HL incident on 2022-03-31 — TX

Operator
Products (Se) Pipe Line Corporation
Cause
Material Failure Of Pipe Or Weld
Commodity
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$65,000
Incident datetime
2022-03-31 14:30
Report number
Location
TX
Narrative
3/31/2022 - at kinder morgan's products (se) pipeline corps. Pure terminal in montgomery alabama, montgomery county, a local km employee responded to an explosive atmosphere detector (ead) alarm received and discovered stained gravel in the manifold area. The pipeline was shut down and the station was isolated. After excavating the area, the leak source was identified as a fitting on the facility prover. Due to anticipated costs exceeding $50k a call was made to the national response center on 4/1/2022 at 15:29 (nrc#1332504). The weld on the fitting failed due to fatigue caused by normal operation of the prover and prover ball. The fitting was an original fitting from date of installation. The repair was made by encapsulating the original fitting.
Detailed record list
Report Received Date
2022-04-29 00:00:00
Iyear
2022
Report Number
20220093
Supplemental Number
36629
Report Type
Original Final
Operator Id
Name
Products (Se) Pipe Line Corporation
Operator Street Address
1001 Louisiana St Suite 1000
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2022-03-31 12:42:00
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
Commodity Released Type
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype
Gasoline (Non-Ethanol)
Unintentional Release Bbls
5.12
Recovered Bbls
5.12
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Scada-Based Information (Such As Alarm(S), Alert(S), Event(S), And/or Volume Or Pack Calculations)
Incident Identified Datetime
2022-03-31 14:30:00
System Part Involved
Onshore Pump/meter Station Equipment And Piping
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2022-03-31 14:15:00
Restart Datetime
2022-04-01 19:47:00
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Initial Responder Com Datetime
2022-03-31 15:05:00
On Site Datetime
2022-03-31 14:30:00
Confirmed Discovery Datetime
2022-03-31 22:35:00
Nrc Rpt Datetime
2022-04-01 15:29:00
Nrc Rpt Num
Additional Nrc Report Numbers
1332552
Ignite Ind
No
Notify Qualified Indiv Ind
Yes
Qualified Indiv Notif Datetime
2022-03-31 14:30:00
Oil Spill Removal Org Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Products (Se) Pipe Line Corp. / Pure Terminal
Segment Name
8mg Pipeline
Onshore State Abbreviation
Al
Onshore Postal Code
36108
Onshore City Name
Montogmery
Onshore County Name
Montgomery
Designated Location
Milepost
Designated Name
69.18
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
12
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Weld, Including Heat-Affected Zone
Weld Subtype
Fillet Weld
Installation Year
1970
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
Yes
Commercially Nav Ind
Yes
Commercially Nav Yes No
Yes
High Pop Ind
Yes
High Pop Yes No
Yes
Other Pop Ind
Yes
Other Pop Yes No
Yes
Usa Drinking Ind
Yes
Usa Drinking Yes No
Yes
Usa Ecological Ind
Yes
Usa Ecological Yes No
Yes
Est Cost Oper Paid
0
Est Cost Gas Released
638
Est Cost Prop Damage
65000
Est Cost Emergency
65000
Est Cost Environmental
20000
Est Cost Other
0
Prpty
150638
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
208
Mop Psig
720
Mop Cfr Section
Component Design Pressure �195.406(A)(2)
Maop Established Date
1970-01-01 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
Yes
Scada Conf Ind
Yes
Cpm In Place Ind
No
Investigation Status
Yes, specify investigation result(s): (select all that apply)
Invest Schedule Ind
Yes
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Material Failure Of Pipe Or Weld
Cause Details
Design-, Construction-, Installation-, Or Fabrication-Related
Field Exam Ind
Yes
Failure Type
Design-, Construction-, Installation-, Or Fabrication-Related
Fatigue Vibr Related
Yes
Failure Subtype
Other
Fatigue Vibr Related Other
Fatigued Caused By Normal Operation Of Prover Ball.
Additional Crack Ind
Yes
Collected Data Ind
No
Has Hydrtst Conduc Before Ind
No
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
J**** S***** P*******
Preparer Title
Specialist - Technical Compliance Code St Sr Ii
Preparer Email
J*************@k***********.com
Preparer Telephone
7134207004
Prepared Date
2022-04-29 00:00:00
Local Contact Name
S**** P***
Local Contact Email
S*********@k***********.com
Local Contact Telephone
6016983921
Authorizer Name
D******* S*******
Authorizer Telephone
7134206496
Authorizer Title
Manager - Compliance Code St
Authorizer Email
D****************@k***********.com
Narrative
3/31/2022 - at kinder morgan's products (se) pipeline corps. Pure terminal in montgomery alabama, montgomery county, a local km employee responded to an explosive atmosphere detector (ead) alarm received and discovered stained gravel in the manifold area. The pipeline was shut down and the station was isolated. After excavating the area, the leak source was identified as a fitting on the facility prover. Due to anticipated costs exceeding $50k a call was made to the national response center on 4/1/2022 at 15:29 (nrc#1332504). The weld on the fitting failed due to fatigue caused by normal operation of the prover and prover ball. The fitting was an original fitting from date of installation. The repair was made by encapsulating the original fitting.
Report Received Date 2022-04-29 00:00:00
Iyear 2022
Report Number 20220093
Supplemental Number 36629
Report Type Original Final
Operator Id 15674 PHMSA Enforcement
Name Products (Se) Pipe Line Corporation
Operator Street Address 1001 Louisiana St Suite 1000
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77002
Local Datetime 2022-03-31 12:42:00
Time Zone Central
Daylight Savings Ind Yes
Location Latitude 32.39942 Google Maps OpenStreetMap
Location Longitude -86.411246 Google Maps OpenStreetMap
Commodity Released Type Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype Gasoline (Non-Ethanol)
Unintentional Release Bbls 5.12
Recovered Bbls 5.12
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Scada-Based Information (Such As Alarm(S), Alert(S), Event(S), And/or Volume Or Pack Calculations)
Incident Identified Datetime 2022-03-31 14:30:00
System Part Involved Onshore Pump/meter Station Equipment And Piping
On Off Shore Onshore
Status When Identified Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind Yes
Shutdown Datetime 2022-03-31 14:15:00
Restart Datetime 2022-04-01 19:47:00
Communication State Fed Ind Yes
Party Initiated Communication Operator
Initial Responder Com Datetime 2022-03-31 15:05:00
On Site Datetime 2022-03-31 14:30:00
Confirmed Discovery Datetime 2022-03-31 22:35:00
Nrc Rpt Datetime 2022-04-01 15:29:00
Nrc Rpt Num 1332504 NRC Report How to search
Additional Nrc Report Numbers 1332552
Ignite Ind No
Notify Qualified Indiv Ind Yes
Qualified Indiv Notif Datetime 2022-03-31 14:30:00
Oil Spill Removal Org Ind No
Num Pub Evacuated 0
Pipe Fac Name Products (Se) Pipe Line Corp. / Pure Terminal
Segment Name 8mg Pipeline
Onshore State Abbreviation Al
Onshore Postal Code 36108
Onshore City Name Montogmery
Onshore County Name Montgomery
Designated Location Milepost
Designated Name 69.18
Federal No
Location Type Totally Contained On Operator-Controlled Property
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 12
Crossing No
Pipe Facility Type Interstate
Item Involved Weld, Including Heat-Affected Zone
Weld Subtype Fillet Weld
Installation Year 1970
Manufactured Year Unknown
Material Involved Carbon Steel
Release Type Leak
Leak Type Pinhole
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment No
Remediation Ind No
Water Contam Ind No
Could Be Hca Yes
Commodity Reached Hca Yes
Commercially Nav Ind Yes
Commercially Nav Yes No Yes
High Pop Ind Yes
High Pop Yes No Yes
Other Pop Ind Yes
Other Pop Yes No Yes
Usa Drinking Ind Yes
Usa Drinking Yes No Yes
Usa Ecological Ind Yes
Usa Ecological Yes No Yes
Est Cost Oper Paid 0
Est Cost Gas Released 638
Est Cost Prop Damage 65000
Est Cost Emergency 65000
Est Cost Environmental 20000
Est Cost Other 0
Prpty 150638
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Accident Psig 208
Mop Psig 720
Mop Cfr Section Component Design Pressure �195.406(A)(2) View CFR 49 §192
Maop Established Date 1970-01-01 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind Yes
Scada Conf Ind Yes
Cpm In Place Ind No
Investigation Status Yes, specify investigation result(s): (select all that apply)
Invest Schedule Ind Yes
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Material Failure Of Pipe Or Weld
Cause Details Design-, Construction-, Installation-, Or Fabrication-Related
Field Exam Ind Yes
Failure Type Design-, Construction-, Installation-, Or Fabrication-Related
Fatigue Vibr Related Yes
Failure Subtype Other
Fatigue Vibr Related Other Fatigued Caused By Normal Operation Of Prover Ball.
Additional Crack Ind Yes
Collected Data Ind No
Has Hydrtst Conduc Before Ind No
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Preparer Name J**** S***** P*******
Preparer Title Specialist - Technical Compliance Code St Sr Ii
Preparer Email J*************@k***********.com
Preparer Telephone 7134207004
Prepared Date 2022-04-29 00:00:00
Local Contact Name S**** P***
Local Contact Email S*********@k***********.com
Local Contact Telephone 6016983921
Authorizer Name D******* S*******
Authorizer Telephone 7134206496
Authorizer Title Manager - Compliance Code St
Authorizer Email D****************@k***********.com
Narrative 3/31/2022 - at kinder morgan's products (se) pipeline corps. Pure terminal in montgomery alabama, montgomery county, a local km employee responded to an explosive atmosphere detector (ead) alarm received and discovered stained gravel in the manifold area. The pipeline was shut down and the station was isolated. After excavating the area, the leak source was identified as a fitting on the facility prover. Due to anticipated costs exceeding $50k a call was made to the national response center on 4/1/2022 at 15:29 (nrc#1332504). The weld on the fitting failed due to fatigue caused by normal operation of the prover and prover ball. The fitting was an original fitting from date of installation. The repair was made by encapsulating the original fitting.

All rights reserved. Copyright © by ClearPHMSA