GD incident on 2022-02-23 — OH

Operator
National Gas & Oil Corp
Cause
Natural Force Damage
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$0
Incident datetime
2022-02-23 14:10
Report number
Location
OH, LICKING
Narrative
On wednesday, february 23, 2022, a homeowner reported an explosion and called 911. National gas & oil cooperative was notified approximately 10 minutes later. When cooperative employees arrived at the scene, the service line curb valve was shut and the fire department extinguished the flames. Readings indicated that natural gas was present in the ground around the homeowner's natural gas riser. The homeowner's natural gas service line was tested and leakage was found at the riser head. On tuesday, march 22, 2022 after all insurance parties and fire and explosion investigators could be present, the homeowner's riser was removed and the service line capped at the base of the riser and retested. The service line held the pressure test without the riser. The homeowner's riser was removed and sent to an independent laboratory planned for further investigation (planned for april 21, 2022). This riser was installed by the homeowner or the homeowner's contractor or representative, not by the national gas & oil cooperative. The root cause of the explosion was due to a pulled riser. A tree root approximately 6 feet away from the bend in the riser grew across the service line. Over time, the root pulled the service line most of the way out of the riser connection, causing a leak. The house at 811 blacks rd se has been tore down due to the damages caused by the explosion. The public utilities commission of ohio has completed their investigation and we, national gas and oil cooperative, are waiting on a copy of their report as of 7/19/2022.
Detailed record list
Occurred At
2022-02-23 14:10:00
Year
2022
Report Received Date
2022-04-06 00:00:00
Iyear
2022.0
Report Number
20220027.0
Supplemental Number
36876.0
Report Type
Supplemental Final
Operator Id
Name
National Gas & Oil Corp
Operator Street Address
1500 Granville Road
Operator City Name
Newark
Operator State Abbreviation
OH
Operator Postal Code
43055
Local Datetime
2022-02-23 15:22:00
Time Zone
Eastern
Daylight Savings Ind
Yes
Location Street Address
811 Blacks Rd Se
Location City Name
Hebron
Location County Name
Licking
Location State Abbreviation
OH
Location Postal Code
43025
Location Latitude
Location Longitude
Flow Cont Service Valve Ind
Yes
Flow Cont Meter Reg Ind
Yes
Nrc Rpt Datetime
2022-02-23 15:22:00
Nrc Rpt Num
Commodity Released Type
Natural Gas
Unintentional Release
7.0
Intentional Release
0.0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Ignite Ind
Yes
Ignite Datetime
2022-02-23 13:45:00
How Extinguished
Local/state/federal Emergency Responder
Gas Consumed By Fire In Mcf
7
Explode Ind
Yes
Num Pub Evacuated
1.0
Incident Identified Datetime
2022-02-23 14:10:00
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Initial Responder Com Datetime
2022-02-23 13:51:00
On Site Datetime
2022-02-23 14:17:00
Federal
No
Location Type
Private Property
Incident Area Type
Aboveground
Incident Area Subtype
Inside A Building
Crossing
No
Pipe Facility Type
Cooperative
System Part Involved
Service Riser
Installation Year
1998.0
Customer Type
Single Family Residential
Was Efv Installed Before Ind
No
Curb Valve Inst Before Inc Ind
Yes
Material Involved
Plastic
Plastic Type
Polyethylene (Pe)
Wt Plastic Unknown Ind
Unknown
Material Pe Pipe Code
2406
Release Type
Leak
Leak Type
Connection Failure
Class Location Type
Class 1 Location
Est Cost Oper Paid
277236.0
Est Cost Prop Damage
0.0
Est Cost Emergency
5000.0
Est Cost Other
0.0
Gas Cost In Mcf
39.0
Est Cost Unintentional Release
273.0
Est Cost Intentional Release
0.0
Prpty
282509.0
Commercial Affected
0.0
Industrial Affected
0.0
Residences Affected
1.0
Num Persons Hosp Not Ovnght
1.0
Num Injured Treated By Emt
0.0
Num Resident Building Affctd
1.0
Num Business Building Affctd
0.0
Accident Psig
44.0
Normal Psig
44.0
Mop Psig
60.0
Mop Cfr Section
192.619(A)(1)
Maop Established Date
1998-04-24 00:00:00
Accident Pressure
Pressure Did Not Exceed Maop
Gas Odorized System Type
Odorized By Others
Gas Odorized Level
7
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Accident Identifier
Notification From Public
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
A small leak of this kind was not detectable on such a large system that is monitored by scada.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Natural Force Damage
Cause Details
Trees/vegetation Roots
Natural Force Type
Trees/vegetation Roots
Nf Extreme Weather Ind
No
Nf Vegitation Root Ind
Yes
Preparer Name
C********** S*****
Preparer Title
Compliance Engineer
Preparer Email
C******@t************.com
Preparer Telephone
740-348-1203
Preparer Fax
740-348-1131
Authorizer Name
C********** S*****
Authorizer Title
Compliance Engineer
Authorizer Telephone
740-348-1203
Authorizer Email
C******@t************.com
Narrative
On wednesday, february 23, 2022, a homeowner reported an explosion and called 911. National gas & oil cooperative was notified approximately 10 minutes later. When cooperative employees arrived at the scene, the service line curb valve was shut and the fire department extinguished the flames. Readings indicated that natural gas was present in the ground around the homeowner's natural gas riser. The homeowner's natural gas service line was tested and leakage was found at the riser head. On tuesday, march 22, 2022 after all insurance parties and fire and explosion investigators could be present, the homeowner's riser was removed and the service line capped at the base of the riser and retested. The service line held the pressure test without the riser. The homeowner's riser was removed and sent to an independent laboratory planned for further investigation (planned for april 21, 2022). This riser was installed by the homeowner or the homeowner's contractor or representative, not by the national gas & oil cooperative. The root cause of the explosion was due to a pulled riser. A tree root approximately 6 feet away from the bend in the riser grew across the service line. Over time, the root pulled the service line most of the way out of the riser connection, causing a leak. The house at 811 blacks rd se has been tore down due to the damages caused by the explosion. The public utilities commission of ohio has completed their investigation and we, national gas and oil cooperative, are waiting on a copy of their report as of 7/19/2022.
Occurred At 2022-02-23 14:10:00
Year 2022
Report Received Date 2022-04-06 00:00:00
Iyear 2022.0
Report Number 20220027.0
Supplemental Number 36876.0
Report Type Supplemental Final
Operator Id 13302 PHMSA Enforcement
Name National Gas & Oil Corp
Operator Street Address 1500 Granville Road
Operator City Name Newark
Operator State Abbreviation OH
Operator Postal Code 43055
Local Datetime 2022-02-23 15:22:00
Time Zone Eastern
Daylight Savings Ind Yes
Location Street Address 811 Blacks Rd Se
Location City Name Hebron
Location County Name Licking
Location State Abbreviation OH
Location Postal Code 43025
Location Latitude 39.98781 Google Maps OpenStreetMap
Location Longitude -82.52051 Google Maps OpenStreetMap
Flow Cont Service Valve Ind Yes
Flow Cont Meter Reg Ind Yes
Nrc Rpt Datetime 2022-02-23 15:22:00
Nrc Rpt Num 1329557 NRC Report How to search
Commodity Released Type Natural Gas
Unintentional Release 7.0
Intentional Release 0.0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Ignite Ind Yes
Ignite Datetime 2022-02-23 13:45:00
How Extinguished Local/state/federal Emergency Responder
Gas Consumed By Fire In Mcf 7
Explode Ind Yes
Num Pub Evacuated 1.0
Incident Identified Datetime 2022-02-23 14:10:00
Communication State Fed Ind Yes
Party Initiated Communication Operator
Initial Responder Com Datetime 2022-02-23 13:51:00
On Site Datetime 2022-02-23 14:17:00
Federal No
Location Type Private Property
Incident Area Type Aboveground
Incident Area Subtype Inside A Building
Crossing No
Pipe Facility Type Cooperative
System Part Involved Service Riser
Installation Year 1998.0
Customer Type Single Family Residential
Was Efv Installed Before Ind No
Curb Valve Inst Before Inc Ind Yes
Material Involved Plastic
Plastic Type Polyethylene (Pe)
Wt Plastic Unknown Ind Unknown
Material Pe Pipe Code 2406
Release Type Leak
Leak Type Connection Failure
Class Location Type Class 1 Location
Est Cost Oper Paid 277236.0
Est Cost Prop Damage 0.0
Est Cost Emergency 5000.0
Est Cost Other 0.0
Gas Cost In Mcf 39.0
Est Cost Unintentional Release 273.0
Est Cost Intentional Release 0.0
Prpty 282509.0
Commercial Affected 0.0
Industrial Affected 0.0
Residences Affected 1.0
Num Persons Hosp Not Ovnght 1.0
Num Injured Treated By Emt 0.0
Num Resident Building Affctd 1.0
Num Business Building Affctd 0.0
Accident Psig 44.0
Normal Psig 44.0
Mop Psig 60.0
Mop Cfr Section 192.619(A)(1) View CFR 49 §192
Maop Established Date 1998-04-24 00:00:00
Accident Pressure Pressure Did Not Exceed Maop
Gas Odorized System Type Odorized By Others
Gas Odorized Level 7
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Accident Identifier Notification From Public
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details A small leak of this kind was not detectable on such a large system that is monitored by scada.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Natural Force Damage
Cause Details Trees/vegetation Roots
Natural Force Type Trees/vegetation Roots
Nf Extreme Weather Ind No
Nf Vegitation Root Ind Yes
Preparer Name C********** S*****
Preparer Title Compliance Engineer
Preparer Email C******@t************.com
Preparer Telephone 740-348-1203
Preparer Fax 740-348-1131
Authorizer Name C********** S*****
Authorizer Title Compliance Engineer
Authorizer Telephone 740-348-1203
Authorizer Email C******@t************.com
Narrative On wednesday, february 23, 2022, a homeowner reported an explosion and called 911. National gas & oil cooperative was notified approximately 10 minutes later. When cooperative employees arrived at the scene, the service line curb valve was shut and the fire department extinguished the flames. Readings indicated that natural gas was present in the ground around the homeowner's natural gas riser. The homeowner's natural gas service line was tested and leakage was found at the riser head. On tuesday, march 22, 2022 after all insurance parties and fire and explosion investigators could be present, the homeowner's riser was removed and the service line capped at the base of the riser and retested. The service line held the pressure test without the riser. The homeowner's riser was removed and sent to an independent laboratory planned for further investigation (planned for april 21, 2022). This riser was installed by the homeowner or the homeowner's contractor or representative, not by the national gas & oil cooperative. The root cause of the explosion was due to a pulled riser. A tree root approximately 6 feet away from the bend in the riser grew across the service line. Over time, the root pulled the service line most of the way out of the riser connection, causing a leak. The house at 811 blacks rd se has been tore down due to the damages caused by the explosion. The public utilities commission of ohio has completed their investigation and we, national gas and oil cooperative, are waiting on a copy of their report as of 7/19/2022.