HL incident on 2022-06-30 — TX

Operator
Energy Transfer Company
Cause
Equipment Failure
Commodity
Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$87,000
Incident datetime
2022-06-30 09:15
Report number
Location
TX
Narrative
On june 30, 2022, at approximately 09:15 there was a release of natural gas liquids (ngl) for the s131 ngl coyanosa to pegasus junction line, a regulated intrastate transmission line located 14.6 miles west of crane, tx in crane county. Crews excavated and were attempting to replace a 4 inch check valve clapper and closed the downstream 4 inch gate valve to block off the check valve. When the crew began removing the check valve top maintenance plate, ngl began to escape from the plate. Crew evacuated the work area. The release of ngl was due to a leaking gate valve downstream of the check valve. A new 4 inch gate valve and 4 inch check valve was installed and on july 2 at approximately 13:00 the pipeline was put back in service. On july 11, 2022 at approximately 09:00, it was determined that the damage and repair estimate was going to go over the $50,000.00 reporting criteria. To prevent this release from occurring in the future, operations boxed in the check valve and installed a 0.5 inch nipple and valve on the check valve maintenance plate to ensure no product is in the line.
Detailed record list
Report Received Date
2022-07-26 00:00:00
Iyear
2022
Report Number
20220160
Supplemental Number
37559
Report Type
Supplemental Final
Operator Id
Name
Energy Transfer Company
Operator Street Address
1300 Main Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2022-07-11 09:00:00
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
Commodity Released Type
Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Commodity Subtype
Lpg (Liquefied Petroleum Gas) / Ngl (Natural Gas Liquid)
Unintentional Release Bbls
5000
Intentional Release Bbls
0
Recovered Bbls
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Contractor Working For The Operator
Incident Identified Datetime
2022-06-30 09:15:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Status When Identified
Post-Maintenance/repair
Communication State Fed Ind
No
On Site Datetime
2022-06-30 09:15:00
Confirmed Discovery Datetime
2022-06-30 09:15:00
Nrc Rpt Datetime
2022-07-11 09:35:00
Nrc Rpt Num
Additional Nrc Report Numbers
1341354
Ignite Ind
No
Upstream Action Taken
Valve Closure
Upstream Valve Close Datetime
2022-06-30 09:45:00
Upstream Valve Type Ind
Manual
Downstream Action Taken
Valve Closure
Downstream Vlv Close Datetime
2022-06-30 09:50:00
Downstream Valve Type Ind
Manual
Num Pub Evacuated
0
Pipe Fac Name
Tx Ngl Coyanosa To Pegasus Junction
Segment Name
S131
Onshore State Abbreviation
Tx
Onshore Postal Code
79731
Onshore City Name
Crane
Onshore County Name
Crane
Designated Location
Milepost
Designated Name
155+232
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Exposed Due To Excavation
Depth Of Cover
16
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Valve
Valve Type
Mainline
Valve Mainline Type
Gate
Valve Manufacturer
Unknown
Installation Year
1990
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Seal Or Packing
Wildlife Impact Ind
No
Soil Contamination
No
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
231900
Est Cost Prop Damage
87000
Est Cost Emergency
1000
Est Cost Environmental
0
Est Cost Other
0
Prpty
319900
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
900
Mop Psig
1440
Mop Cfr Section
Internal Design Pressure �195.406(A)(1)
Maop Established Date
1988-08-10 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
69970
Internal Inspection Ind
Yes
Operation Complications Ind
Yes
Low Flow Ind
Yes
Pipeline Function
< 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Investigation identified no controller issues. Controller actions were consistent with company protocols.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Equipment Failure
Cause Details
Malfunction Of Control/relief Equipment
Eq Failure Type
Malfunction Of Control/relief Equipment
Block Valve Ind
Yes
Additional Valve Ind
Yes
Preparer Name
C********** P******
Preparer Title
Specialist Regulatory Compliance
Preparer Email
C******************@e*************.com
Preparer Telephone
713 -989-4464
Prepared Date
2023-01-09 00:00:00
Authorizer Name
C**** K*****
Authorizer Telephone
713-989-7077
Authorizer Title
Manager Regulatory Compliance
Authorizer Email
C***********@e*************.com
Narrative
On june 30, 2022, at approximately 09:15 there was a release of natural gas liquids (ngl) for the s131 ngl coyanosa to pegasus junction line, a regulated intrastate transmission line located 14.6 miles west of crane, tx in crane county. Crews excavated and were attempting to replace a 4 inch check valve clapper and closed the downstream 4 inch gate valve to block off the check valve. When the crew began removing the check valve top maintenance plate, ngl began to escape from the plate. Crew evacuated the work area. The release of ngl was due to a leaking gate valve downstream of the check valve. A new 4 inch gate valve and 4 inch check valve was installed and on july 2 at approximately 13:00 the pipeline was put back in service. On july 11, 2022 at approximately 09:00, it was determined that the damage and repair estimate was going to go over the $50,000.00 reporting criteria. To prevent this release from occurring in the future, operations boxed in the check valve and installed a 0.5 inch nipple and valve on the check valve maintenance plate to ensure no product is in the line.
Report Received Date 2022-07-26 00:00:00
Iyear 2022
Report Number 20220160
Supplemental Number 37559
Report Type Supplemental Final
Operator Id 32099 PHMSA Enforcement
Name Energy Transfer Company
Operator Street Address 1300 Main Street
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77002
Local Datetime 2022-07-11 09:00:00
Time Zone Central
Daylight Savings Ind Yes
Location Latitude 31.346504 Google Maps OpenStreetMap
Location Longitude -102.590809 Google Maps OpenStreetMap
Commodity Released Type Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Commodity Subtype Lpg (Liquefied Petroleum Gas) / Ngl (Natural Gas Liquid)
Unintentional Release Bbls 5000
Intentional Release Bbls 0
Recovered Bbls 0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Local Operating Personnel, Including Contractors
Operator Type Contractor Working For The Operator
Incident Identified Datetime 2022-06-30 09:15:00
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Status When Identified Post-Maintenance/repair
Communication State Fed Ind No
On Site Datetime 2022-06-30 09:15:00
Confirmed Discovery Datetime 2022-06-30 09:15:00
Nrc Rpt Datetime 2022-07-11 09:35:00
Nrc Rpt Num 1341177 NRC Report How to search
Additional Nrc Report Numbers 1341354
Ignite Ind No
Upstream Action Taken Valve Closure
Upstream Valve Close Datetime 2022-06-30 09:45:00
Upstream Valve Type Ind Manual
Downstream Action Taken Valve Closure
Downstream Vlv Close Datetime 2022-06-30 09:50:00
Downstream Valve Type Ind Manual
Num Pub Evacuated 0
Pipe Fac Name Tx Ngl Coyanosa To Pegasus Junction
Segment Name S131
Onshore State Abbreviation Tx
Onshore Postal Code 79731
Onshore City Name Crane
Onshore County Name Crane
Designated Location Milepost
Designated Name 155+232
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Exposed Due To Excavation
Depth Of Cover 16
Crossing No
Pipe Facility Type Intrastate
Item Involved Valve
Valve Type Mainline
Valve Mainline Type Gate
Valve Manufacturer Unknown
Installation Year 1990
Manufactured Year Unknown
Material Involved Carbon Steel
Release Type Leak
Leak Type Seal Or Packing
Wildlife Impact Ind No
Soil Contamination No
Long Term Assessment No
Remediation Ind No
Water Contam Ind No
Could Be Hca No
Commodity Reached Hca No
Est Cost Oper Paid 0
Est Cost Gas Released 231900
Est Cost Prop Damage 87000
Est Cost Emergency 1000
Est Cost Environmental 0
Est Cost Other 0
Prpty 319900
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Accident Psig 900
Mop Psig 1440
Mop Cfr Section Internal Design Pressure �195.406(A)(1) View CFR 49 §192
Maop Established Date 1988-08-10 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Length Segment Isolated 69970
Internal Inspection Ind Yes
Operation Complications Ind Yes
Low Flow Ind Yes
Pipeline Function < 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Cpm In Place Ind No
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details Investigation identified no controller issues. Controller actions were consistent with company protocols.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Equipment Failure
Cause Details Malfunction Of Control/relief Equipment
Eq Failure Type Malfunction Of Control/relief Equipment
Block Valve Ind Yes
Additional Valve Ind Yes
Preparer Name C********** P******
Preparer Title Specialist Regulatory Compliance
Preparer Email C******************@e*************.com
Preparer Telephone 713 -989-4464
Prepared Date 2023-01-09 00:00:00
Authorizer Name C**** K*****
Authorizer Telephone 713-989-7077
Authorizer Title Manager Regulatory Compliance
Authorizer Email C***********@e*************.com
Narrative On june 30, 2022, at approximately 09:15 there was a release of natural gas liquids (ngl) for the s131 ngl coyanosa to pegasus junction line, a regulated intrastate transmission line located 14.6 miles west of crane, tx in crane county. Crews excavated and were attempting to replace a 4 inch check valve clapper and closed the downstream 4 inch gate valve to block off the check valve. When the crew began removing the check valve top maintenance plate, ngl began to escape from the plate. Crew evacuated the work area. The release of ngl was due to a leaking gate valve downstream of the check valve. A new 4 inch gate valve and 4 inch check valve was installed and on july 2 at approximately 13:00 the pipeline was put back in service. On july 11, 2022 at approximately 09:00, it was determined that the damage and repair estimate was going to go over the $50,000.00 reporting criteria. To prevent this release from occurring in the future, operations boxed in the check valve and installed a 0.5 inch nipple and valve on the check valve maintenance plate to ensure no product is in the line.

All rights reserved. Copyright © by ClearPHMSA