HL incident on 2022-06-30 — TX
Operator
Energy Transfer Company
Cause
Equipment Failure
Commodity
Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$87,000
Incident datetime
2022-06-30 09:15
Report number
Location
TX
Narrative
On june 30, 2022, at approximately 09:15 there was a release of natural gas liquids (ngl) for the s131 ngl coyanosa to pegasus junction line, a regulated intrastate transmission line located 14.6 miles west of crane, tx in crane county. Crews excavated and were attempting to replace a 4 inch check valve clapper and closed the downstream 4 inch gate valve to block off the check valve. When the crew began removing the check valve top maintenance plate, ngl began to escape from the plate. Crew evacuated the work area. The release of ngl was due to a leaking gate valve downstream of the check valve. A new 4 inch gate valve and 4 inch check valve was installed and on july 2 at approximately 13:00 the pipeline was put back in service. On july 11, 2022 at approximately 09:00, it was determined that the damage and repair estimate was going to go over the $50,000.00 reporting criteria. To prevent this release from occurring in the future, operations boxed in the check valve and installed a 0.5 inch nipple and valve on the check valve maintenance plate to ensure no product is in the line.
Detailed record list
Report Received Date
2022-07-26 00:00:00
Iyear
2022
Report Number
20220160
Supplemental Number
37559
Report Type
Supplemental Final
Operator Id
32099
Name
Energy Transfer Company
Operator Street Address
1300 Main Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2022-07-11 09:00:00
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
31.346504
Location Longitude
-102.590809
Commodity Released Type
Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Commodity Subtype
Lpg (Liquefied Petroleum Gas) / Ngl (Natural Gas Liquid)
Unintentional Release Bbls
5000
Intentional Release Bbls
0
Recovered Bbls
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Contractor Working For The Operator
Incident Identified Datetime
2022-06-30 09:15:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Status When Identified
Post-Maintenance/repair
Communication State Fed Ind
No
On Site Datetime
2022-06-30 09:15:00
Confirmed Discovery Datetime
2022-06-30 09:15:00
Nrc Rpt Datetime
2022-07-11 09:35:00
Nrc Rpt Num
1341177
Additional Nrc Report Numbers
1341354
Ignite Ind
No
Upstream Action Taken
Valve Closure
Upstream Valve Close Datetime
2022-06-30 09:45:00
Upstream Valve Type Ind
Manual
Downstream Action Taken
Valve Closure
Downstream Vlv Close Datetime
2022-06-30 09:50:00
Downstream Valve Type Ind
Manual
Num Pub Evacuated
0
Pipe Fac Name
Tx Ngl Coyanosa To Pegasus Junction
Segment Name
S131
Onshore State Abbreviation
Tx
Onshore Postal Code
79731
Onshore City Name
Crane
Onshore County Name
Crane
Designated Location
Milepost
Designated Name
155+232
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Exposed Due To Excavation
Depth Of Cover
16
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Valve
Valve Type
Mainline
Valve Mainline Type
Gate
Valve Manufacturer
Unknown
Installation Year
1990
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Seal Or Packing
Wildlife Impact Ind
No
Soil Contamination
No
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
231900
Est Cost Prop Damage
87000
Est Cost Emergency
1000
Est Cost Environmental
0
Est Cost Other
0
Prpty
319900
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
900
Mop Psig
1440
Mop Cfr Section
Internal Design Pressure �195.406(A)(1)
Maop Established Date
1988-08-10 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
69970
Internal Inspection Ind
Yes
Operation Complications Ind
Yes
Low Flow Ind
Yes
Pipeline Function
< 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Investigation identified no controller issues. Controller actions were consistent with company protocols.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Equipment Failure
Cause Details
Malfunction Of Control/relief Equipment
Eq Failure Type
Malfunction Of Control/relief Equipment
Block Valve Ind
Yes
Additional Valve Ind
Yes
Preparer Name
C********** P******
Preparer Title
Specialist Regulatory Compliance
Preparer Email
C******************@e*************.com
Preparer Telephone
713 -989-4464
Prepared Date
2023-01-09 00:00:00
Authorizer Name
C**** K*****
Authorizer Telephone
713-989-7077
Authorizer Title
Manager Regulatory Compliance
Authorizer Email
C***********@e*************.com
Narrative
On june 30, 2022, at approximately 09:15 there was a release of natural gas liquids (ngl) for the s131 ngl coyanosa to pegasus junction line, a regulated intrastate transmission line located 14.6 miles west of crane, tx in crane county. Crews excavated and were attempting to replace a 4 inch check valve clapper and closed the downstream 4 inch gate valve to block off the check valve. When the crew began removing the check valve top maintenance plate, ngl began to escape from the plate. Crew evacuated the work area. The release of ngl was due to a leaking gate valve downstream of the check valve. A new 4 inch gate valve and 4 inch check valve was installed and on july 2 at approximately 13:00 the pipeline was put back in service. On july 11, 2022 at approximately 09:00, it was determined that the damage and repair estimate was going to go over the $50,000.00 reporting criteria. To prevent this release from occurring in the future, operations boxed in the check valve and installed a 0.5 inch nipple and valve on the check valve maintenance plate to ensure no product is in the line.
| Report Received Date | 2022-07-26 00:00:00 |
|---|---|
| Iyear | 2022 |
| Report Number | 20220160 |
| Supplemental Number | 37559 |
| Report Type | Supplemental Final |
| Operator Id | 32099 PHMSA Enforcement |
| Name | Energy Transfer Company |
| Operator Street Address | 1300 Main Street |
| Operator City Name | Houston |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77002 |
| Local Datetime | 2022-07-11 09:00:00 |
| Time Zone | Central |
| Daylight Savings Ind | Yes |
| Location Latitude | 31.346504 Google Maps OpenStreetMap |
| Location Longitude | -102.590809 Google Maps OpenStreetMap |
| Commodity Released Type | Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions |
| Commodity Subtype | Lpg (Liquefied Petroleum Gas) / Ngl (Natural Gas Liquid) |
| Unintentional Release Bbls | 5000 |
| Intentional Release Bbls | 0 |
| Recovered Bbls | 0 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Local Operating Personnel, Including Contractors |
| Operator Type | Contractor Working For The Operator |
| Incident Identified Datetime | 2022-06-30 09:15:00 |
| System Part Involved | Onshore Pipeline, Including Valve Sites |
| On Off Shore | Onshore |
| Status When Identified | Post-Maintenance/repair |
| Communication State Fed Ind | No |
| On Site Datetime | 2022-06-30 09:15:00 |
| Confirmed Discovery Datetime | 2022-06-30 09:15:00 |
| Nrc Rpt Datetime | 2022-07-11 09:35:00 |
| Nrc Rpt Num | 1341177 NRC Report How to search |
| Additional Nrc Report Numbers | 1341354 |
| Ignite Ind | No |
| Upstream Action Taken | Valve Closure |
| Upstream Valve Close Datetime | 2022-06-30 09:45:00 |
| Upstream Valve Type Ind | Manual |
| Downstream Action Taken | Valve Closure |
| Downstream Vlv Close Datetime | 2022-06-30 09:50:00 |
| Downstream Valve Type Ind | Manual |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Tx Ngl Coyanosa To Pegasus Junction |
| Segment Name | S131 |
| Onshore State Abbreviation | Tx |
| Onshore Postal Code | 79731 |
| Onshore City Name | Crane |
| Onshore County Name | Crane |
| Designated Location | Milepost |
| Designated Name | 155+232 |
| Federal | No |
| Location Type | Pipeline Right-Of-Way |
| Incident Area Type | Underground |
| Incident Area Subtype | Exposed Due To Excavation |
| Depth Of Cover | 16 |
| Crossing | No |
| Pipe Facility Type | Intrastate |
| Item Involved | Valve |
| Valve Type | Mainline |
| Valve Mainline Type | Gate |
| Valve Manufacturer | Unknown |
| Installation Year | 1990 |
| Manufactured Year | Unknown |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Seal Or Packing |
| Wildlife Impact Ind | No |
| Soil Contamination | No |
| Long Term Assessment | No |
| Remediation Ind | No |
| Water Contam Ind | No |
| Could Be Hca | No |
| Commodity Reached Hca | No |
| Est Cost Oper Paid | 0 |
| Est Cost Gas Released | 231900 |
| Est Cost Prop Damage | 87000 |
| Est Cost Emergency | 1000 |
| Est Cost Environmental | 0 |
| Est Cost Other | 0 |
| Prpty | 319900 |
| Num Persons Hosp Not Ovnght | 0 |
| Num Injured Treated By Emt | 0 |
| Num Resident Building Affctd | 0 |
| Num Business Building Affctd | 0 |
| Accident Psig | 900 |
| Mop Psig | 1440 |
| Mop Cfr Section | Internal Design Pressure �195.406(A)(1) View CFR 49 §192 |
| Maop Established Date | 1988-08-10 00:00:00 |
| Maop Reversal Flow Ind | No |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Length Segment Isolated | 69970 |
| Internal Inspection Ind | Yes |
| Operation Complications Ind | Yes |
| Low Flow Ind | Yes |
| Pipeline Function | < 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | No |
| Cpm In Place Ind | No |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | Investigation identified no controller issues. Controller actions were consistent with company protocols. |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Equipment Failure |
| Cause Details | Malfunction Of Control/relief Equipment |
| Eq Failure Type | Malfunction Of Control/relief Equipment |
| Block Valve Ind | Yes |
| Additional Valve Ind | Yes |
| Preparer Name | C********** P****** |
| Preparer Title | Specialist Regulatory Compliance |
| Preparer Email | C******************@e*************.com |
| Preparer Telephone | 713 -989-4464 |
| Prepared Date | 2023-01-09 00:00:00 |
| Authorizer Name | C**** K***** |
| Authorizer Telephone | 713-989-7077 |
| Authorizer Title | Manager Regulatory Compliance |
| Authorizer Email | C***********@e*************.com |
| Narrative | On june 30, 2022, at approximately 09:15 there was a release of natural gas liquids (ngl) for the s131 ngl coyanosa to pegasus junction line, a regulated intrastate transmission line located 14.6 miles west of crane, tx in crane county. Crews excavated and were attempting to replace a 4 inch check valve clapper and closed the downstream 4 inch gate valve to block off the check valve. When the crew began removing the check valve top maintenance plate, ngl began to escape from the plate. Crew evacuated the work area. The release of ngl was due to a leaking gate valve downstream of the check valve. A new 4 inch gate valve and 4 inch check valve was installed and on july 2 at approximately 13:00 the pipeline was put back in service. On july 11, 2022 at approximately 09:00, it was determined that the damage and repair estimate was going to go over the $50,000.00 reporting criteria. To prevent this release from occurring in the future, operations boxed in the check valve and installed a 0.5 inch nipple and valve on the check valve maintenance plate to ensure no product is in the line. |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company
All rights reserved. Copyright © by ClearPHMSA