GD incident on 2022-10-11 — FL
Operator
Central Florida Gas Corp
Cause
Locating Issue
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$47,000
Incident datetime
2022-10-11 15:35
Report number
Location
FL, POLK
Narrative
On 10/11/22 drilling smart, directional bore contractor, hit a 6" pe gas main operated by central florida gas under the paving at adams st and bridgers ave in auburndale, florida. The 6" pe is in the area where there is an old abandoned 4" bare steel gas main. The contract locator for central florida gas was off on his markings. Drilling smart exposed the 4" bare steel and assumed it was the active gas main and bored deeper than that line and hit the active 6" pe gas main. Central florida gas responded and used pipe squeezers on both sides of the intersection to stop the flow of gas in this dual fed gas main and did not lose service to any customers. The point of damage was under the roadway paving and the actual damage could not be seen. On 10/12/22, a new piece of 6" pe was installed under the intersection via directional bore, tested and tied in. Gas was restored to that main on 10/14/22. On 11/1/22, the city of auburndale presented central florida gas with costs to restore the road base and paving at that intersection, pushing the damage cost above the PHMSA reporting threshold of $122,000. A notice was made to the national reporting center via telephone on 11/1/22 and a 48 hour follow up on 11/3/22. 12/28/2022 supplement correction made to part a (19) - incorrect nrc report number entered initially with a number left out. Correct nrc report number of 1351443 entered. Part j - excavation damage (excavation damage by third party) removed as not necessary since listed in g3. Changed contributing factor to incorrect operation (failure to follow procedures) due to contract locator being off on marks and not listing the type and size of gas main in the positive response for the locate ticket. The locator was off on the locate marks by a few feet. The excavator spotted a pipe several feet away in a grassy area and assumed it was the gas main and at a certain depth. They bored the road at a deeper depth and hit the live pe gas main. The pipe they dug up and spotted for depth was an old retired 4" bare steel gas main and not the live 6" pe gas main. The contractor locator technicians were brought in and instructed again to list the size and type of pipe on the positive response to marked locate tickets, per procedures, to ensure excavators are sure which pipes they are spotting. No other damage information or costs require updating.
Detailed record list
Occurred At
2022-10-11 15:35:00
Year
2022
Report Received Date
2022-11-08 00:00:00
Iyear
2022.0
Report Number
20220072.0
Supplemental Number
37520.0
Report Type
Supplemental Final
Operator Id
2188
Name
Central Florida Gas Corp
Operator Street Address
208 Wildlight Ave
Operator City Name
Yulee
Operator State Abbreviation
FL
Operator Postal Code
32097
Local Datetime
2022-10-11 15:35:00
Time Zone
Eastern
Daylight Savings Ind
No
Location Street Address
Adams St At Bridgers Ave
Location City Name
Auburndale
Location County Name
Polk
Location State Abbreviation
FL
Location Postal Code
33823
Location Latitude
28.06266
Location Longitude
-81.78036
Flow Cont Squeeze Off Ind
Yes
Nrc Rpt Datetime
2022-11-01 16:25:00
Nrc Rpt Num
1351443
Additional Nrc Report Numbers
1351654
Commodity Released Type
Natural Gas
Unintentional Release
2187.5
Intentional Release
0.0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Ignite Ind
No
Num Pub Evacuated
0.0
Incident Identified Datetime
2022-10-11 15:35:00
On Site Datetime
2022-10-11 16:00:00
Federal
No
Location Type
Public Property
Incident Area Type
Underground
Incident Area Subtype
Under Pavement
Depth Of Cover
96.0
Other Underground Facilities
No
Crossing
Yes
Road Crossing Ind
Yes
Road Type
Uncased
Pipe Facility Type
Investor Owned
System Part Involved
Main
Installation Year
2015.0
Manufactured Year
2015.0
Pipe Diameter
6.0
Pipe Specification
D2513
Pipe Manufacturer
Driscoplex
Material Involved
Plastic
Plastic Type
Polyethylene (Pe)
Plastic Sdr
11.5
Material Pe Pipe Code
2406
Release Type
Mechanical Puncture
Puncture Axial
2.0
Puncture Circum
2.0
Class Location Type
Class 3 Location
Est Cost Oper Paid
200000.0
Est Cost Prop Damage
47000.0
Est Cost Emergency
1500.0
Est Cost Other
0.0
Gas Cost In Mcf
5.0
Est Cost Unintentional Release
10938.0
Est Cost Intentional Release
0.0
Prpty
259438.0
Commercial Affected
0.0
Industrial Affected
0.0
Residences Affected
0.0
Num Persons Hosp Not Ovnght
0.0
Num Injured Treated By Emt
0.0
Num Resident Building Affctd
0.0
Num Business Building Affctd
0.0
Accident Psig
45.0
Normal Psig
50.0
Mop Psig
60.0
Mop Cfr Section
192.619(A)(2)
Maop Established Date
2015-10-13 00:00:00
Accident Pressure
Pressure Did Not Exceed Maop
Gas Odorized System Type
Injection Pump
Gas Odorized Lvl Not Msrd Ind
Yes
Scada In Place Ind
No
Accident Identifier
Notification From Emergency Responder
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Excavation Damage
Cause Details
Excavation Damage By Third Party
Ex Party Type
Excavation Damage By Third Party
Prior Notification Ind
Yes
One Call System Ind
Yes
State Law Exempt Ind
No
Notify Cga Dirt
Yes
Public Row Ind
Yes
Public Subtype
City Street
Excavator Type
Contractor
Excavator Equipment
Directional Drilling
Work Performed
Cable Tv
One Call Notified Ind
Yes
One Call Ticket Num
263201452
Locator Type
Contract Locator
Visible Marks
Yes
Service Interruption
No
Root Cause Category
Locating Issue
Root Cause Type
Facility Not Marked Due To Incomplete Marks At Damage Location
Io Follow Procedure Ind
Yes
Preparer Name
M****** M******
Preparer Email
M*******@f***.com
Preparer Telephone
863 224-0417
Local Contact Name
G***** F******
Local Contact Email
G*******@f***.com
Local Contact Telephone
863 209-5030
Authorizer Name
M****** M******
Authorizer Telephone
863 224-0417
Authorizer Email
M*******@f***.com
Narrative
On 10/11/22 drilling smart, directional bore contractor, hit a 6" pe gas main operated by central florida gas under the paving at adams st and bridgers ave in auburndale, florida. The 6" pe is in the area where there is an old abandoned 4" bare steel gas main. The contract locator for central florida gas was off on his markings. Drilling smart exposed the 4" bare steel and assumed it was the active gas main and bored deeper than that line and hit the active 6" pe gas main. Central florida gas responded and used pipe squeezers on both sides of the intersection to stop the flow of gas in this dual fed gas main and did not lose service to any customers. The point of damage was under the roadway paving and the actual damage could not be seen. On 10/12/22, a new piece of 6" pe was installed under the intersection via directional bore, tested and tied in. Gas was restored to that main on 10/14/22. On 11/1/22, the city of auburndale presented central florida gas with costs to restore the road base and paving at that intersection, pushing the damage cost above the PHMSA reporting threshold of $122,000. A notice was made to the national reporting center via telephone on 11/1/22 and a 48 hour follow up on 11/3/22. 12/28/2022 supplement correction made to part a (19) - incorrect nrc report number entered initially with a number left out. Correct nrc report number of 1351443 entered. Part j - excavation damage (excavation damage by third party) removed as not necessary since listed in g3. Changed contributing factor to incorrect operation (failure to follow procedures) due to contract locator being off on marks and not listing the type and size of gas main in the positive response for the locate ticket. The locator was off on the locate marks by a few feet. The excavator spotted a pipe several feet away in a grassy area and assumed it was the gas main and at a certain depth. They bored the road at a deeper depth and hit the live pe gas main. The pipe they dug up and spotted for depth was an old retired 4" bare steel gas main and not the live 6" pe gas main. The contractor locator technicians were brought in and instructed again to list the size and type of pipe on the positive response to marked locate tickets, per procedures, to ensure excavators are sure which pipes they are spotting. No other damage information or costs require updating.
| Occurred At | 2022-10-11 15:35:00 |
|---|---|
| Year | 2022 |
| Report Received Date | 2022-11-08 00:00:00 |
| Iyear | 2022.0 |
| Report Number | 20220072.0 |
| Supplemental Number | 37520.0 |
| Report Type | Supplemental Final |
| Operator Id | 2188 PHMSA Enforcement |
| Name | Central Florida Gas Corp |
| Operator Street Address | 208 Wildlight Ave |
| Operator City Name | Yulee |
| Operator State Abbreviation | FL |
| Operator Postal Code | 32097 |
| Local Datetime | 2022-10-11 15:35:00 |
| Time Zone | Eastern |
| Daylight Savings Ind | No |
| Location Street Address | Adams St At Bridgers Ave |
| Location City Name | Auburndale |
| Location County Name | Polk |
| Location State Abbreviation | FL |
| Location Postal Code | 33823 |
| Location Latitude | 28.06266 Google Maps OpenStreetMap |
| Location Longitude | -81.78036 Google Maps OpenStreetMap |
| Flow Cont Squeeze Off Ind | Yes |
| Nrc Rpt Datetime | 2022-11-01 16:25:00 |
| Nrc Rpt Num | 1351443 NRC Report How to search |
| Additional Nrc Report Numbers | 1351654 |
| Commodity Released Type | Natural Gas |
| Unintentional Release | 2187.5 |
| Intentional Release | 0.0 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Ignite Ind | No |
| Num Pub Evacuated | 0.0 |
| Incident Identified Datetime | 2022-10-11 15:35:00 |
| On Site Datetime | 2022-10-11 16:00:00 |
| Federal | No |
| Location Type | Public Property |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Pavement |
| Depth Of Cover | 96.0 |
| Other Underground Facilities | No |
| Crossing | Yes |
| Road Crossing Ind | Yes |
| Road Type | Uncased |
| Pipe Facility Type | Investor Owned |
| System Part Involved | Main |
| Installation Year | 2015.0 |
| Manufactured Year | 2015.0 |
| Pipe Diameter | 6.0 |
| Pipe Specification | D2513 |
| Pipe Manufacturer | Driscoplex |
| Material Involved | Plastic |
| Plastic Type | Polyethylene (Pe) |
| Plastic Sdr | 11.5 |
| Material Pe Pipe Code | 2406 |
| Release Type | Mechanical Puncture |
| Puncture Axial | 2.0 |
| Puncture Circum | 2.0 |
| Class Location Type | Class 3 Location |
| Est Cost Oper Paid | 200000.0 |
| Est Cost Prop Damage | 47000.0 |
| Est Cost Emergency | 1500.0 |
| Est Cost Other | 0.0 |
| Gas Cost In Mcf | 5.0 |
| Est Cost Unintentional Release | 10938.0 |
| Est Cost Intentional Release | 0.0 |
| Prpty | 259438.0 |
| Commercial Affected | 0.0 |
| Industrial Affected | 0.0 |
| Residences Affected | 0.0 |
| Num Persons Hosp Not Ovnght | 0.0 |
| Num Injured Treated By Emt | 0.0 |
| Num Resident Building Affctd | 0.0 |
| Num Business Building Affctd | 0.0 |
| Accident Psig | 45.0 |
| Normal Psig | 50.0 |
| Mop Psig | 60.0 |
| Mop Cfr Section | 192.619(A)(2) View CFR 49 §192 |
| Maop Established Date | 2015-10-13 00:00:00 |
| Accident Pressure | Pressure Did Not Exceed Maop |
| Gas Odorized System Type | Injection Pump |
| Gas Odorized Lvl Not Msrd Ind | Yes |
| Scada In Place Ind | No |
| Accident Identifier | Notification From Emergency Responder |
| Investigation Status | No, the facility was not monitored by a controller(s) at the time of the incident |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Excavation Damage |
| Cause Details | Excavation Damage By Third Party |
| Ex Party Type | Excavation Damage By Third Party |
| Prior Notification Ind | Yes |
| One Call System Ind | Yes |
| State Law Exempt Ind | No |
| Notify Cga Dirt | Yes |
| Public Row Ind | Yes |
| Public Subtype | City Street |
| Excavator Type | Contractor |
| Excavator Equipment | Directional Drilling |
| Work Performed | Cable Tv |
| One Call Notified Ind | Yes |
| One Call Ticket Num | 263201452 |
| Locator Type | Contract Locator |
| Visible Marks | Yes |
| Service Interruption | No |
| Root Cause Category | Locating Issue |
| Root Cause Type | Facility Not Marked Due To Incomplete Marks At Damage Location |
| Io Follow Procedure Ind | Yes |
| Preparer Name | M****** M****** |
| Preparer Email | M*******@f***.com |
| Preparer Telephone | 863 224-0417 |
| Local Contact Name | G***** F****** |
| Local Contact Email | G*******@f***.com |
| Local Contact Telephone | 863 209-5030 |
| Authorizer Name | M****** M****** |
| Authorizer Telephone | 863 224-0417 |
| Authorizer Email | M*******@f***.com |
| Narrative | On 10/11/22 drilling smart, directional bore contractor, hit a 6" pe gas main operated by central florida gas under the paving at adams st and bridgers ave in auburndale, florida. The 6" pe is in the area where there is an old abandoned 4" bare steel gas main. The contract locator for central florida gas was off on his markings. Drilling smart exposed the 4" bare steel and assumed it was the active gas main and bored deeper than that line and hit the active 6" pe gas main. Central florida gas responded and used pipe squeezers on both sides of the intersection to stop the flow of gas in this dual fed gas main and did not lose service to any customers. The point of damage was under the roadway paving and the actual damage could not be seen. On 10/12/22, a new piece of 6" pe was installed under the intersection via directional bore, tested and tied in. Gas was restored to that main on 10/14/22. On 11/1/22, the city of auburndale presented central florida gas with costs to restore the road base and paving at that intersection, pushing the damage cost above the PHMSA reporting threshold of $122,000. A notice was made to the national reporting center via telephone on 11/1/22 and a 48 hour follow up on 11/3/22. 12/28/2022 supplement correction made to part a (19) - incorrect nrc report number entered initially with a number left out. Correct nrc report number of 1351443 entered. Part j - excavation damage (excavation damage by third party) removed as not necessary since listed in g3. Changed contributing factor to incorrect operation (failure to follow procedures) due to contract locator being off on marks and not listing the type and size of gas main in the positive response for the locate ticket. The locator was off on the locate marks by a few feet. The excavator spotted a pipe several feet away in a grassy area and assumed it was the gas main and at a certain depth. They bored the road at a deeper depth and hit the live pe gas main. The pipe they dug up and spotted for depth was an old retired 4" bare steel gas main and not the live 6" pe gas main. The contractor locator technicians were brought in and instructed again to list the size and type of pipe on the positive response to marked locate tickets, per procedures, to ensure excavators are sure which pipes they are spotting. No other damage information or costs require updating. |