crude and condensate (PHMSA opid #23678) local operations personnel received a telephone call from a landowner stating they smelled a petroleum odor near mainline block valve 90 located in wharton county tx, near the town of wharton. Local operations personnel contacted houston control center (hcc) to shut down the pipe. Operations personnel then began to travel to the reported location. Upon arrival at 09:20, crude oil was witnessed spilling from the interface system pump. The failed pump was isolated and the oil spill response plan was initiated. Based on an initial estimate, 69 gallons of crude oil released, the railroad commission of tx was notified telephonically at 09:58. The contracted osro arrived and began remediation activities. The gps coordinates were incorrect and updated on 9.8.22 at 0915. The failed pump was shipped to the manufacturer for failure analysis. The cause of the failure was determined to be failed snap rings. September 2022 update: total volume release updated from 69 gallons to 13 barrels. June 2024 update: submitting final report with administrative changes.
| Report Received Date | 2022-08-08 00:00:00 |
|---|---|
| Iyear | 2022 |
| Report Number | 20220174 |
| Supplemental Number | 39631 |
| Report Type | Supplemental Final |
| Operator Id | 32678 PHMSA Enforcement |
| Name | Kinder Morgan Crude And Condensate Llc |
| Operator Street Address | 1001 Louisiana St., Suite 1000 |
| Operator City Name | Houston |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77002 |
| Local Datetime | 2022-07-09 00:50:00 |
| Time Zone | Central |
| Daylight Savings Ind | Yes |
| Location Latitude | 29.244414 Google Maps OpenStreetMap |
| Location Longitude | -96.1036 Google Maps OpenStreetMap |
| Commodity Released Type | Crude Oil |
| Unintentional Release Bbls | 13 |
| Recovered Bbls | 13 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Notification From Public |
| Incident Identified Datetime | 2022-07-09 09:20:00 |
| System Part Involved | Onshore Pipeline, Including Valve Sites |
| On Off Shore | Onshore |
| Status When Identified | Normal Operation, Includes Pauses Between Batches And During Maintenance |
| Shutdown Due Accident Ind | Yes |
| Shutdown Datetime | 2022-07-09 08:43:00 |
| Restart Datetime | 2022-07-09 14:08:00 |
| Communication State Fed Ind | Yes |
| Party Initiated Communication | Operator |
| Initial Responder Com Datetime | 2022-07-09 09:58:00 |
| On Site Datetime | 2022-07-09 09:20:00 |
| Confirmed Discovery Datetime | 2022-07-09 09:20:00 |
| Nrc Rpt Num | Nrc Notification Not Required NRC Report How to search |
| Ignite Ind | No |
| Upstream Action Taken | Valve Closure |
| Upstream Valve Close Datetime | 2022-07-09 09:35:00 |
| Upstream Valve Type Ind | Manual |
| Downstream Action Taken | Valve Closure |
| Downstream Vlv Close Datetime | 2022-07-09 09:35:00 |
| Downstream Valve Type Ind | Manual |
| Notify Qualified Indiv Ind | Yes |
| Qualified Indiv Notif Datetime | 2022-07-09 08:30:00 |
| Oil Spill Removal Org Ind | Yes |
| Osro Activated Datetime | 2022-07-09 09:30:00 |
| Osro Arrived On Site Dt | 7/9/2022 9:45 |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Dewitt To Oil Tanking |
| Segment Name | 30" Edna To Missouri City |
| Onshore State Abbreviation | Tx |
| Onshore Postal Code | 77488 |
| Onshore City Name | Wharton |
| Onshore County Name | Wharton |
| Designated Location | Milepost |
| Designated Name | 89.59 |
| Federal | No |
| Location Type | Totally Contained On Operator-Controlled Property |
| Incident Area Type | Aboveground |
| Incident Area Subtype | Typical Aboveground Facility Piping Or Appurtenance |
| Crossing | No |
| Pipe Facility Type | Intrastate |
| Item Involved | Pump |
| Pump Type | Positive Displacement |
| Pump Service Type | Injection |
| Installation Year | 2018 |
| Manufactured Year | 2018 |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Seal Or Packing |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | No |
| Remediation Ind | No |
| Water Contam Ind | No |
| Could Be Hca | No |
| Commodity Reached Hca | No |
| Est Cost Oper Paid | 0 |
| Est Cost Gas Released | 1316 |
| Est Cost Prop Damage | 1500 |
| Est Cost Emergency | 13880 |
| Est Cost Environmental | 32500 |
| Est Cost Other | 0 |
| Prpty | 49196 |
| Num Persons Hosp Not Ovnght | 0 |
| Num Injured Treated By Emt | 0 |
| Num Resident Building Affctd | 0 |
| Num Business Building Affctd | 0 |
| Accident Psig | 447 |
| Mop Psig | 780 |
| Mop Cfr Section | Internal Design Pressure �195.406(A)(1) View CFR 49 §192 |
| Maop Established Date | 2012-10-05 00:00:00 |
| Maop Reversal Flow Ind | No |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Length Segment Isolated | 2649 |
| Internal Inspection Ind | Yes |
| Operation Complications Ind | No |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | No |
| Cpm In Place Ind | No |
| Investigation Status | Yes, specify investigation result(s): (select all that apply) |
| Invest Schedule Ind | Yes |
| Invest No Control Room Ind | Yes |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Equipment Failure |
| Cause Details | Pump Or Pump-Related Equipment |
| Eq Failure Type | Pump Or Pump-Related Equipment |
| Other Pump Ind | Other |
| Other Pump Details | Internal Snap Rings. |
| Eq Additional Other Ind | Yes |
| Eq Additional Other Details | Failed Snap Rings |
| Preparer Name | S*** C******* |
| Preparer Title | Specialist-Technical Compliance Code St Ii |
| Preparer Email | S************@k***********.com |
| Preparer Telephone | 713-420-4277 |
| Prepared Date | 2024-06-03 00:00:00 |
| Local Contact Name | J*** O** |
| Local Contact Email | J**********@k***********.com |
| Local Contact Telephone | 562-215-5046 |
| Authorizer Name | M*** P**** |
| Authorizer Telephone | 770-751-4054 |
| Authorizer Title | Manager Codes And Standards |
| Authorizer Email | M************@k***********.com |
| Narrative | On july 9, 2022, at approximately 08:30 cst, kinder morgan crude and condensate (PHMSA opid #23678) local operations personnel received a telephone call from a landowner stating they smelled a petroleum odor near mainline block valve 90 located in wharton county tx, near the town of wharton. Local operations personnel contacted houston control center (hcc) to shut down the pipe. Operations personnel then began to travel to the reported location. Upon arrival at 09:20, crude oil was witnessed spilling from the interface system pump. The failed pump was isolated and the oil spill response plan was initiated. Based on an initial estimate, 69 gallons of crude oil released, the railroad commission of tx was notified telephonically at 09:58. The contracted osro arrived and began remediation activities. The gps coordinates were incorrect and updated on 9.8.22 at 0915. The failed pump was shipped to the manufacturer for failure analysis. The cause of the failure was determined to be failed snap rings. September 2022 update: total volume release updated from 69 gallons to 13 barrels. June 2024 update: submitting final report with administrative changes. |