Incident details
Operator, cause, commodity and consequences with raw source fields.
GD incident on 2022-05-13 — WV
Operator
Mountaineer Gas Co
Cause
Miscellaneous Root Causes
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities
1 injury
Property damage (nominal)
$600
Incident datetime
2022-05-13 14:10
Report number
Location
WV, RALEIGH
Narrative
Beckley water company were making a water leak repair and called in an emergency one-call ticket. They did not wait for underground utilities to be located before digging and punctured mountaineer gas company's 2" plastic natural gas distribution pipeline operating near 30 psig. Beckley water company notified mountaineer gas company's dispatch center. Mountaineer employees were dispatched to the scene. While installing a full circle band clamp, two of them were overcome with gas and removed from the leak area by personnel onsite. Mountaineer notified 911 and emergency medical personnel responded to the scene to provide medical treatment. One employee was taken to the hospital in an ambulance and the other was taken to the hospital by another employee. Both employees were given a medical assessment at the hospital, one was admitted to inpatient hospitalization for observation, and the other was released.
Detailed record list
Occurred At
2022-05-13 14:10:00
Year
2022
Report Received Date
2022-06-10 00:00:00
Iyear
2022.0
Report Number
20220039.0
Supplemental Number
36740.0
Report Type
Original Final
Operator Id
12878
Name
Mountaineer Gas Co
Operator Street Address
501 56th St. Se
Operator City Name
Charleston
Operator State Abbreviation
WV
Operator Postal Code
25304
Local Datetime
2022-05-13 20:10:00
Time Zone
Eastern
Daylight Savings Ind
Yes
Location Street Address
611 Whitestick St.
Location City Name
Mabscott
Location County Name
Raleigh
Location State Abbreviation
WV
Location Postal Code
25871
Location Latitude
37.77576
Location Longitude
-81.21213
Flow Cont Other Ind
Yes
Flow Cont Other Detail
Full-Circle Band Leak Clamp
Nrc Rpt Datetime
2022-05-13 20:13:00
Nrc Rpt Num
1335962
Additional Nrc Report Numbers
1336073
Commodity Released Type
Natural Gas
Unintentional Release
14.887
Intentional Release
0.0
Fatality Ind
No
Fatal
0
Injury Ind
Yes
Num Emp Injuries
1
Num Contr Injuries
0
Num Er Injuries
0
Num Worker Injuries
0
Num Gp Injuries
0
Injure
1
Ignite Ind
No
Num Pub Evacuated
0.0
Incident Identified Datetime
2022-05-13 14:10:00
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Initial Responder Com Datetime
2022-05-13 14:50:00
On Site Datetime
2022-05-13 14:10:00
Federal
No
Location Type
Public Property
Incident Area Type
Underground
Incident Area Subtype
Exposed Due To Excavation
Depth Of Cover
24.0
Other Underground Facilities
No
Crossing
No
Pipe Facility Type
Privately Owned
System Part Involved
Main
Installation Year
1972.0
Pipe Diameter
2.0
Pipe Specification
Unknown
Pipe Manufacturer
Aldyl-A
Material Involved
Plastic
Plastic Type
Polyethylene (Pe)
Plastic Sdr
11
Material Pe Pipe Code
2406
Release Type
Mechanical Puncture
Puncture Axial
1.0
Puncture Circum
1.0
Class Location Type
Class 2 Location
Est Cost Oper Paid
0.0
Est Cost Prop Damage
600.0
Est Cost Emergency
500.0
Est Cost Other
0.0
Gas Cost In Mcf
6.739
Est Cost Unintentional Release
100.0
Est Cost Intentional Release
0.0
Prpty
1200.0
Commercial Affected
0.0
Industrial Affected
0.0
Residences Affected
0.0
Num Persons Hosp Not Ovnght
1.0
Num Injured Treated By Emt
2.0
Num Resident Building Affctd
0.0
Num Business Building Affctd
0.0
Accident Psig
30.0
Normal Psig
30.0
Mop Psig
40.0
Mop Cfr Section
192.619(A)(4)
Maop Established Date
2016-08-24 00:00:00
Accident Pressure
Pressure Did Not Exceed Maop
Gas Odorized System Type
By-Pass
Gas Odorized Lvl Not Msrd Ind
Yes
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Accident Identifier
Notification From Third Party That Caused The Incident
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
The puncture didn't reduce system pressure enough to cause an alarm at gas control.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Excavation Damage
Cause Details
Excavation Damage By Third Party
Ex Party Type
Excavation Damage By Third Party
Prior Notification Ind
Yes
One Call System Ind
Yes
State Law Exempt Ind
No
Notify Cga Dirt
No
Public Row Ind
Yes
Public Subtype
City Street
Excavator Type
Municipality
Excavator Equipment
Backhoe/trackhoe
Work Performed
Water
One Call Notified Ind
Yes
One Call Ticket Num
2213316772
Locator Type
Facility Owner
Visible Marks
No
Service Interruption
No
Root Cause Category
Miscellaneous Root Causes
Root Cause Type
Root Cause Not Listed (Comment Required)
Root Cause Type Other
Emergency 1 Call Ticket But Did Not Wait For Marks
Preparer Name
P***** K******
Preparer Title
Manager Engineering And Compliance
Preparer Email
P************@m****.com
Preparer Telephone
3043892714
Preparer Fax
3049259605
Local Contact Name
J*** L*****
Local Contact Email
J*********@m****.com
Local Contact Telephone
3046674669
Authorizer Name
T***** W*******
Authorizer Title
Vice President Gas Supply And Technical Services
Authorizer Telephone
3045395740
Authorizer Email
T*************@m****.com
Narrative
Beckley water company were making a water leak repair and called in an emergency one-call ticket. They did not wait for underground utilities to be located before digging and punctured mountaineer gas company's 2" plastic natural gas distribution pipeline operating near 30 psig. Beckley water company notified mountaineer gas company's dispatch center. Mountaineer employees were dispatched to the scene. While installing a full circle band clamp, two of them were overcome with gas and removed from the leak area by personnel onsite. Mountaineer notified 911 and emergency medical personnel responded to the scene to provide medical treatment. One employee was taken to the hospital in an ambulance and the other was taken to the hospital by another employee. Both employees were given a medical assessment at the hospital, one was admitted to inpatient hospitalization for observation, and the other was released.
| Occurred At | 2022-05-13 14:10:00 |
|---|---|
| Year | 2022 |
| Report Received Date | 2022-06-10 00:00:00 |
| Iyear | 2022.0 |
| Report Number | 20220039.0 |
| Supplemental Number | 36740.0 |
| Report Type | Original Final |
| Operator Id | 12878 PHMSA Enforcement |
| Name | Mountaineer Gas Co |
| Operator Street Address | 501 56th St. Se |
| Operator City Name | Charleston |
| Operator State Abbreviation | WV |
| Operator Postal Code | 25304 |
| Local Datetime | 2022-05-13 20:10:00 |
| Time Zone | Eastern |
| Daylight Savings Ind | Yes |
| Location Street Address | 611 Whitestick St. |
| Location City Name | Mabscott |
| Location County Name | Raleigh |
| Location State Abbreviation | WV |
| Location Postal Code | 25871 |
| Location Latitude | 37.77576 Google Maps OpenStreetMap |
| Location Longitude | -81.21213 Google Maps OpenStreetMap |
| Flow Cont Other Ind | Yes |
| Flow Cont Other Detail | Full-Circle Band Leak Clamp |
| Nrc Rpt Datetime | 2022-05-13 20:13:00 |
| Nrc Rpt Num | 1335962 NRC Report How to search |
| Additional Nrc Report Numbers | 1336073 |
| Commodity Released Type | Natural Gas |
| Unintentional Release | 14.887 |
| Intentional Release | 0.0 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | Yes |
| Num Emp Injuries | 1 |
| Num Contr Injuries | 0 |
| Num Er Injuries | 0 |
| Num Worker Injuries | 0 |
| Num Gp Injuries | 0 |
| Injure | 1 |
| Ignite Ind | No |
| Num Pub Evacuated | 0.0 |
| Incident Identified Datetime | 2022-05-13 14:10:00 |
| Communication State Fed Ind | Yes |
| Party Initiated Communication | Operator |
| Initial Responder Com Datetime | 2022-05-13 14:50:00 |
| On Site Datetime | 2022-05-13 14:10:00 |
| Federal | No |
| Location Type | Public Property |
| Incident Area Type | Underground |
| Incident Area Subtype | Exposed Due To Excavation |
| Depth Of Cover | 24.0 |
| Other Underground Facilities | No |
| Crossing | No |
| Pipe Facility Type | Privately Owned |
| System Part Involved | Main |
| Installation Year | 1972.0 |
| Pipe Diameter | 2.0 |
| Pipe Specification | Unknown |
| Pipe Manufacturer | Aldyl-A |
| Material Involved | Plastic |
| Plastic Type | Polyethylene (Pe) |
| Plastic Sdr | 11 |
| Material Pe Pipe Code | 2406 |
| Release Type | Mechanical Puncture |
| Puncture Axial | 1.0 |
| Puncture Circum | 1.0 |
| Class Location Type | Class 2 Location |
| Est Cost Oper Paid | 0.0 |
| Est Cost Prop Damage | 600.0 |
| Est Cost Emergency | 500.0 |
| Est Cost Other | 0.0 |
| Gas Cost In Mcf | 6.739 |
| Est Cost Unintentional Release | 100.0 |
| Est Cost Intentional Release | 0.0 |
| Prpty | 1200.0 |
| Commercial Affected | 0.0 |
| Industrial Affected | 0.0 |
| Residences Affected | 0.0 |
| Num Persons Hosp Not Ovnght | 1.0 |
| Num Injured Treated By Emt | 2.0 |
| Num Resident Building Affctd | 0.0 |
| Num Business Building Affctd | 0.0 |
| Accident Psig | 30.0 |
| Normal Psig | 30.0 |
| Mop Psig | 40.0 |
| Mop Cfr Section | 192.619(A)(4) View CFR 49 §192 |
| Maop Established Date | 2016-08-24 00:00:00 |
| Accident Pressure | Pressure Did Not Exceed Maop |
| Gas Odorized System Type | By-Pass |
| Gas Odorized Lvl Not Msrd Ind | Yes |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | No |
| Accident Identifier | Notification From Third Party That Caused The Incident |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | The puncture didn't reduce system pressure enough to cause an alarm at gas control. |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Excavation Damage |
| Cause Details | Excavation Damage By Third Party |
| Ex Party Type | Excavation Damage By Third Party |
| Prior Notification Ind | Yes |
| One Call System Ind | Yes |
| State Law Exempt Ind | No |
| Notify Cga Dirt | No |
| Public Row Ind | Yes |
| Public Subtype | City Street |
| Excavator Type | Municipality |
| Excavator Equipment | Backhoe/trackhoe |
| Work Performed | Water |
| One Call Notified Ind | Yes |
| One Call Ticket Num | 2213316772 |
| Locator Type | Facility Owner |
| Visible Marks | No |
| Service Interruption | No |
| Root Cause Category | Miscellaneous Root Causes |
| Root Cause Type | Root Cause Not Listed (Comment Required) |
| Root Cause Type Other | Emergency 1 Call Ticket But Did Not Wait For Marks |
| Preparer Name | P***** K****** |
| Preparer Title | Manager Engineering And Compliance |
| Preparer Email | P************@m****.com |
| Preparer Telephone | 3043892714 |
| Preparer Fax | 3049259605 |
| Local Contact Name | J*** L***** |
| Local Contact Email | J*********@m****.com |
| Local Contact Telephone | 3046674669 |
| Authorizer Name | T***** W******* |
| Authorizer Title | Vice President Gas Supply And Technical Services |
| Authorizer Telephone | 3045395740 |
| Authorizer Email | T*************@m****.com |
| Narrative | Beckley water company were making a water leak repair and called in an emergency one-call ticket. They did not wait for underground utilities to be located before digging and punctured mountaineer gas company's 2" plastic natural gas distribution pipeline operating near 30 psig. Beckley water company notified mountaineer gas company's dispatch center. Mountaineer employees were dispatched to the scene. While installing a full circle band clamp, two of them were overcome with gas and removed from the leak area by personnel onsite. Mountaineer notified 911 and emergency medical personnel responded to the scene to provide medical treatment. One employee was taken to the hospital in an ambulance and the other was taken to the hospital by another employee. Both employees were given a medical assessment at the hospital, one was admitted to inpatient hospitalization for observation, and the other was released. |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company