Incident details
Operator, cause, commodity and consequences with raw source fields.
GD incident on 2022-08-24 — NC
Operator
Public Service Co Of North Carolina
Cause
Notification Issue
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$210,000
Incident datetime
2022-08-24 13:05
Report number
Location
NC, WAKE
Narrative
On august 24th, 2022, at approximately 1:00 pm, dominion energy north carolina (denc) responded to a ruptured gas main near the intersection of I-40 and rock quarry road, in raleigh, nc. When the denc first responder arrived, emergency responders had already taken control of the area. The third-party excavator, a subcontractor of the company doing work on the interstate, had pierced the 12-in steel, distribution pressure main while installing sound barrier panels along the interstate row. The excavator did not have a locate ticket. The contractor did call in a locate request after the main had been damaged. The leak was stopped by installing stopper fittings at approximately 12:30 am. Gas blew for approximately 12 hours. Denc management decided to make a PHMSA notification due to the concern that our repair costs would exceed $129,300 and that this event would be considered significant in nature. Repairs have been completed and the line is back in service.
Detailed record list
Occurred At
2022-08-24 13:05:00
Year
2022
Report Received Date
2022-09-22 00:00:00
Iyear
2022.0
Report Number
20220061.0
Supplemental Number
37148.0
Report Type
Original Final
Operator Id
15938
Name
Public Service Co Of North Carolina
Operator Street Address
800 Gaston Road
Operator City Name
Gastonia
Operator State Abbreviation
NC
Operator Postal Code
28056
Local Datetime
2022-08-24 13:00:00
Time Zone
Eastern
Daylight Savings Ind
Yes
Location Street Address
I40 & Rock Quarry Rd
Location City Name
Raleigh
Location County Name
Wake
Location State Abbreviation
NC
Location Postal Code
27610
Location Latitude
35.747176
Location Longitude
-78.594035
Flow Cont Stopple Fitng Ind
Yes
Nrc Rpt Datetime
2022-08-24 19:04:00
Nrc Rpt Num
1345455
Additional Nrc Report Numbers
1345507
Commodity Released Type
Natural Gas
Unintentional Release
1886.0
Intentional Release
0.0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Ignite Ind
No
Num Pub Evacuated
0.0
Incident Identified Datetime
2022-08-24 13:05:00
Communication State Fed Ind
No
On Site Datetime
2022-08-24 13:31:00
Federal
No
Location Type
Public Property
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
120.0
Other Underground Facilities
No
Crossing
No
Pipe Facility Type
Investor Owned
System Part Involved
Main
Installation Year
2020.0
Pipe Diameter
12.0
Pipe Specification
Api 5l
Pipe Manufacturer
Unknown
Material Involved
Steel
Steel Seam Type
Longitudinal Erw - High Frequency
Wt Steel
0.25
Release Type
Mechanical Puncture
Puncture Axial
1.5
Puncture Circum
1.5
Class Location Type
Class 3 Location
Est Cost Oper Paid
0.0
Est Cost Prop Damage
210000.0
Est Cost Emergency
15000.0
Est Cost Other
0.0
Gas Cost In Mcf
5.75
Est Cost Unintentional Release
10845.0
Est Cost Intentional Release
0.0
Prpty
235845.0
Commercial Affected
0.0
Industrial Affected
0.0
Residences Affected
2.0
Num Persons Hosp Not Ovnght
0.0
Num Injured Treated By Emt
0.0
Num Resident Building Affctd
2.0
Num Business Building Affctd
0.0
Accident Psig
55.0
Normal Psig
55.0
Mop Psig
60.0
Mop Cfr Section
192.621 M
Maop Established Date
2020-03-18 00:00:00
Accident Pressure
Pressure Did Not Exceed Maop
Gas Odorized System Type
Odorized By Others
Gas Odorized Lvl Not Msrd Ind
Yes
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Scada was not required to identify the failure.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Excavation Damage
Cause Details
Excavation Damage By Third Party
Ex Party Type
Excavation Damage By Third Party
Prior Notification Ind
No
State Law Exempt Ind
No
Notify Cga Dirt
Yes
Public Row Ind
Yes
Public Subtype
Interstate Highway
Excavator Type
Contractor
Excavator Equipment
Auger
Work Performed
Fencing
One Call Notified Ind
No
Service Interruption
Yes
Service Interruption Hours
10.0
Root Cause Category
Notification Issue
Root Cause Type
No Notification Made To The One-Call Center/811
Preparer Name
M*** N***
Preparer Title
Manager - Integrity And Compliance
Preparer Email
M********@d*************.com
Preparer Telephone
704-810-3224
Local Contact Name
C***** R***
Local Contact Email
C**********@d*************.com
Local Contact Telephone
919-836-2448
Authorizer Name
S**** S*******
Authorizer Title
Director - Gas Operations
Authorizer Telephone
704-810-3230
Authorizer Email
S*************@d*************.com
Narrative
On august 24th, 2022, at approximately 1:00 pm, dominion energy north carolina (denc) responded to a ruptured gas main near the intersection of I-40 and rock quarry road, in raleigh, nc. When the denc first responder arrived, emergency responders had already taken control of the area. The third-party excavator, a subcontractor of the company doing work on the interstate, had pierced the 12-in steel, distribution pressure main while installing sound barrier panels along the interstate row. The excavator did not have a locate ticket. The contractor did call in a locate request after the main had been damaged. The leak was stopped by installing stopper fittings at approximately 12:30 am. Gas blew for approximately 12 hours. Denc management decided to make a PHMSA notification due to the concern that our repair costs would exceed $129,300 and that this event would be considered significant in nature. Repairs have been completed and the line is back in service.
| Occurred At | 2022-08-24 13:05:00 |
|---|---|
| Year | 2022 |
| Report Received Date | 2022-09-22 00:00:00 |
| Iyear | 2022.0 |
| Report Number | 20220061.0 |
| Supplemental Number | 37148.0 |
| Report Type | Original Final |
| Operator Id | 15938 PHMSA Enforcement |
| Name | Public Service Co Of North Carolina |
| Operator Street Address | 800 Gaston Road |
| Operator City Name | Gastonia |
| Operator State Abbreviation | NC |
| Operator Postal Code | 28056 |
| Local Datetime | 2022-08-24 13:00:00 |
| Time Zone | Eastern |
| Daylight Savings Ind | Yes |
| Location Street Address | I40 & Rock Quarry Rd |
| Location City Name | Raleigh |
| Location County Name | Wake |
| Location State Abbreviation | NC |
| Location Postal Code | 27610 |
| Location Latitude | 35.747176 Google Maps OpenStreetMap |
| Location Longitude | -78.594035 Google Maps OpenStreetMap |
| Flow Cont Stopple Fitng Ind | Yes |
| Nrc Rpt Datetime | 2022-08-24 19:04:00 |
| Nrc Rpt Num | 1345455 NRC Report How to search |
| Additional Nrc Report Numbers | 1345507 |
| Commodity Released Type | Natural Gas |
| Unintentional Release | 1886.0 |
| Intentional Release | 0.0 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Ignite Ind | No |
| Num Pub Evacuated | 0.0 |
| Incident Identified Datetime | 2022-08-24 13:05:00 |
| Communication State Fed Ind | No |
| On Site Datetime | 2022-08-24 13:31:00 |
| Federal | No |
| Location Type | Public Property |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Soil |
| Depth Of Cover | 120.0 |
| Other Underground Facilities | No |
| Crossing | No |
| Pipe Facility Type | Investor Owned |
| System Part Involved | Main |
| Installation Year | 2020.0 |
| Pipe Diameter | 12.0 |
| Pipe Specification | Api 5l |
| Pipe Manufacturer | Unknown |
| Material Involved | Steel |
| Steel Seam Type | Longitudinal Erw - High Frequency |
| Wt Steel | 0.25 |
| Release Type | Mechanical Puncture |
| Puncture Axial | 1.5 |
| Puncture Circum | 1.5 |
| Class Location Type | Class 3 Location |
| Est Cost Oper Paid | 0.0 |
| Est Cost Prop Damage | 210000.0 |
| Est Cost Emergency | 15000.0 |
| Est Cost Other | 0.0 |
| Gas Cost In Mcf | 5.75 |
| Est Cost Unintentional Release | 10845.0 |
| Est Cost Intentional Release | 0.0 |
| Prpty | 235845.0 |
| Commercial Affected | 0.0 |
| Industrial Affected | 0.0 |
| Residences Affected | 2.0 |
| Num Persons Hosp Not Ovnght | 0.0 |
| Num Injured Treated By Emt | 0.0 |
| Num Resident Building Affctd | 2.0 |
| Num Business Building Affctd | 0.0 |
| Accident Psig | 55.0 |
| Normal Psig | 55.0 |
| Mop Psig | 60.0 |
| Mop Cfr Section | 192.621 M View CFR 49 §192 |
| Maop Established Date | 2020-03-18 00:00:00 |
| Accident Pressure | Pressure Did Not Exceed Maop |
| Gas Odorized System Type | Odorized By Others |
| Gas Odorized Lvl Not Msrd Ind | Yes |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | No |
| Accident Identifier | Local Operating Personnel, Including Contractors |
| Operator Type | Operator Employee |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | Scada was not required to identify the failure. |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Excavation Damage |
| Cause Details | Excavation Damage By Third Party |
| Ex Party Type | Excavation Damage By Third Party |
| Prior Notification Ind | No |
| State Law Exempt Ind | No |
| Notify Cga Dirt | Yes |
| Public Row Ind | Yes |
| Public Subtype | Interstate Highway |
| Excavator Type | Contractor |
| Excavator Equipment | Auger |
| Work Performed | Fencing |
| One Call Notified Ind | No |
| Service Interruption | Yes |
| Service Interruption Hours | 10.0 |
| Root Cause Category | Notification Issue |
| Root Cause Type | No Notification Made To The One-Call Center/811 |
| Preparer Name | M*** N*** |
| Preparer Title | Manager - Integrity And Compliance |
| Preparer Email | M********@d*************.com |
| Preparer Telephone | 704-810-3224 |
| Local Contact Name | C***** R*** |
| Local Contact Email | C**********@d*************.com |
| Local Contact Telephone | 919-836-2448 |
| Authorizer Name | S**** S******* |
| Authorizer Title | Director - Gas Operations |
| Authorizer Telephone | 704-810-3230 |
| Authorizer Email | S*************@d*************.com |
| Narrative | On august 24th, 2022, at approximately 1:00 pm, dominion energy north carolina (denc) responded to a ruptured gas main near the intersection of I-40 and rock quarry road, in raleigh, nc. When the denc first responder arrived, emergency responders had already taken control of the area. The third-party excavator, a subcontractor of the company doing work on the interstate, had pierced the 12-in steel, distribution pressure main while installing sound barrier panels along the interstate row. The excavator did not have a locate ticket. The contractor did call in a locate request after the main had been damaged. The leak was stopped by installing stopper fittings at approximately 12:30 am. Gas blew for approximately 12 hours. Denc management decided to make a PHMSA notification due to the concern that our repair costs would exceed $129,300 and that this event would be considered significant in nature. Repairs have been completed and the line is back in service. |
External Resources