GTG incident on 2022-01-31 — TX

Operator
Columbia Gas Transmission, Llc
Cause
Equipment Failure
Commodity
Natural Gas
Program
GTG
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$460,000
Incident datetime
2022-01-31 17:51
Report number
Location
TX
Narrative
On january 31st, 2022, brinker compressor station (cs) experienced an unintentional release of natural gas (material) into atmosphere. Brinker is a transmission cs that is operated and maintained by columbia gas transmission, llc (company), a tc energy entity. Brinker cs is located in columbiana county, ohio. At 17:45 est, a company employee received a notification from the public of a fire at brinker cs. Company operations personnel arrived on-site at 18:00 est and the fire on the dehydration unit was confirmed. After an initial assessment of the situation and taking all safety precautions, personnel isolated the fuel gas supply to the dehydration system at 18:35 est and the fire was extinguished. The preliminary material loss calculation was determined to be 44 mcf. On february 4, 2022, after the damage caused by the fire was fully evaluated and assessed, it was determined that the cost of repairs may exceed $122,000 so the event was promptly reported to the national response center (nrc). An investigation team was formed to determine the probable cause of the fire on the dehydration unit. The initial nrc report no.1328093 and the nrc 48-hour report no.1328149 have been received on february 4th and february 5th respectively. An investigation was completed, and the following casual factors (cf) were identified: 1- internal mesh of the contractor prevented wet glycol return valve for closing. 2- due to the glycol flooding the reboiler and surge tank, gas pressure did not reach pressure safety valve (psv)-100 that was located on reboiler, therefore psv-100 did not activate to release gas pressure. The following recommendations were issued in order to avoid future re-occurrence from taking place at this cs. 1- create preventive maintenance and monitoring plan specifically for the brinker contact tower with increased internal inspection 2- the tower will be replaced. 3- install high level alarm for the reboiler and surge tank that alarms to the station control panel and high-high switch to drain the reboiler the project at brinker cs was completed and dehy was placed into service on december 2, 2022,
Detailed record list
Report Received Date
2022-02-28 00:00:00
Iyear
2022
Report Number
20220021
Supplemental Number
37436
Report Type
Supplemental Final
Operator Id
Name
Columbia Gas Transmission, Llc
Operator Street Address
700 Louisiana St. Suite 700
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2022-02-04 14:20:00
Time Zone
Eastern
Daylight Savings Ind
No
Location Latitude
Location Longitude
Nrc Rpt Num
Nrc Rpt Datetime
2022-02-04 14:50:00
Additional Nrc Report Numbers
1328149
Commodity Released Type
Natural Gas
Unintentional Release
40
Intentional Release
0
Accompanying Liquid
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Status When Identified
Normal Operation, Includes Pauses During Maintenance
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2022-01-31 19:10:00
Restart Datetime
2022-12-02 13:30:00
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Initial Responder Com Datetime
2022-01-01 18:45:00
Ignite Ind
Yes
Ignite Datetime
2022-01-31 17:45:00
How Extinguished
Operator/contractor
Gas Consumed By Fire In Mcf
40
Explode Ind
No
Num Pub Evacuated
0
Incident Identified Datetime
2022-01-31 17:51:00
On Site Datetime
2022-01-31 18:00:00
On Off Shore
Onshore
Onshore State Abbreviation
Oh
Onshore Postal Code
44431
Onshore City Name
Leetonia
Onshore County Name
Columbiana
Designated Location
Not Applicable
Pipe Fac Name
Brinker Compressor Station
Segment Name
Dehydration System
Federal
No
Location Type
Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Interstate
System Part Involved
Onshore Compressor Station Equipment And Piping
Item Involved
Dehydrator/drier/treater/scrubber
Installation Year
Unknown
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Crack
Class Location Type
Class 2 Location
Could Be Hca
No
Pir Radius
65
Heat Damage Ind
No
Non Heat Damage Ind
No
Did Occur In Mca Ind
No
Est Cost Oper Paid
0
Est Cost Unintentional Release
132
Est Cost Intentional Release
0
Est Cost Prop Damage
460000
Est Cost Emergency
1000
Est Cost Other
0
Gas Cost In Mcf
3.3
Prpty
461132
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Wildlife Impact Ind
No
Accident Psig
40
Gas Flow In Pipe In Mcf
1179
Mop Psig
50
Mop Cfr Section
192.619(A)(1)
Maop Established Date
2003-06-01 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Maop
Pressure Restriction Ind
No
Gas Required Odorized Ind
Yes
Gas Odorized Ind
Yes
Pipeline Function
Transmission System
Scada In Place Ind
No
Accident Identifier
Notification From Public
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
The fire was not due to any involvements by gas control personnel.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Equipment Failure
Cause Details
Other Equipment Failure
Eq Failure Type
Other Equipment Failure
Eq Failure Details
Fire On Dehydration Unit
Eq Additional Other Ind
Yes
Eq Additional Other Details
An Investigation Team Was Formed To Determine The Probable Cause Of The Fire
Preparer Name
K***** R****** A*******
Preparer Email
K*************@t*******.com
Preparer Telephone
(304)590-5956
Authorizer Name
P*** S******
Authorizer Telephone
(304)550-4866
Authorizer Email
P***********@t*******.com
Narrative
On january 31st, 2022, brinker compressor station (cs) experienced an unintentional release of natural gas (material) into atmosphere. Brinker is a transmission cs that is operated and maintained by columbia gas transmission, llc (company), a tc energy entity. Brinker cs is located in columbiana county, ohio. At 17:45 est, a company employee received a notification from the public of a fire at brinker cs. Company operations personnel arrived on-site at 18:00 est and the fire on the dehydration unit was confirmed. After an initial assessment of the situation and taking all safety precautions, personnel isolated the fuel gas supply to the dehydration system at 18:35 est and the fire was extinguished. The preliminary material loss calculation was determined to be 44 mcf. On february 4, 2022, after the damage caused by the fire was fully evaluated and assessed, it was determined that the cost of repairs may exceed $122,000 so the event was promptly reported to the national response center (nrc). An investigation team was formed to determine the probable cause of the fire on the dehydration unit. The initial nrc report no.1328093 and the nrc 48-hour report no.1328149 have been received on february 4th and february 5th respectively. An investigation was completed, and the following casual factors (cf) were identified: 1- internal mesh of the contractor prevented wet glycol return valve for closing. 2- due to the glycol flooding the reboiler and surge tank, gas pressure did not reach pressure safety valve (psv)-100 that was located on reboiler, therefore psv-100 did not activate to release gas pressure. The following recommendations were issued in order to avoid future re-occurrence from taking place at this cs. 1- create preventive maintenance and monitoring plan specifically for the brinker contact tower with increased internal inspection 2- the tower will be replaced. 3- install high level alarm for the reboiler and surge tank that alarms to the station control panel and high-high switch to drain the reboiler the project at brinker cs was completed and dehy was placed into service on december 2, 2022,
Report Received Date 2022-02-28 00:00:00
Iyear 2022
Report Number 20220021
Supplemental Number 37436
Report Type Supplemental Final
Operator Id 2616 PHMSA Enforcement
Name Columbia Gas Transmission, Llc
Operator Street Address 700 Louisiana St. Suite 700
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77002
Local Datetime 2022-02-04 14:20:00
Time Zone Eastern
Daylight Savings Ind No
Location Latitude 40.82479 Google Maps OpenStreetMap
Location Longitude -80.75669 Google Maps OpenStreetMap
Nrc Rpt Num 1328093 NRC Report How to search
Nrc Rpt Datetime 2022-02-04 14:50:00
Additional Nrc Report Numbers 1328149
Commodity Released Type Natural Gas
Unintentional Release 40
Intentional Release 0
Accompanying Liquid 0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Status When Identified Normal Operation, Includes Pauses During Maintenance
Shutdown Due Accident Ind Yes
Shutdown Datetime 2022-01-31 19:10:00
Restart Datetime 2022-12-02 13:30:00
Communication State Fed Ind Yes
Party Initiated Communication Operator
Initial Responder Com Datetime 2022-01-01 18:45:00
Ignite Ind Yes
Ignite Datetime 2022-01-31 17:45:00
How Extinguished Operator/contractor
Gas Consumed By Fire In Mcf 40
Explode Ind No
Num Pub Evacuated 0
Incident Identified Datetime 2022-01-31 17:51:00
On Site Datetime 2022-01-31 18:00:00
On Off Shore Onshore
Onshore State Abbreviation Oh
Onshore Postal Code 44431
Onshore City Name Leetonia
Onshore County Name Columbiana
Designated Location Not Applicable
Pipe Fac Name Brinker Compressor Station
Segment Name Dehydration System
Federal No
Location Type Operator-Controlled Property
Incident Area Type Aboveground
Incident Area Subtype Typical Aboveground Facility Piping Or Appurtenance
Crossing No
Pipe Facility Type Interstate
System Part Involved Onshore Compressor Station Equipment And Piping
Item Involved Dehydrator/drier/treater/scrubber
Installation Year Unknown
Manufactured Year Unknown
Material Involved Carbon Steel
Release Type Leak
Leak Type Crack
Class Location Type Class 2 Location
Could Be Hca No
Pir Radius 65
Heat Damage Ind No
Non Heat Damage Ind No
Did Occur In Mca Ind No
Est Cost Oper Paid 0
Est Cost Unintentional Release 132
Est Cost Intentional Release 0
Est Cost Prop Damage 460000
Est Cost Emergency 1000
Est Cost Other 0
Gas Cost In Mcf 3.3
Prpty 461132
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Wildlife Impact Ind No
Accident Psig 40
Gas Flow In Pipe In Mcf 1179
Mop Psig 50
Mop Cfr Section 192.619(A)(1) View CFR 49 §192
Maop Established Date 2003-06-01 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Maop
Pressure Restriction Ind No
Gas Required Odorized Ind Yes
Gas Odorized Ind Yes
Pipeline Function Transmission System
Scada In Place Ind No
Accident Identifier Notification From Public
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details The fire was not due to any involvements by gas control personnel.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Equipment Failure
Cause Details Other Equipment Failure
Eq Failure Type Other Equipment Failure
Eq Failure Details Fire On Dehydration Unit
Eq Additional Other Ind Yes
Eq Additional Other Details An Investigation Team Was Formed To Determine The Probable Cause Of The Fire
Preparer Name K***** R****** A*******
Preparer Email K*************@t*******.com
Preparer Telephone (304)590-5956
Authorizer Name P*** S******
Authorizer Telephone (304)550-4866
Authorizer Email P***********@t*******.com
Narrative On january 31st, 2022, brinker compressor station (cs) experienced an unintentional release of natural gas (material) into atmosphere. Brinker is a transmission cs that is operated and maintained by columbia gas transmission, llc (company), a tc energy entity. Brinker cs is located in columbiana county, ohio. At 17:45 est, a company employee received a notification from the public of a fire at brinker cs. Company operations personnel arrived on-site at 18:00 est and the fire on the dehydration unit was confirmed. After an initial assessment of the situation and taking all safety precautions, personnel isolated the fuel gas supply to the dehydration system at 18:35 est and the fire was extinguished. The preliminary material loss calculation was determined to be 44 mcf. On february 4, 2022, after the damage caused by the fire was fully evaluated and assessed, it was determined that the cost of repairs may exceed $122,000 so the event was promptly reported to the national response center (nrc). An investigation team was formed to determine the probable cause of the fire on the dehydration unit. The initial nrc report no.1328093 and the nrc 48-hour report no.1328149 have been received on february 4th and february 5th respectively. An investigation was completed, and the following casual factors (cf) were identified: 1- internal mesh of the contractor prevented wet glycol return valve for closing. 2- due to the glycol flooding the reboiler and surge tank, gas pressure did not reach pressure safety valve (psv)-100 that was located on reboiler, therefore psv-100 did not activate to release gas pressure. The following recommendations were issued in order to avoid future re-occurrence from taking place at this cs. 1- create preventive maintenance and monitoring plan specifically for the brinker contact tower with increased internal inspection 2- the tower will be replaced. 3- install high level alarm for the reboiler and surge tank that alarms to the station control panel and high-high switch to drain the reboiler the project at brinker cs was completed and dehy was placed into service on december 2, 2022,