GTG incident on 2022-07-23 — TX

Operator
Sea Robin Pipeline Co
Cause
Corrosion Failure
Commodity
Natural Gas
Program
GTG
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$375,000
Incident datetime
2022-07-23 16:42
Report number
Location
TX
Narrative
7/23/22, sea robin gas control received notification of a sheen in the ei 330 block area. The third-party producer who observed the sheen notified the nrc and those who have lines in the area. 7/24/22, et made an overflight to confirm sheen. Findings were reported to the nrc at 17:36, nrc#1342409. 7/25/22, the producer who originally spotted the sheen has a dsv on contract and are in the process of investigating the source. They are just arriving in the field but will update US as they determine ownership. 7/26/22, the dsv shows the leak source is at a crossing between the sea robin west 8-inch line and a third party 6-inch line. Due to the limitations of the dsv that responded, they were unable to safely access the crossing to verify which line is at fault. The sea robin west 8-inch line is connected to the sea robin west 24-inch, which is currently in the process of depressurization due to the leaking fitting in smi128. That depressurization work will continue as will our attempts to locate a dsv with the needed capabilities. The nrc 48-hour update was made, and the report was updated with overflight findings. Nrc#1342624. 8/19/2022, we have been unable to source a dsv to respond to our incidents. The responsible party for this release is yet to be determined. 8/21/2022, energy transfer placed a call to the nrc to take ownership of the release and update responsible party to sea robin pipeline. Nrc# 1345136. Condensate found leaking from a pinhole leak at the 5 o'clock position. 8/22/2022, the repair clamp has been installed. Operations personnel beginning the pressurization of pipeline to perform leak checks at multiple stages. No leaks were observed by the divers or overflight personnel throughout each increase in pressure points. 8/23/22, the line was back to full pressure (equalized) at 16:39.
Detailed record list
Report Received Date
2022-08-19 00:00:00
Iyear
2022
Report Number
20220087
Supplemental Number
39728
Report Type
Supplemental Final
Operator Id
Name
Sea Robin Pipeline Co
Operator Street Address
1300 Main Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2022-07-23 16:42:00
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
Nrc Rpt Num
Nrc Rpt Datetime
2022-07-24 17:36:00
Additional Nrc Report Numbers
13,426,241,345,136
Commodity Released Type
Natural Gas
Unintentional Release
2647.87
Intentional Release
29414.76
Accompanying Liquid
28.89
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Status When Identified
Idle
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Initial Responder Com Datetime
2022-07-24 17:46:00
Ignite Ind
No
Upstream Action Taken
Operational Control
Upstream Oprtnl Cntrl Detail
Valves Already Closed Due To Previous Incident.
Downstream Action Taken
Operational Control
Downstream Oprtnl Cntrl Detail
Valves Already Closed Due To Previous Incident.
Num Pub Evacuated
0
Incident Identified Datetime
2022-07-23 16:42:00
On Site Datetime
2022-07-23 16:42:00
Confirmed Discovery Datetime
2022-08-21 13:45:00
On Off Shore
Offshore
Pipe Fac Name
Sea Robin Ei Block 330
Segment Name
Segment # 7109 Line 716-10-1
Off Water Depth
260
Off Accident Origin
On The Outer Continental Shelf (Ocs)
Ocs Type
Ocs-Gulf Of Mexico
Off Ocs Area
Eugene Island
Off Ocs Block
330
Off Area Accident Type
Below Water, Pipe Buried Or Jetted Below Seabed
Pipe Facility Type
Interstate
System Part Involved
Offshore Pipeline, Including Riser And Riser Bend
Item Involved
Pipe
Pipe Type
Pipe Body
Pipe Diameter
8.625
Puddle Weld Ind
No
Pipe Wall Thickness
0.438
Pipe Smys
24000
Pipe Specification
Api 5l X-52
Pipe Seam Type
Other
Pipe Seam Details
Unknown
Pipe Manufacturer
Unknown
Pipe Coating Type
Other
Pipe Coating Details
Mastic And Concrete
Coating Applied Ind
Yes
Installation Year
1973
Manufactured Year
1973
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Class Location Type
Class 1 Location
Could Be Hca
No
Pir Radius
165
Heat Damage Ind
No
Non Heat Damage Ind
No
Did Occur In Mca Ind
No
Est Cost Oper Paid
0
Est Cost Unintentional Release
21845
Est Cost Intentional Release
242672
Est Cost Prop Damage
375000
Est Cost Emergency
75000
Est Cost Other
0
Gas Cost In Mcf
8.25
Prpty
714517
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Wildlife Impact Ind
No
Accident Psig
735
Gas Flow In Pipe In Mcf
10
Mop Psig
1306
Mop Cfr Section
192.619(A)(1)
Maop Established Date
1977-01-01 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Maop
Pressure Restriction Ind
No
Gas Required Odorized Ind
No
Length Segment Isolated
31680
Internal Inspection Ind
No
Tight Mitered Ind
Yes
Operation Complications Ind
Yes
Low Flow Ind
Yes
Other Complications Ind
Yes
Inspect Comp Details
Multiple Diameter Pipe
Pipeline Function
Transmission System
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Accident Identifier
Other
Accident Details
Third Party Producer
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
A review of the accident determined that there were no control room actions that contributed to the event.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
Internal Corrosion
Internal External
Internal Corrosion
Int Visual Exam Results
Not Cut Open
Int Corrosive Commodity Ind
Yes
Int Field Exam Basis Ind
Yes
Int Low Point Pipe Loc Ind
Yes
Int Drop Out Loc Ind
Yes
Corrosion Inhibitors
Yes
Corrosion Lining
No
Cleaning Dewatering
No
Corrosion Coupons
Yes
Collected Data Ind
No
Has Hydrtst Conduc Before Ind
No
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
P**** W***
Preparer Title
Senior Specialist - Dot Compliance
Preparer Email
P*********@e*************.com
Preparer Telephone
409-202-3088
Authorizer Name
J***** D*******
Authorizer Title
Manager - Dot Compliance
Authorizer Telephone
713-989-5391
Authorizer Email
J**************@e*************.com
Narrative
7/23/22, sea robin gas control received notification of a sheen in the ei 330 block area. The third-party producer who observed the sheen notified the nrc and those who have lines in the area. 7/24/22, et made an overflight to confirm sheen. Findings were reported to the nrc at 17:36, nrc#1342409. 7/25/22, the producer who originally spotted the sheen has a dsv on contract and are in the process of investigating the source. They are just arriving in the field but will update US as they determine ownership. 7/26/22, the dsv shows the leak source is at a crossing between the sea robin west 8-inch line and a third party 6-inch line. Due to the limitations of the dsv that responded, they were unable to safely access the crossing to verify which line is at fault. The sea robin west 8-inch line is connected to the sea robin west 24-inch, which is currently in the process of depressurization due to the leaking fitting in smi128. That depressurization work will continue as will our attempts to locate a dsv with the needed capabilities. The nrc 48-hour update was made, and the report was updated with overflight findings. Nrc#1342624. 8/19/2022, we have been unable to source a dsv to respond to our incidents. The responsible party for this release is yet to be determined. 8/21/2022, energy transfer placed a call to the nrc to take ownership of the release and update responsible party to sea robin pipeline. Nrc# 1345136. Condensate found leaking from a pinhole leak at the 5 o'clock position. 8/22/2022, the repair clamp has been installed. Operations personnel beginning the pressurization of pipeline to perform leak checks at multiple stages. No leaks were observed by the divers or overflight personnel throughout each increase in pressure points. 8/23/22, the line was back to full pressure (equalized) at 16:39.
Report Received Date 2022-08-19 00:00:00
Iyear 2022
Report Number 20220087
Supplemental Number 39728
Report Type Supplemental Final
Operator Id 18152 PHMSA Enforcement
Name Sea Robin Pipeline Co
Operator Street Address 1300 Main Street
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77002
Local Datetime 2022-07-23 16:42:00
Time Zone Central
Daylight Savings Ind Yes
Location Latitude 28.248333 Google Maps OpenStreetMap
Location Longitude -91.693333 Google Maps OpenStreetMap
Nrc Rpt Num 1342409 NRC Report How to search
Nrc Rpt Datetime 2022-07-24 17:36:00
Additional Nrc Report Numbers 13,426,241,345,136
Commodity Released Type Natural Gas
Unintentional Release 2647.87
Intentional Release 29414.76
Accompanying Liquid 28.89
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Status When Identified Idle
Communication State Fed Ind Yes
Party Initiated Communication Operator
Initial Responder Com Datetime 2022-07-24 17:46:00
Ignite Ind No
Upstream Action Taken Operational Control
Upstream Oprtnl Cntrl Detail Valves Already Closed Due To Previous Incident.
Downstream Action Taken Operational Control
Downstream Oprtnl Cntrl Detail Valves Already Closed Due To Previous Incident.
Num Pub Evacuated 0
Incident Identified Datetime 2022-07-23 16:42:00
On Site Datetime 2022-07-23 16:42:00
Confirmed Discovery Datetime 2022-08-21 13:45:00
On Off Shore Offshore
Pipe Fac Name Sea Robin Ei Block 330
Segment Name Segment # 7109 Line 716-10-1
Off Water Depth 260
Off Accident Origin On The Outer Continental Shelf (Ocs)
Ocs Type Ocs-Gulf Of Mexico
Off Ocs Area Eugene Island
Off Ocs Block 330
Off Area Accident Type Below Water, Pipe Buried Or Jetted Below Seabed
Pipe Facility Type Interstate
System Part Involved Offshore Pipeline, Including Riser And Riser Bend
Item Involved Pipe
Pipe Type Pipe Body
Pipe Diameter 8.625
Puddle Weld Ind No
Pipe Wall Thickness 0.438
Pipe Smys 24000
Pipe Specification Api 5l X-52
Pipe Seam Type Other
Pipe Seam Details Unknown
Pipe Manufacturer Unknown
Pipe Coating Type Other
Pipe Coating Details Mastic And Concrete
Coating Applied Ind Yes
Installation Year 1973
Manufactured Year 1973
Material Involved Carbon Steel
Release Type Leak
Leak Type Pinhole
Class Location Type Class 1 Location
Could Be Hca No
Pir Radius 165
Heat Damage Ind No
Non Heat Damage Ind No
Did Occur In Mca Ind No
Est Cost Oper Paid 0
Est Cost Unintentional Release 21845
Est Cost Intentional Release 242672
Est Cost Prop Damage 375000
Est Cost Emergency 75000
Est Cost Other 0
Gas Cost In Mcf 8.25
Prpty 714517
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Wildlife Impact Ind No
Accident Psig 735
Gas Flow In Pipe In Mcf 10
Mop Psig 1306
Mop Cfr Section 192.619(A)(1) View CFR 49 §192
Maop Established Date 1977-01-01 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Maop
Pressure Restriction Ind No
Gas Required Odorized Ind No
Length Segment Isolated 31680
Internal Inspection Ind No
Tight Mitered Ind Yes
Operation Complications Ind Yes
Low Flow Ind Yes
Other Complications Ind Yes
Inspect Comp Details Multiple Diameter Pipe
Pipeline Function Transmission System
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Accident Identifier Other
Accident Details Third Party Producer
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details A review of the accident determined that there were no control room actions that contributed to the event.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Corrosion Failure
Cause Details Internal Corrosion
Internal External Internal Corrosion
Int Visual Exam Results Not Cut Open
Int Corrosive Commodity Ind Yes
Int Field Exam Basis Ind Yes
Int Low Point Pipe Loc Ind Yes
Int Drop Out Loc Ind Yes
Corrosion Inhibitors Yes
Corrosion Lining No
Cleaning Dewatering No
Corrosion Coupons Yes
Collected Data Ind No
Has Hydrtst Conduc Before Ind No
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Preparer Name P**** W***
Preparer Title Senior Specialist - Dot Compliance
Preparer Email P*********@e*************.com
Preparer Telephone 409-202-3088
Authorizer Name J***** D*******
Authorizer Title Manager - Dot Compliance
Authorizer Telephone 713-989-5391
Authorizer Email J**************@e*************.com
Narrative 7/23/22, sea robin gas control received notification of a sheen in the ei 330 block area. The third-party producer who observed the sheen notified the nrc and those who have lines in the area. 7/24/22, et made an overflight to confirm sheen. Findings were reported to the nrc at 17:36, nrc#1342409. 7/25/22, the producer who originally spotted the sheen has a dsv on contract and are in the process of investigating the source. They are just arriving in the field but will update US as they determine ownership. 7/26/22, the dsv shows the leak source is at a crossing between the sea robin west 8-inch line and a third party 6-inch line. Due to the limitations of the dsv that responded, they were unable to safely access the crossing to verify which line is at fault. The sea robin west 8-inch line is connected to the sea robin west 24-inch, which is currently in the process of depressurization due to the leaking fitting in smi128. That depressurization work will continue as will our attempts to locate a dsv with the needed capabilities. The nrc 48-hour update was made, and the report was updated with overflight findings. Nrc#1342624. 8/19/2022, we have been unable to source a dsv to respond to our incidents. The responsible party for this release is yet to be determined. 8/21/2022, energy transfer placed a call to the nrc to take ownership of the release and update responsible party to sea robin pipeline. Nrc# 1345136. Condensate found leaking from a pinhole leak at the 5 o'clock position. 8/22/2022, the repair clamp has been installed. Operations personnel beginning the pressurization of pipeline to perform leak checks at multiple stages. No leaks were observed by the divers or overflight personnel throughout each increase in pressure points. 8/23/22, the line was back to full pressure (equalized) at 16:39.

All rights reserved. Copyright © by ClearPHMSA