Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2022-06-22 — TX
Operator
Kinder Morgan Crude And Condensate Llc
Cause
Incorrect Operation
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$488,470
Incident datetime
2022-06-22 12:15
Report number
Location
TX
Narrative
06/22/2022- an aerial patrol pilot notified kinder morgan crude and condensate operations personnel of a stain on the row on the intrastate 30 inch kmcc dewitt to oti line near the city of edna in jackson county, texas at approximately 11:30 cst. Operations dispatched personnel to the site and they confirmed a crude oil release at 12:15pm cst. The pipeline was already on a scheduled shutdown at the time of the reported staining. Based on initial estimate of a crude oil release greater than 5 gallons, a telephonic notification was made to the railroad commission of texas's emergency line. Additional calls to 911, kinder morgan contract osro's were also made and the kmcc emergency response plan was implemented. When local operations anticipated cost of repair to exceed $50k, a call was made to the national response center at 2130 on 6/22/2022 (nrc#1339540). The source of the release was identified as a crack on the pipeline. The failed section of pipe was cut out and replaced. The failed section was sent off for a metallurgical analysis to determine the root cause failure. The root cause and updated property damage costs will be provided in a future supplemental and final 7000.1 report. Update 09/2/2022 metallurgical analysis concluded the crack started at a location where the welder stopped and restarted during initial construction in 1952. The crack expanded from that spot over time due to cyclical stresses. . It is assumed that in 1952 no x-ray took place that potentially could have identified a crack that resulted in a failure 70 years after construction was completed. (g6 - incorrect operation; equipment not installed properly)(contributing factor - inadequate procedure)
Detailed record list
Report Received Date
2022-07-22 00:00:00
Iyear
2022
Report Number
20220157
Supplemental Number
37069
Report Type
Supplemental Final
Operator Id
32678
Name
Kinder Morgan Crude And Condensate Llc
Operator Street Address
1001 Louisiana St., Suite 1000
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2022-06-22 11:30:00
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
28.93896
Location Longitude
-96.584013
Commodity Released Type
Crude Oil
Unintentional Release Bbls
13.92
Recovered Bbls
11.9
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Air Patrol
Operator Type
Contractor Working For The Operator
Incident Identified Datetime
2022-06-22 12:15:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Status When Identified
Routine Shutdown
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Initial Responder Com Datetime
2022-06-22 13:00:00
On Site Datetime
2022-06-22 12:15:00
Confirmed Discovery Datetime
2022-06-22 12:15:00
Nrc Rpt Datetime
2022-06-22 21:30:00
Nrc Rpt Num
1339540
Additional Nrc Report Numbers
1339696
Ignite Ind
No
Upstream Action Taken
Valve Closure
Upstream Valve Close Datetime
2022-06-22 11:37:00
Upstream Valve Type Ind
Remotely Controlled
Downstream Action Taken
Valve Closure
Downstream Vlv Close Datetime
2022-06-22 11:40:00
Downstream Valve Type Ind
Remotely Controlled
Notify Qualified Indiv Ind
Yes
Qualified Indiv Notif Datetime
2022-06-22 11:30:00
Oil Spill Removal Org Ind
Yes
Osro Activated Datetime
2022-06-22 12:30:00
Osro Arrived On Site Dt
6/22/2022 13:30
Num Pub Evacuated
0
Pipe Fac Name
Dewitt To Oil Tanking
Segment Name
30" Edna To Missouri City
Onshore State Abbreviation
Tx
Onshore Postal Code
77957
Onshore City Name
Edna
Onshore County Name
Jackson
Designated Location
Milepost
Designated Name
53.47
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
36
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Pipe
Pipe Type
Pipe Seam
Pipe Diameter
30
Pipe Wall Thickness
0.344
Pipe Smys
52000
Pipe Specification
X52
Pipe Seam Type
Dsaw
Pipe Manufacturer
Unknown
Pipe Coating Type
Coal Tar
Coating Applied Ind
Unknown
Installation Year
1952
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Crack
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
10000
Est Cost Gas Released
1482
Est Cost Prop Damage
488470
Est Cost Emergency
96135
Est Cost Environmental
225807
Est Cost Other
0
Prpty
821894
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
119
Mop Psig
858
Mop Cfr Section
Internal Design Pressure �195.406(A)(1)
Maop Established Date
2019-02-23 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
247616
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
Yes
Cpm In Place Ind
No
Investigation Status
Yes, specify investigation result(s): (select all that apply)
Invest Schedule Ind
Yes
Invest No Control Room Ind
Yes
Invest No Controller Ind
Yes
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Incorrect Operation
Cause Details
Equipment Not Installed Properly
Operation Type
Equipment Not Installed Properly
Related Inadequate Proc Ind
Yes
Category Type
Construction
Operator Qualification Ind
No
Preparer Name
J**** P*******
Preparer Title
Specialist - Technical Compliance Code St Sr Ii
Preparer Email
J*************@k***********.com
Preparer Telephone
7134207004
Prepared Date
2022-09-02 00:00:00
Local Contact Name
J****** O**
Local Contact Email
J**********@k***********.com
Local Contact Telephone
9795318137
Authorizer Name
D******* S*******
Authorizer Telephone
7134206496
Authorizer Title
Manager - Compliance Code St
Authorizer Email
D****************@k***********.com
Narrative
06/22/2022- an aerial patrol pilot notified kinder morgan crude and condensate operations personnel of a stain on the row on the intrastate 30 inch kmcc dewitt to oti line near the city of edna in jackson county, texas at approximately 11:30 cst. Operations dispatched personnel to the site and they confirmed a crude oil release at 12:15pm cst. The pipeline was already on a scheduled shutdown at the time of the reported staining. Based on initial estimate of a crude oil release greater than 5 gallons, a telephonic notification was made to the railroad commission of texas's emergency line. Additional calls to 911, kinder morgan contract osro's were also made and the kmcc emergency response plan was implemented. When local operations anticipated cost of repair to exceed $50k, a call was made to the national response center at 2130 on 6/22/2022 (nrc#1339540). The source of the release was identified as a crack on the pipeline. The failed section of pipe was cut out and replaced. The failed section was sent off for a metallurgical analysis to determine the root cause failure. The root cause and updated property damage costs will be provided in a future supplemental and final 7000.1 report. Update 09/2/2022 metallurgical analysis concluded the crack started at a location where the welder stopped and restarted during initial construction in 1952. The crack expanded from that spot over time due to cyclical stresses. . It is assumed that in 1952 no x-ray took place that potentially could have identified a crack that resulted in a failure 70 years after construction was completed. (g6 - incorrect operation; equipment not installed properly)(contributing factor - inadequate procedure)
| Report Received Date | 2022-07-22 00:00:00 |
|---|---|
| Iyear | 2022 |
| Report Number | 20220157 |
| Supplemental Number | 37069 |
| Report Type | Supplemental Final |
| Operator Id | 32678 PHMSA Enforcement |
| Name | Kinder Morgan Crude And Condensate Llc |
| Operator Street Address | 1001 Louisiana St., Suite 1000 |
| Operator City Name | Houston |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77002 |
| Local Datetime | 2022-06-22 11:30:00 |
| Time Zone | Central |
| Daylight Savings Ind | Yes |
| Location Latitude | 28.93896 Google Maps OpenStreetMap |
| Location Longitude | -96.584013 Google Maps OpenStreetMap |
| Commodity Released Type | Crude Oil |
| Unintentional Release Bbls | 13.92 |
| Recovered Bbls | 11.9 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Air Patrol |
| Operator Type | Contractor Working For The Operator |
| Incident Identified Datetime | 2022-06-22 12:15:00 |
| System Part Involved | Onshore Pipeline, Including Valve Sites |
| On Off Shore | Onshore |
| Status When Identified | Routine Shutdown |
| Communication State Fed Ind | Yes |
| Party Initiated Communication | Operator |
| Initial Responder Com Datetime | 2022-06-22 13:00:00 |
| On Site Datetime | 2022-06-22 12:15:00 |
| Confirmed Discovery Datetime | 2022-06-22 12:15:00 |
| Nrc Rpt Datetime | 2022-06-22 21:30:00 |
| Nrc Rpt Num | 1339540 NRC Report How to search |
| Additional Nrc Report Numbers | 1339696 |
| Ignite Ind | No |
| Upstream Action Taken | Valve Closure |
| Upstream Valve Close Datetime | 2022-06-22 11:37:00 |
| Upstream Valve Type Ind | Remotely Controlled |
| Downstream Action Taken | Valve Closure |
| Downstream Vlv Close Datetime | 2022-06-22 11:40:00 |
| Downstream Valve Type Ind | Remotely Controlled |
| Notify Qualified Indiv Ind | Yes |
| Qualified Indiv Notif Datetime | 2022-06-22 11:30:00 |
| Oil Spill Removal Org Ind | Yes |
| Osro Activated Datetime | 2022-06-22 12:30:00 |
| Osro Arrived On Site Dt | 6/22/2022 13:30 |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Dewitt To Oil Tanking |
| Segment Name | 30" Edna To Missouri City |
| Onshore State Abbreviation | Tx |
| Onshore Postal Code | 77957 |
| Onshore City Name | Edna |
| Onshore County Name | Jackson |
| Designated Location | Milepost |
| Designated Name | 53.47 |
| Federal | No |
| Location Type | Pipeline Right-Of-Way |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Soil |
| Depth Of Cover | 36 |
| Crossing | No |
| Pipe Facility Type | Intrastate |
| Item Involved | Pipe |
| Pipe Type | Pipe Seam |
| Pipe Diameter | 30 |
| Pipe Wall Thickness | 0.344 |
| Pipe Smys | 52000 |
| Pipe Specification | X52 |
| Pipe Seam Type | Dsaw |
| Pipe Manufacturer | Unknown |
| Pipe Coating Type | Coal Tar |
| Coating Applied Ind | Unknown |
| Installation Year | 1952 |
| Manufactured Year | Unknown |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Crack |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | No |
| Remediation Ind | Yes |
| Soil Remed Ind | Yes |
| Water Contam Ind | No |
| Could Be Hca | No |
| Commodity Reached Hca | No |
| Est Cost Oper Paid | 10000 |
| Est Cost Gas Released | 1482 |
| Est Cost Prop Damage | 488470 |
| Est Cost Emergency | 96135 |
| Est Cost Environmental | 225807 |
| Est Cost Other | 0 |
| Prpty | 821894 |
| Num Persons Hosp Not Ovnght | 0 |
| Num Injured Treated By Emt | 0 |
| Num Resident Building Affctd | 0 |
| Num Business Building Affctd | 0 |
| Accident Psig | 119 |
| Mop Psig | 858 |
| Mop Cfr Section | Internal Design Pressure �195.406(A)(1) View CFR 49 §192 |
| Maop Established Date | 2019-02-23 00:00:00 |
| Maop Reversal Flow Ind | No |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Length Segment Isolated | 247616 |
| Internal Inspection Ind | Yes |
| Operation Complications Ind | No |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | Yes |
| Cpm In Place Ind | No |
| Investigation Status | Yes, specify investigation result(s): (select all that apply) |
| Invest Schedule Ind | Yes |
| Invest No Control Room Ind | Yes |
| Invest No Controller Ind | Yes |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Incorrect Operation |
| Cause Details | Equipment Not Installed Properly |
| Operation Type | Equipment Not Installed Properly |
| Related Inadequate Proc Ind | Yes |
| Category Type | Construction |
| Operator Qualification Ind | No |
| Preparer Name | J**** P******* |
| Preparer Title | Specialist - Technical Compliance Code St Sr Ii |
| Preparer Email | J*************@k***********.com |
| Preparer Telephone | 7134207004 |
| Prepared Date | 2022-09-02 00:00:00 |
| Local Contact Name | J****** O** |
| Local Contact Email | J**********@k***********.com |
| Local Contact Telephone | 9795318137 |
| Authorizer Name | D******* S******* |
| Authorizer Telephone | 7134206496 |
| Authorizer Title | Manager - Compliance Code St |
| Authorizer Email | D****************@k***********.com |
| Narrative | 06/22/2022- an aerial patrol pilot notified kinder morgan crude and condensate operations personnel of a stain on the row on the intrastate 30 inch kmcc dewitt to oti line near the city of edna in jackson county, texas at approximately 11:30 cst. Operations dispatched personnel to the site and they confirmed a crude oil release at 12:15pm cst. The pipeline was already on a scheduled shutdown at the time of the reported staining. Based on initial estimate of a crude oil release greater than 5 gallons, a telephonic notification was made to the railroad commission of texas's emergency line. Additional calls to 911, kinder morgan contract osro's were also made and the kmcc emergency response plan was implemented. When local operations anticipated cost of repair to exceed $50k, a call was made to the national response center at 2130 on 6/22/2022 (nrc#1339540). The source of the release was identified as a crack on the pipeline. The failed section of pipe was cut out and replaced. The failed section was sent off for a metallurgical analysis to determine the root cause failure. The root cause and updated property damage costs will be provided in a future supplemental and final 7000.1 report. Update 09/2/2022 metallurgical analysis concluded the crack started at a location where the welder stopped and restarted during initial construction in 1952. The crack expanded from that spot over time due to cyclical stresses. . It is assumed that in 1952 no x-ray took place that potentially could have identified a crack that resulted in a failure 70 years after construction was completed. (g6 - incorrect operation; equipment not installed properly)(contributing factor - inadequate procedure) |
External Resources
PHMSA pipeline safety insights.
Product