GTG incident on 2022-09-19 — TX

Operator
Enterprise Products Operating Llc
Cause
Corrosion Failure
Commodity
Natural Gas
Program
GTG
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$639,000
Incident datetime
2022-09-19 15:50
Report number
Location
TX
Narrative
At about 15:16hrs 19sep2022 enterprise control room was contacted by the nueces county sheriff department concerning a grass fire in the vicinity of an enterprise gas pipeline. The controller immediately dispatched field personnel to investigate. At about 15:50hrs field personnel arrived on site then contacted enterprise control room confirming a pipeline failure and fire. The local fire department were on site already. The fire was allowed to burn-out. At about 16:00hrs field personnel began closing manual valves; the last one (valve #3) was closed at 16:10hrs, totally isolating the rupture site. At about 17:30hrs the fire had extinguished itself, and we were able to safely inspect the site. The fire department did not evacuate landowners or close roads. The failure segment was cut-out; west side on 30sept2022, east side on 07oct2022. Both cut-outs were sent to the lab on 10oct2022. The abandonment of the pipeline was completed on 27feb2023. Based on a metallurgical analysis, external, general corrosion was the cause of the failure. The rrc was contacted on 19sep2022 at 17:06hrs. Trrc incident number 2706
Detailed record list
Report Received Date
2022-10-18 00:00:00
Iyear
2022
Report Number
20220110
Supplemental Number
37812
Report Type
Supplemental Final
Operator Id
Name
Enterprise Products Operating Llc
Operator Street Address
1100 Louisiana Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2022-09-19 15:16:00
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
Nrc Rpt Num
Nrc Rpt Datetime
2022-09-19 17:05:00
Additional Nrc Report Numbers
1347901
Commodity Released Type
Natural Gas
Unintentional Release
390
Intentional Release
0
Accompanying Liquid
11.9
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Status When Identified
Normal Operation, Includes Pauses During Maintenance
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2022-09-19 16:10:00
Restart Datetime
2023-02-27 15:00:00
Ignite Ind
Yes
Ignite Datetime
2022-09-19 15:16:00
How Extinguished
Allowed To Burn Out
Gas Consumed By Fire In Mcf
390
Explode Ind
Yes
Upstream Action Taken
Valve Closure
Upstream Valve Close Datetime
2022-09-19 16:00:00
Downstream Action Taken
Valve Closure
Downstream Vlv Close Datetime
2022-09-19 16:10:00
Num Pub Evacuated
2
Incident Identified Datetime
2022-09-19 15:50:00
On Site Datetime
2022-09-19 15:50:00
On Off Shore
Onshore
Onshore State Abbreviation
Tx
Onshore Postal Code
78343
Onshore City Name
Bishop
Onshore County Name
Nueces
Designated Location
Milepost
Designated Name
81+97
Pipe Fac Name
Luby Lateral
Segment Name
9d
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Aboveground
Incident Area Subtype
In Or Spanning An Open Ditch
Crossing
Yes
Water Crossing Ind
Yes
Water Type
Uncased
Water Name
Cotulla Ditch
Water Depth
Unknown
Water Subtype
Shoreline/bank/marsh Crossing
Crossing 100 Feet
No
Pipe Facility Type
Intrastate
System Part Involved
Onshore Pipeline, Including Valve Sites
Item Involved
Pipe
Pipe Type
Pipe Body
Pipe Diameter
10
Puddle Weld Ind
No
Pipe Wall Thickness
0.219
Pipe Smys
46000
Pipe Specification
Api-5l-X-46-46000
Pipe Seam Type
Longitudinal Erw - Low Frequency
Pipe Manufacturer
Unknown
Pipe Coating Type
Coal Tar
Coating Applied Ind
Unknown
Installation Year
1967
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Rupture
Rupture Orient
Circumferential
Rupture Length
12
Rupture Width
8
Class Location Type
Class 1 Location
Could Be Hca
No
Pir Radius
298
Heat Damage Ind
No
Non Heat Damage Ind
No
Did Occur In Mca Ind
No
Est Cost Oper Paid
500000
Est Cost Unintentional Release
3175
Est Cost Intentional Release
0
Est Cost Prop Damage
639000
Est Cost Emergency
0
Est Cost Other
0
Gas Cost In Mcf
8.14
Prpty
1142175
Num Persons Hosp Not Ovnght
2
Num Injured Treated By Emt
0
Num Resident Building Affctd
1
Num Business Building Affctd
0
Wildlife Impact Ind
No
Accident Psig
877
Gas Flow In Pipe In Mcf
149
Mop Psig
1114
Mop Cfr Section
192.619(A)(2)
Maop Established Date
1982-05-19 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Maop
Pressure Restriction Ind
No
Gas Required Odorized Ind
No
Upstream Valve Type Ind
Manual
Downstream Valve Type Ind
Manual
Length Segment Isolated
9276
Internal Inspection Ind
No
Other Inspection Ind
Yes
Internal Inspection Details
No Launch And Receiver Facilities
Operation Complications Ind
No
Pipeline Function
Type C Gathering
Scada In Place Ind
No
Accident Identifier
Notification From Emergency Responder
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
External Corrosion
Internal External
External Corrosion
Visual Exam Results
General Corrosion
Atmosphere Corrosion Ind
Yes
Metallurgical Basis Ind
Yes
Underground Location
No
Externally Coated
Yes
Prior Damage
Yes
Collected Data Ind
No
Has Hydrtst Conduc Before Ind
Yes
Hydrtst Most Rcnt Year
1982
Hydrtst Most Rcnt Pressure
1225
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
A*** S******
Preparer Title
Sr. Pipeline Compliance Specialist
Preparer Email
A*******@e****.com
Preparer Telephone
713-381-6741
Authorizer Name
N*** T*****
Authorizer Title
Sr. Compliance Manager
Authorizer Telephone
713-381-2493
Authorizer Email
N*******@e****.com
Narrative
At about 15:16hrs 19sep2022 enterprise control room was contacted by the nueces county sheriff department concerning a grass fire in the vicinity of an enterprise gas pipeline. The controller immediately dispatched field personnel to investigate. At about 15:50hrs field personnel arrived on site then contacted enterprise control room confirming a pipeline failure and fire. The local fire department were on site already. The fire was allowed to burn-out. At about 16:00hrs field personnel began closing manual valves; the last one (valve #3) was closed at 16:10hrs, totally isolating the rupture site. At about 17:30hrs the fire had extinguished itself, and we were able to safely inspect the site. The fire department did not evacuate landowners or close roads. The failure segment was cut-out; west side on 30sept2022, east side on 07oct2022. Both cut-outs were sent to the lab on 10oct2022. The abandonment of the pipeline was completed on 27feb2023. Based on a metallurgical analysis, external, general corrosion was the cause of the failure. The rrc was contacted on 19sep2022 at 17:06hrs. Trrc incident number 2706
Report Received Date 2022-10-18 00:00:00
Iyear 2022
Report Number 20220110
Supplemental Number 37812
Report Type Supplemental Final
Operator Id 31618 PHMSA Enforcement
Name Enterprise Products Operating Llc
Operator Street Address 1100 Louisiana Street
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77002
Local Datetime 2022-09-19 15:16:00
Time Zone Central
Daylight Savings Ind Yes
Location Latitude 27.591771 Google Maps OpenStreetMap
Location Longitude -97.610593 Google Maps OpenStreetMap
Nrc Rpt Num 1347704 NRC Report How to search
Nrc Rpt Datetime 2022-09-19 17:05:00
Additional Nrc Report Numbers 1347901
Commodity Released Type Natural Gas
Unintentional Release 390
Intentional Release 0
Accompanying Liquid 11.9
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Status When Identified Normal Operation, Includes Pauses During Maintenance
Shutdown Due Accident Ind Yes
Shutdown Datetime 2022-09-19 16:10:00
Restart Datetime 2023-02-27 15:00:00
Ignite Ind Yes
Ignite Datetime 2022-09-19 15:16:00
How Extinguished Allowed To Burn Out
Gas Consumed By Fire In Mcf 390
Explode Ind Yes
Upstream Action Taken Valve Closure
Upstream Valve Close Datetime 2022-09-19 16:00:00
Downstream Action Taken Valve Closure
Downstream Vlv Close Datetime 2022-09-19 16:10:00
Num Pub Evacuated 2
Incident Identified Datetime 2022-09-19 15:50:00
On Site Datetime 2022-09-19 15:50:00
On Off Shore Onshore
Onshore State Abbreviation Tx
Onshore Postal Code 78343
Onshore City Name Bishop
Onshore County Name Nueces
Designated Location Milepost
Designated Name 81+97
Pipe Fac Name Luby Lateral
Segment Name 9d
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Aboveground
Incident Area Subtype In Or Spanning An Open Ditch
Crossing Yes
Water Crossing Ind Yes
Water Type Uncased
Water Name Cotulla Ditch
Water Depth Unknown
Water Subtype Shoreline/bank/marsh Crossing
Crossing 100 Feet No
Pipe Facility Type Intrastate
System Part Involved Onshore Pipeline, Including Valve Sites
Item Involved Pipe
Pipe Type Pipe Body
Pipe Diameter 10
Puddle Weld Ind No
Pipe Wall Thickness 0.219
Pipe Smys 46000
Pipe Specification Api-5l-X-46-46000
Pipe Seam Type Longitudinal Erw - Low Frequency
Pipe Manufacturer Unknown
Pipe Coating Type Coal Tar
Coating Applied Ind Unknown
Installation Year 1967
Manufactured Year Unknown
Material Involved Carbon Steel
Release Type Rupture
Rupture Orient Circumferential
Rupture Length 12
Rupture Width 8
Class Location Type Class 1 Location
Could Be Hca No
Pir Radius 298
Heat Damage Ind No
Non Heat Damage Ind No
Did Occur In Mca Ind No
Est Cost Oper Paid 500000
Est Cost Unintentional Release 3175
Est Cost Intentional Release 0
Est Cost Prop Damage 639000
Est Cost Emergency 0
Est Cost Other 0
Gas Cost In Mcf 8.14
Prpty 1142175
Num Persons Hosp Not Ovnght 2
Num Injured Treated By Emt 0
Num Resident Building Affctd 1
Num Business Building Affctd 0
Wildlife Impact Ind No
Accident Psig 877
Gas Flow In Pipe In Mcf 149
Mop Psig 1114
Mop Cfr Section 192.619(A)(2) View CFR 49 §192
Maop Established Date 1982-05-19 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Maop
Pressure Restriction Ind No
Gas Required Odorized Ind No
Upstream Valve Type Ind Manual
Downstream Valve Type Ind Manual
Length Segment Isolated 9276
Internal Inspection Ind No
Other Inspection Ind Yes
Internal Inspection Details No Launch And Receiver Facilities
Operation Complications Ind No
Pipeline Function Type C Gathering
Scada In Place Ind No
Accident Identifier Notification From Emergency Responder
Investigation Status No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Corrosion Failure
Cause Details External Corrosion
Internal External External Corrosion
Visual Exam Results General Corrosion
Atmosphere Corrosion Ind Yes
Metallurgical Basis Ind Yes
Underground Location No
Externally Coated Yes
Prior Damage Yes
Collected Data Ind No
Has Hydrtst Conduc Before Ind Yes
Hydrtst Most Rcnt Year 1982
Hydrtst Most Rcnt Pressure 1225
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Preparer Name A*** S******
Preparer Title Sr. Pipeline Compliance Specialist
Preparer Email A*******@e****.com
Preparer Telephone 713-381-6741
Authorizer Name N*** T*****
Authorizer Title Sr. Compliance Manager
Authorizer Telephone 713-381-2493
Authorizer Email N*******@e****.com
Narrative At about 15:16hrs 19sep2022 enterprise control room was contacted by the nueces county sheriff department concerning a grass fire in the vicinity of an enterprise gas pipeline. The controller immediately dispatched field personnel to investigate. At about 15:50hrs field personnel arrived on site then contacted enterprise control room confirming a pipeline failure and fire. The local fire department were on site already. The fire was allowed to burn-out. At about 16:00hrs field personnel began closing manual valves; the last one (valve #3) was closed at 16:10hrs, totally isolating the rupture site. At about 17:30hrs the fire had extinguished itself, and we were able to safely inspect the site. The fire department did not evacuate landowners or close roads. The failure segment was cut-out; west side on 30sept2022, east side on 07oct2022. Both cut-outs were sent to the lab on 10oct2022. The abandonment of the pipeline was completed on 27feb2023. Based on a metallurgical analysis, external, general corrosion was the cause of the failure. The rrc was contacted on 19sep2022 at 17:06hrs. Trrc incident number 2706