Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2021-11-18 — TX
Operator
Alon Usa, Lp
Cause
Equipment Failure
Commodity
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$0
Incident datetime
2021-11-18 09:00
Report number
Location
TX
Narrative
The dfw pipeline was being swept with nitrogen as part of a final abandonment. The pipeline had been reported as purged by the previous operator and had not been operated in 20+ years, but some liquids were encountered. While pushing the pig with nitrogen, it was observed that pressure no longer could be increased once the pigs has passed valve 4. The purge was shutdown, line blocked in and field personnel dispatched to walk the line. The leak was located about 3/4 miles east of block valve no. 4. Upon excavation it was identified that the line had suffered a previous external strike. That damage had been repaired with a skinner type pipe clamp, which was the source of the failure. The clamp utilized is not considered to be an approved repair clamp and was replaced in order to complete the purge. The purge of the line has subsequently been completed and the line abandoned.
Detailed record list
Report Received Date
2021-12-21 00:00:00
Iyear
2021
Report Number
20210351
Supplemental Number
36472
Report Type
Supplemental Final
Operator Id
31443
Name
Alon Usa, Lp
Operator Street Address
200 Refinery Rd
Operator City Name
Big Spring
Operator State Abbreviation
TX
Operator Postal Code
79721
Local Datetime
2021-11-18 09:00:00
Time Zone
Central
Daylight Savings Ind
No
Location Latitude
32.51371
Location Longitude
-99.54695
Commodity Released Type
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype
Mixture Of Refined Products (Transmix Or Other Mixture)
Unintentional Release Bbls
0.23
Recovered Bbls
0.23
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Contractor Working For The Operator
Incident Identified Datetime
2021-11-18 09:00:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Status When Identified
Idle
Communication State Fed Ind
No
On Site Datetime
2021-11-18 09:30:00
Confirmed Discovery Datetime
2021-11-18 09:30:00
Nrc Rpt Num
Nrc Notification Not Required
Ignite Ind
No
Upstream Action Taken
Valve Closure
Upstream Valve Close Datetime
2021-11-18 08:00:00
Upstream Valve Type Ind
Manual
Downstream Action Taken
Valve Closure
Downstream Vlv Close Datetime
2021-11-18 08:00:00
Downstream Valve Type Ind
Manual
Notify Qualified Indiv Ind
No
Oil Spill Removal Org Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Dfw Pipeline
Segment Name
Abilene To Mingus
Onshore State Abbreviation
Tx
Onshore Postal Code
79601
Onshore City Name
Not Within A Municipality
Onshore County Name
Callahan
Designated Location
Milepost
Designated Name
Mp 20
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
24
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Repair Sleeve Or Clamp
Installation Year
Unknown
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Connection Failure
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
0
Est Cost Prop Damage
0
Est Cost Emergency
10000
Est Cost Environmental
10000
Est Cost Other
0
Prpty
20000
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
175
Mop Psig
1440
Mop Cfr Section
Component Design Pressure �195.406(A)(2)
Maop Established Date
1986-01-01 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
54120
Internal Inspection Ind
Yes
Operation Complications Ind
Yes
Low Flow Ind
Yes
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
No
Cpm In Place Ind
No
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the accident
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Equipment Failure
Cause Details
Failure Of Equipment Body (Except Pump), Tank Plate, Or Other Material
Eq Failure Type
Failure Of Equipment Body (Except Pump), Tank Plate, Or Other Material
Eq Additional Other Ind
Yes
Eq Additional Other Details
Wrong Equipment Installed. Style Of Clamp Not Considered Suitable For Service.
Io Wrong Equipment Ind
Yes
Preparer Name
M****** S******
Preparer Title
Director Row Management And Reg Compliance
Preparer Email
M**************@d*************.com
Preparer Telephone
6306498016
Prepared Date
2022-03-17 00:00:00
Local Contact Name
M****** S******
Local Contact Email
M**************@d*************.com
Local Contact Telephone
6306498016
Authorizer Name
M****** S******
Authorizer Telephone
6306498016
Authorizer Title
Director Row Management And Reg Compliance
Authorizer Email
M**************@d*************.com
Narrative
The dfw pipeline was being swept with nitrogen as part of a final abandonment. The pipeline had been reported as purged by the previous operator and had not been operated in 20+ years, but some liquids were encountered. While pushing the pig with nitrogen, it was observed that pressure no longer could be increased once the pigs has passed valve 4. The purge was shutdown, line blocked in and field personnel dispatched to walk the line. The leak was located about 3/4 miles east of block valve no. 4. Upon excavation it was identified that the line had suffered a previous external strike. That damage had been repaired with a skinner type pipe clamp, which was the source of the failure. The clamp utilized is not considered to be an approved repair clamp and was replaced in order to complete the purge. The purge of the line has subsequently been completed and the line abandoned.
| Report Received Date | 2021-12-21 00:00:00 |
|---|---|
| Iyear | 2021 |
| Report Number | 20210351 |
| Supplemental Number | 36472 |
| Report Type | Supplemental Final |
| Operator Id | 31443 PHMSA Enforcement |
| Name | Alon Usa, Lp |
| Operator Street Address | 200 Refinery Rd |
| Operator City Name | Big Spring |
| Operator State Abbreviation | TX |
| Operator Postal Code | 79721 |
| Local Datetime | 2021-11-18 09:00:00 |
| Time Zone | Central |
| Daylight Savings Ind | No |
| Location Latitude | 32.51371 Google Maps OpenStreetMap |
| Location Longitude | -99.54695 Google Maps OpenStreetMap |
| Commodity Released Type | Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions |
| Commodity Subtype | Mixture Of Refined Products (Transmix Or Other Mixture) |
| Unintentional Release Bbls | 0.23 |
| Recovered Bbls | 0.23 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Local Operating Personnel, Including Contractors |
| Operator Type | Contractor Working For The Operator |
| Incident Identified Datetime | 2021-11-18 09:00:00 |
| System Part Involved | Onshore Pipeline, Including Valve Sites |
| On Off Shore | Onshore |
| Status When Identified | Idle |
| Communication State Fed Ind | No |
| On Site Datetime | 2021-11-18 09:30:00 |
| Confirmed Discovery Datetime | 2021-11-18 09:30:00 |
| Nrc Rpt Num | Nrc Notification Not Required NRC Report How to search |
| Ignite Ind | No |
| Upstream Action Taken | Valve Closure |
| Upstream Valve Close Datetime | 2021-11-18 08:00:00 |
| Upstream Valve Type Ind | Manual |
| Downstream Action Taken | Valve Closure |
| Downstream Vlv Close Datetime | 2021-11-18 08:00:00 |
| Downstream Valve Type Ind | Manual |
| Notify Qualified Indiv Ind | No |
| Oil Spill Removal Org Ind | No |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Dfw Pipeline |
| Segment Name | Abilene To Mingus |
| Onshore State Abbreviation | Tx |
| Onshore Postal Code | 79601 |
| Onshore City Name | Not Within A Municipality |
| Onshore County Name | Callahan |
| Designated Location | Milepost |
| Designated Name | Mp 20 |
| Federal | No |
| Location Type | Pipeline Right-Of-Way |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Soil |
| Depth Of Cover | 24 |
| Crossing | No |
| Pipe Facility Type | Intrastate |
| Item Involved | Repair Sleeve Or Clamp |
| Installation Year | Unknown |
| Manufactured Year | Unknown |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Connection Failure |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | No |
| Remediation Ind | No |
| Water Contam Ind | No |
| Could Be Hca | No |
| Commodity Reached Hca | No |
| Est Cost Oper Paid | 0 |
| Est Cost Gas Released | 0 |
| Est Cost Prop Damage | 0 |
| Est Cost Emergency | 10000 |
| Est Cost Environmental | 10000 |
| Est Cost Other | 0 |
| Prpty | 20000 |
| Num Persons Hosp Not Ovnght | 0 |
| Num Injured Treated By Emt | 0 |
| Num Resident Building Affctd | 0 |
| Num Business Building Affctd | 0 |
| Accident Psig | 175 |
| Mop Psig | 1440 |
| Mop Cfr Section | Component Design Pressure �195.406(A)(2) View CFR 49 §192 |
| Maop Established Date | 1986-01-01 00:00:00 |
| Maop Reversal Flow Ind | No |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Length Segment Isolated | 54120 |
| Internal Inspection Ind | Yes |
| Operation Complications Ind | Yes |
| Low Flow Ind | Yes |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | No |
| Cpm In Place Ind | No |
| Investigation Status | No, the facility was not monitored by a controller(s) at the time of the accident |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Equipment Failure |
| Cause Details | Failure Of Equipment Body (Except Pump), Tank Plate, Or Other Material |
| Eq Failure Type | Failure Of Equipment Body (Except Pump), Tank Plate, Or Other Material |
| Eq Additional Other Ind | Yes |
| Eq Additional Other Details | Wrong Equipment Installed. Style Of Clamp Not Considered Suitable For Service. |
| Io Wrong Equipment Ind | Yes |
| Preparer Name | M****** S****** |
| Preparer Title | Director Row Management And Reg Compliance |
| Preparer Email | M**************@d*************.com |
| Preparer Telephone | 6306498016 |
| Prepared Date | 2022-03-17 00:00:00 |
| Local Contact Name | M****** S****** |
| Local Contact Email | M**************@d*************.com |
| Local Contact Telephone | 6306498016 |
| Authorizer Name | M****** S****** |
| Authorizer Telephone | 6306498016 |
| Authorizer Title | Director Row Management And Reg Compliance |
| Authorizer Email | M**************@d*************.com |
| Narrative | The dfw pipeline was being swept with nitrogen as part of a final abandonment. The pipeline had been reported as purged by the previous operator and had not been operated in 20+ years, but some liquids were encountered. While pushing the pig with nitrogen, it was observed that pressure no longer could be increased once the pigs has passed valve 4. The purge was shutdown, line blocked in and field personnel dispatched to walk the line. The leak was located about 3/4 miles east of block valve no. 4. Upon excavation it was identified that the line had suffered a previous external strike. That damage had been repaired with a skinner type pipe clamp, which was the source of the failure. The clamp utilized is not considered to be an approved repair clamp and was replaced in order to complete the purge. The purge of the line has subsequently been completed and the line abandoned. |
External Resources