GTG incident on 2022-10-31 — TX

Operator
Northwest Pipeline Llc
Cause
Miscellaneous Root Causes
Commodity
Natural Gas
Program
GTG
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$385,000
Incident datetime
2022-10-31 16:24
Report number
Location
TX
Narrative
On october 31, 2022 williams security operation center was notified by nearby authorities that a farmer had struck out 22" mainline with farming equipment while he was deep plowing his field for the winter. Immediately after receiving notification of the incident, pipeline operations responded and went to the site of the incident as quickly as possible. Once on site, operations noticed that the line had been struck hard enough to create a small puncture in the line, venting highly pressurized gas to the atmosphere. Operations quickly moved to manually close the upstream and downstream mainline valves to isolate this section of mainline from pressurized gas. Once this section of mainline was isolated, construction crews and operations worked together to cut out the piece of damaged pipe and install a new spool of pre-tested pipe. Over the course of the next four days this effort was completed and williams was able to restore this section of the mainline back to service. During the outage, the 1401 line, which runs parallel to the damaged 1400 line, was able to operate under normal conditions to avoid any significant disruptions to our customers.
Detailed record list
Report Received Date
2022-11-29 00:00:00
Iyear
2022
Report Number
20220124
Supplemental Number
37425
Report Type
Supplemental Final
Operator Id
Name
Northwest Pipeline Llc
Operator Street Address
2800 Post Oak Blvd
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77056
Local Datetime
2022-10-31 16:00:00
Time Zone
Mountain
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
Nrc Rpt Num
Nrc Rpt Datetime
2022-10-31 17:08:00
Additional Nrc Report Numbers
1351525
Commodity Released Type
Natural Gas
Unintentional Release
359
Intentional Release
9019
Accompanying Liquid
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Status When Identified
Normal Operation, Includes Pauses During Maintenance
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2022-10-31 17:09:00
Restart Datetime
2022-11-04 10:54:00
Ignite Ind
No
Upstream Action Taken
Valve Closure
Upstream Valve Close Datetime
2022-10-31 17:09:00
Downstream Action Taken
Valve Closure
Downstream Vlv Close Datetime
2022-10-31 17:06:00
Num Pub Evacuated
0
Incident Identified Datetime
2022-10-31 16:24:00
On Site Datetime
2022-10-31 16:24:00
On Off Shore
Onshore
Onshore State Abbreviation
Id
Onshore Postal Code
83211
Onshore City Name
American Falls
Onshore County Name
Power County
Pipe Fac Name
Northwest Pipeline
Segment Name
22" 1400 Mainline Mp 619.1
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
19
Other Underground Facilities
No
Crossing
No
Pipe Facility Type
Interstate
System Part Involved
Onshore Pipeline, Including Valve Sites
Item Involved
Pipe
Pipe Type
Pipe Body
Pipe Diameter
22
Puddle Weld Ind
No
Pipe Wall Thickness
0.25
Pipe Smys
52000
Pipe Specification
Api 5lx
Pipe Seam Type
Dsaw
Pipe Manufacturer
Consolidated
Pipe Coating Type
Asphalt
Coating Applied Ind
Yes
Installation Year
1955
Manufactured Year
1955
Material Involved
Carbon Steel
Release Type
Mechanical Puncture
Puncture Axial
0.2
Puncture Circum
0.2
Class Location Type
Class 1 Location
Could Be Hca
No
Pir Radius
442
Heat Damage Ind
No
Non Heat Damage Ind
No
Did Occur In Mca Ind
No
Est Cost Oper Paid
0
Est Cost Unintentional Release
3224
Est Cost Intentional Release
80991
Est Cost Prop Damage
385000
Est Cost Emergency
1500
Est Cost Other
0
Gas Cost In Mcf
8.98
Prpty
470715
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Wildlife Impact Ind
No
Accident Psig
723
Gas Flow In Pipe In Mcf
250000
Mop Psig
850
Mop Cfr Section
192.619(A)(2)
Maop Established Date
1955-12-01 00:00:00
Maop Reversal Flow Ind
Bi-Directional
Accident Pressure
Pressure Did Not Exceed Maop
Pressure Restriction Ind
No
Gas Required Odorized Ind
No
Upstream Valve Type Ind
Manual
Downstream Valve Type Ind
Manual
Length Segment Isolated
63148
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
Transmission System
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
Yes
Scada Conf Ind
No
Accident Identifier
Notification From Emergency Responder
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
The incident was caused by an external force (farmer deep-plowing his field) and the company didn't feel a control room investigation to be necessary as a result of this incident.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Excavation Damage
Cause Details
Excavation Damage By Third Party
Ex Party Type
Excavation Damage By Third Party
Prior Notification Ind
No
State Law Exempt Ind
No
Notify Cga Dirt
No
Private Row Ind
Yes
Private Subtype
Private Landowner
Excavator Type
Farmer
Excavator Equipment
Farm Equipment
Work Performed
Grading
One Call Notified Ind
No
Service Interruption
No
Root Cause Category
Miscellaneous Root Causes
Root Cause Type
Root Cause Not Listed (Comment Required)
Root Cause Type Other
Farmer No 1 Call And Used Line Markers To Call In Strike
Preparer Name
T***** K J*****
Preparer Title
Pipeline Safety Engineer
Preparer Email
T************@w*******.com
Preparer Telephone
2813828869
Authorizer Name
J*** B***
Authorizer Title
Pipeline Safety Manager
Authorizer Telephone
3373179145
Authorizer Email
J********@w*******.com
Narrative
On october 31, 2022 williams security operation center was notified by nearby authorities that a farmer had struck out 22" mainline with farming equipment while he was deep plowing his field for the winter. Immediately after receiving notification of the incident, pipeline operations responded and went to the site of the incident as quickly as possible. Once on site, operations noticed that the line had been struck hard enough to create a small puncture in the line, venting highly pressurized gas to the atmosphere. Operations quickly moved to manually close the upstream and downstream mainline valves to isolate this section of mainline from pressurized gas. Once this section of mainline was isolated, construction crews and operations worked together to cut out the piece of damaged pipe and install a new spool of pre-tested pipe. Over the course of the next four days this effort was completed and williams was able to restore this section of the mainline back to service. During the outage, the 1401 line, which runs parallel to the damaged 1400 line, was able to operate under normal conditions to avoid any significant disruptions to our customers.
Report Received Date 2022-11-29 00:00:00
Iyear 2022
Report Number 20220124
Supplemental Number 37425
Report Type Supplemental Final
Operator Id 13845 PHMSA Enforcement
Name Northwest Pipeline Llc
Operator Street Address 2800 Post Oak Blvd
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77056
Local Datetime 2022-10-31 16:00:00
Time Zone Mountain
Daylight Savings Ind Yes
Location Latitude 42.724314 Google Maps OpenStreetMap
Location Longitude -112.890581 Google Maps OpenStreetMap
Nrc Rpt Num 1351359 NRC Report How to search
Nrc Rpt Datetime 2022-10-31 17:08:00
Additional Nrc Report Numbers 1351525
Commodity Released Type Natural Gas
Unintentional Release 359
Intentional Release 9019
Accompanying Liquid 0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Status When Identified Normal Operation, Includes Pauses During Maintenance
Shutdown Due Accident Ind Yes
Shutdown Datetime 2022-10-31 17:09:00
Restart Datetime 2022-11-04 10:54:00
Ignite Ind No
Upstream Action Taken Valve Closure
Upstream Valve Close Datetime 2022-10-31 17:09:00
Downstream Action Taken Valve Closure
Downstream Vlv Close Datetime 2022-10-31 17:06:00
Num Pub Evacuated 0
Incident Identified Datetime 2022-10-31 16:24:00
On Site Datetime 2022-10-31 16:24:00
On Off Shore Onshore
Onshore State Abbreviation Id
Onshore Postal Code 83211
Onshore City Name American Falls
Onshore County Name Power County
Pipe Fac Name Northwest Pipeline
Segment Name 22" 1400 Mainline Mp 619.1
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 19
Other Underground Facilities No
Crossing No
Pipe Facility Type Interstate
System Part Involved Onshore Pipeline, Including Valve Sites
Item Involved Pipe
Pipe Type Pipe Body
Pipe Diameter 22
Puddle Weld Ind No
Pipe Wall Thickness 0.25
Pipe Smys 52000
Pipe Specification Api 5lx
Pipe Seam Type Dsaw
Pipe Manufacturer Consolidated
Pipe Coating Type Asphalt
Coating Applied Ind Yes
Installation Year 1955
Manufactured Year 1955
Material Involved Carbon Steel
Release Type Mechanical Puncture
Puncture Axial 0.2
Puncture Circum 0.2
Class Location Type Class 1 Location
Could Be Hca No
Pir Radius 442
Heat Damage Ind No
Non Heat Damage Ind No
Did Occur In Mca Ind No
Est Cost Oper Paid 0
Est Cost Unintentional Release 3224
Est Cost Intentional Release 80991
Est Cost Prop Damage 385000
Est Cost Emergency 1500
Est Cost Other 0
Gas Cost In Mcf 8.98
Prpty 470715
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Wildlife Impact Ind No
Accident Psig 723
Gas Flow In Pipe In Mcf 250000
Mop Psig 850
Mop Cfr Section 192.619(A)(2) View CFR 49 §192
Maop Established Date 1955-12-01 00:00:00
Maop Reversal Flow Ind Bi-Directional
Accident Pressure Pressure Did Not Exceed Maop
Pressure Restriction Ind No
Gas Required Odorized Ind No
Upstream Valve Type Ind Manual
Downstream Valve Type Ind Manual
Length Segment Isolated 63148
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function Transmission System
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind Yes
Scada Conf Ind No
Accident Identifier Notification From Emergency Responder
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details The incident was caused by an external force (farmer deep-plowing his field) and the company didn't feel a control room investigation to be necessary as a result of this incident.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Excavation Damage
Cause Details Excavation Damage By Third Party
Ex Party Type Excavation Damage By Third Party
Prior Notification Ind No
State Law Exempt Ind No
Notify Cga Dirt No
Private Row Ind Yes
Private Subtype Private Landowner
Excavator Type Farmer
Excavator Equipment Farm Equipment
Work Performed Grading
One Call Notified Ind No
Service Interruption No
Root Cause Category Miscellaneous Root Causes
Root Cause Type Root Cause Not Listed (Comment Required)
Root Cause Type Other Farmer No 1 Call And Used Line Markers To Call In Strike
Preparer Name T***** K J*****
Preparer Title Pipeline Safety Engineer
Preparer Email T************@w*******.com
Preparer Telephone 2813828869
Authorizer Name J*** B***
Authorizer Title Pipeline Safety Manager
Authorizer Telephone 3373179145
Authorizer Email J********@w*******.com
Narrative On october 31, 2022 williams security operation center was notified by nearby authorities that a farmer had struck out 22" mainline with farming equipment while he was deep plowing his field for the winter. Immediately after receiving notification of the incident, pipeline operations responded and went to the site of the incident as quickly as possible. Once on site, operations noticed that the line had been struck hard enough to create a small puncture in the line, venting highly pressurized gas to the atmosphere. Operations quickly moved to manually close the upstream and downstream mainline valves to isolate this section of mainline from pressurized gas. Once this section of mainline was isolated, construction crews and operations worked together to cut out the piece of damaged pipe and install a new spool of pre-tested pipe. Over the course of the next four days this effort was completed and williams was able to restore this section of the mainline back to service. During the outage, the 1401 line, which runs parallel to the damaged 1400 line, was able to operate under normal conditions to avoid any significant disruptions to our customers.

All rights reserved. Copyright © by ClearPHMSA