Incident details
Operator, cause, commodity and consequences with raw source fields.
GTG incident on 2022-10-03 — TX
Operator
Panhandle Eastern Pipeline Co
Cause
Corrosion Failure
Commodity
Natural Gas
Program
GTG
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$736,962
Incident datetime
2022-10-03 00:21
Report number
Location
TX
Narrative
On 10/03/22 at 00:18, the 24-inch st peter drip line in the waverly storage field failed resulting in a fire. The pipe appears to have failed at the 6 o'clock position on the south end of the pipe. Approximately 7.1 mmcf of natural gas was released. The pipeline was isolated and blowdown by area operations resulting in the fire being extinguished. Local emergency management closed roads and evacuated two residents near the failure site to prevent traffic from entering the area. The failed section of pipe was removed and the line was restarted on 10/06/22 at 11:00. The failed section of pipe was sent to third party laboratory for analysis. The results of the analysis indicated that the rupture occurred by ductile overload at the approximate 6:15 orientation in an area of significant wall thinning from internal corrosion. The internal corrosion that preceded the rupture was likely due to the presence of corrosive gases in the pipeline. To prevent recurrence, a new drip design was prepared to bring the drip above ground so it can be monitored more closely.
Detailed record list
Report Received Date
2022-11-03 00:00:00
Iyear
2022
Report Number
20220115
Supplemental Number
38227
Report Type
Supplemental Final
Operator Id
15105
Name
Panhandle Eastern Pipeline Co
Operator Street Address
1300 Main Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2022-10-03 00:18:00
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
39.572498
Location Longitude
-89.979352
Nrc Rpt Num
1348876
Nrc Rpt Datetime
2022-10-03 02:04:00
Additional Nrc Report Numbers
1349019
Commodity Released Type
Natural Gas
Unintentional Release
7100
Intentional Release
0
Accompanying Liquid
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Status When Identified
Normal Operation, Includes Pauses During Maintenance
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2022-10-03 00:30:00
Restart Datetime
2022-10-06 11:00:00
Ignite Ind
Yes
Ignite Datetime
2022-10-03 00:18:00
How Extinguished
Allowed To Burn Out
Gas Consumed By Fire In Mcf
7100
Explode Ind
No
Num Pub Evacuated
2
Incident Identified Datetime
2022-10-03 00:21:00
On Site Datetime
2022-10-03 00:30:00
On Off Shore
Onshore
Onshore State Abbreviation
Il
Onshore Postal Code
62692
Onshore City Name
Waverly
Onshore County Name
Morgan
Designated Location
Survey Station No.
Designated Name
0+47
Pipe Fac Name
Waverly Storage Field
Segment Name
St Peter Drip 24-Inch
Federal
No
Location Type
Operator-Controlled Property
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
168
Other Underground Facilities
No
Crossing
No
Pipe Facility Type
Interstate
System Part Involved
Aboveground Storage, Including Associated Equipment And Piping
Item Involved
Pulsation Bottle Or Drip/drip Collection Device
Installation Year
2005
Manufactured Year
2005
Material Involved
Carbon Steel
Release Type
Rupture
Rupture Orient
Longitudinal
Rupture Length
72
Rupture Width
48
Class Location Type
Class 1 Location
Could Be Hca
No
Pir Radius
481
Heat Damage Ind
No
Non Heat Damage Ind
No
Did Occur In Mca Ind
No
Est Cost Oper Paid
0
Est Cost Unintentional Release
31453
Est Cost Intentional Release
0
Est Cost Prop Damage
736962
Est Cost Emergency
0
Est Cost Other
1427
Est Cost Other Details
Repayment To Farmer/rancher Who Leased Land For Cattle.
Gas Cost In Mcf
4.43
Prpty
769842
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Wildlife Impact Ind
No
Accident Psig
843
Gas Flow In Pipe In Mcf
28900
Mop Psig
845
Mop Cfr Section
192.619(A)(2)
Maop Established Date
2005-06-01 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Maop
Pressure Restriction Ind
No
Gas Required Odorized Ind
No
Pipeline Function
Transmission In Storage Field
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
Yes
Scada Conf Ind
Yes
Accident Identifier
Notification From Emergency Responder
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Controller actions did not affect the incident.
Employee Drug Test Ind
Yes
Contractor Drug Test Ind
No
Num Employees Tested
4
Num Employees Failed
0
Cause
Corrosion Failure
Cause Details
Internal Corrosion
Internal External
Internal Corrosion
Int Visual Exam Results
Other
Int Visual Exam Details
Pipe Wall Thinning Due To Internal Corrosion. Determined By Metallurgical Analysis.
Int Corrosive Commodity Ind
Yes
Int Metallurgical Basis Ind
Yes
Int Low Point Pipe Loc Ind
Yes
Corrosion Inhibitors
Yes
Corrosion Lining
No
Cleaning Dewatering
No
Corrosion Coupons
Yes
Preparer Name
T*** N*******
Preparer Title
Director - Regulatory Compliance
Preparer Email
T************@e*************.com
Preparer Telephone
713-989-7126
Authorizer Name
T*** N*******
Authorizer Title
Director - Regulatory Compliance
Authorizer Telephone
713-989-7126
Authorizer Email
T************@e*************.com
Narrative
On 10/03/22 at 00:18, the 24-inch st peter drip line in the waverly storage field failed resulting in a fire. The pipe appears to have failed at the 6 o'clock position on the south end of the pipe. Approximately 7.1 mmcf of natural gas was released. The pipeline was isolated and blowdown by area operations resulting in the fire being extinguished. Local emergency management closed roads and evacuated two residents near the failure site to prevent traffic from entering the area. The failed section of pipe was removed and the line was restarted on 10/06/22 at 11:00. The failed section of pipe was sent to third party laboratory for analysis. The results of the analysis indicated that the rupture occurred by ductile overload at the approximate 6:15 orientation in an area of significant wall thinning from internal corrosion. The internal corrosion that preceded the rupture was likely due to the presence of corrosive gases in the pipeline. To prevent recurrence, a new drip design was prepared to bring the drip above ground so it can be monitored more closely.
| Report Received Date | 2022-11-03 00:00:00 |
|---|---|
| Iyear | 2022 |
| Report Number | 20220115 |
| Supplemental Number | 38227 |
| Report Type | Supplemental Final |
| Operator Id | 15105 PHMSA Enforcement |
| Name | Panhandle Eastern Pipeline Co |
| Operator Street Address | 1300 Main Street |
| Operator City Name | Houston |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77002 |
| Local Datetime | 2022-10-03 00:18:00 |
| Time Zone | Central |
| Daylight Savings Ind | Yes |
| Location Latitude | 39.572498 Google Maps OpenStreetMap |
| Location Longitude | -89.979352 Google Maps OpenStreetMap |
| Nrc Rpt Num | 1348876 NRC Report How to search |
| Nrc Rpt Datetime | 2022-10-03 02:04:00 |
| Additional Nrc Report Numbers | 1349019 |
| Commodity Released Type | Natural Gas |
| Unintentional Release | 7100 |
| Intentional Release | 0 |
| Accompanying Liquid | 0 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Status When Identified | Normal Operation, Includes Pauses During Maintenance |
| Shutdown Due Accident Ind | Yes |
| Shutdown Datetime | 2022-10-03 00:30:00 |
| Restart Datetime | 2022-10-06 11:00:00 |
| Ignite Ind | Yes |
| Ignite Datetime | 2022-10-03 00:18:00 |
| How Extinguished | Allowed To Burn Out |
| Gas Consumed By Fire In Mcf | 7100 |
| Explode Ind | No |
| Num Pub Evacuated | 2 |
| Incident Identified Datetime | 2022-10-03 00:21:00 |
| On Site Datetime | 2022-10-03 00:30:00 |
| On Off Shore | Onshore |
| Onshore State Abbreviation | Il |
| Onshore Postal Code | 62692 |
| Onshore City Name | Waverly |
| Onshore County Name | Morgan |
| Designated Location | Survey Station No. |
| Designated Name | 0+47 |
| Pipe Fac Name | Waverly Storage Field |
| Segment Name | St Peter Drip 24-Inch |
| Federal | No |
| Location Type | Operator-Controlled Property |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Soil |
| Depth Of Cover | 168 |
| Other Underground Facilities | No |
| Crossing | No |
| Pipe Facility Type | Interstate |
| System Part Involved | Aboveground Storage, Including Associated Equipment And Piping |
| Item Involved | Pulsation Bottle Or Drip/drip Collection Device |
| Installation Year | 2005 |
| Manufactured Year | 2005 |
| Material Involved | Carbon Steel |
| Release Type | Rupture |
| Rupture Orient | Longitudinal |
| Rupture Length | 72 |
| Rupture Width | 48 |
| Class Location Type | Class 1 Location |
| Could Be Hca | No |
| Pir Radius | 481 |
| Heat Damage Ind | No |
| Non Heat Damage Ind | No |
| Did Occur In Mca Ind | No |
| Est Cost Oper Paid | 0 |
| Est Cost Unintentional Release | 31453 |
| Est Cost Intentional Release | 0 |
| Est Cost Prop Damage | 736962 |
| Est Cost Emergency | 0 |
| Est Cost Other | 1427 |
| Est Cost Other Details | Repayment To Farmer/rancher Who Leased Land For Cattle. |
| Gas Cost In Mcf | 4.43 |
| Prpty | 769842 |
| Num Persons Hosp Not Ovnght | 0 |
| Num Injured Treated By Emt | 0 |
| Num Resident Building Affctd | 0 |
| Num Business Building Affctd | 0 |
| Wildlife Impact Ind | No |
| Accident Psig | 843 |
| Gas Flow In Pipe In Mcf | 28900 |
| Mop Psig | 845 |
| Mop Cfr Section | 192.619(A)(2) View CFR 49 §192 |
| Maop Established Date | 2005-06-01 00:00:00 |
| Maop Reversal Flow Ind | No |
| Accident Pressure | Pressure Did Not Exceed Maop |
| Pressure Restriction Ind | No |
| Gas Required Odorized Ind | No |
| Pipeline Function | Transmission In Storage Field |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | Yes |
| Scada Conf Ind | Yes |
| Accident Identifier | Notification From Emergency Responder |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | Controller actions did not affect the incident. |
| Employee Drug Test Ind | Yes |
| Contractor Drug Test Ind | No |
| Num Employees Tested | 4 |
| Num Employees Failed | 0 |
| Cause | Corrosion Failure |
| Cause Details | Internal Corrosion |
| Internal External | Internal Corrosion |
| Int Visual Exam Results | Other |
| Int Visual Exam Details | Pipe Wall Thinning Due To Internal Corrosion. Determined By Metallurgical Analysis. |
| Int Corrosive Commodity Ind | Yes |
| Int Metallurgical Basis Ind | Yes |
| Int Low Point Pipe Loc Ind | Yes |
| Corrosion Inhibitors | Yes |
| Corrosion Lining | No |
| Cleaning Dewatering | No |
| Corrosion Coupons | Yes |
| Preparer Name | T*** N******* |
| Preparer Title | Director - Regulatory Compliance |
| Preparer Email | T************@e*************.com |
| Preparer Telephone | 713-989-7126 |
| Authorizer Name | T*** N******* |
| Authorizer Title | Director - Regulatory Compliance |
| Authorizer Telephone | 713-989-7126 |
| Authorizer Email | T************@e*************.com |
| Narrative | On 10/03/22 at 00:18, the 24-inch st peter drip line in the waverly storage field failed resulting in a fire. The pipe appears to have failed at the 6 o'clock position on the south end of the pipe. Approximately 7.1 mmcf of natural gas was released. The pipeline was isolated and blowdown by area operations resulting in the fire being extinguished. Local emergency management closed roads and evacuated two residents near the failure site to prevent traffic from entering the area. The failed section of pipe was removed and the line was restarted on 10/06/22 at 11:00. The failed section of pipe was sent to third party laboratory for analysis. The results of the analysis indicated that the rupture occurred by ductile overload at the approximate 6:15 orientation in an area of significant wall thinning from internal corrosion. The internal corrosion that preceded the rupture was likely due to the presence of corrosive gases in the pipeline. To prevent recurrence, a new drip design was prepared to bring the drip above ground so it can be monitored more closely. |
External Resources
PHMSA pipeline safety insights.
Product