HL incident on 2021-08-14 — LA

Operator
Cox Operating Llc
Cause
Corrosion Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$608,711
Incident datetime
2021-08-14 09:30
Report number
Location
LA
Narrative
On august 14, 2021 internal corrosion caused a pinhole leak on cox's 6" HL pipeline segment #3495. Operators noticed the the oil tank level had not increased and the pipeline was in production. They had all production shut in and closed the valves on both ends of the pipeline. A helicopter was then utilized to determine that there was a spill in the marsh about 4 miles from the station. The operator then contact the nrc to complete a notification and contacted forefront cox's osro. At 1057 hours: louisiana state police hazmat; mrs. Shannon; made notification of incident and issued report #21-03650. At 1112 hours: cameron parish lepc; operator #796 mr. Logan; made notification of incident, no report # issued. Two additional nrc notifications were made report #1313688 and #1313827 (48-PHMSA update). Based on evaporation modeling, forefront expected 84% of the released 283.8 bbls of condensate (238.392 bbl) to naturally evaporate leaving 45.408 bbls that was recovered by absorbents and from the in situ burn. To repair the line cox operating had certified split-sleeve clamp (sn-6193401) installed on the pipeline. Cox will continue to monitor the corrosion coupon monthly to determine if chemical treatment will be required.
Detailed record list
Report Received Date
2021-09-11 00:00:00
Iyear
2021
Report Number
20210255
Supplemental Number
36444
Report Type
Supplemental Final
Operator Id
Name
Cox Operating Llc
Operator Street Address
1615 Poydras St. Suite 830 New Orleans
Operator City Name
New Orleans
Operator State Abbreviation
LA
Operator Postal Code
70112
Local Datetime
2021-08-14 09:30:00
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
Commodity Released Type
Crude Oil
Unintentional Release Bbls
283.8
Recovered Bbls
45.4
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
Incident Identified Datetime
2021-08-14 09:30:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2021-08-14 09:30:00
Restart Datetime
2021-09-10 06:00:00
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Initial Responder Com Datetime
2021-08-14 09:30:00
On Site Datetime
2021-08-14 12:05:00
Confirmed Discovery Datetime
2021-08-14 15:52:00
Nrc Rpt Datetime
2021-08-14 11:17:00
Nrc Rpt Num
Ignite Ind
No
Upstream Action Taken
Valve Closure
Upstream Valve Close Datetime
2021-08-14 09:30:00
Upstream Valve Type Ind
Manual
Downstream Action Taken
Valve Closure
Downstream Vlv Close Datetime
2021-08-14 09:30:00
Downstream Valve Type Ind
Manual
Notify Qualified Indiv Ind
Yes
Qualified Indiv Notif Datetime
2021-08-14 09:30:00
Oil Spill Removal Org Ind
Yes
Osro Activated Datetime
2021-08-14 10:15:00
Osro Arrived On Site Dt
8/14/2021 12:05
Num Pub Evacuated
0
Pipe Fac Name
Sabine Gas Plant
Segment Name
Wc17 - Sgp Segment # 3495
Onshore State Abbreviation
La
Onshore Postal Code
70631
Onshore City Name
Cameron
Onshore County Name
Cameron
Designated Location
Milepost/valve Station
Designated Name
4mls From Sgp
Federal
No
Location Type
Originated On Operator-Controlled Property, But Then Flowed Or Migrated Off The Property
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
79
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pipe
Pipe Type
Pipe Body
Puddle Weld Ind
No
Pipe Diameter
6
Pipe Wall Thickness
0.28
Pipe Smys
35000
Pipe Specification
Api 5l Gr B
Pipe Seam Type
Erw � Unknown Frequency
Pipe Manufacturer
Republic Steel
Pipe Coating Type
Extruded Polyehylene
Coating Applied Ind
No
Installation Year
1965
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
Yes
Remediation Ind
Yes
Surface Water Remed Ind
Yes
Soil Remed Ind
Yes
Vegetation Remed Ind
Yes
Water Contam Ind
Yes
Surface Contam Ind
Yes
Amount Released
283.8
Rel Water Name
La Marsh In Cameron Parish
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
10000
Est Cost Gas Released
18447
Est Cost Prop Damage
608711
Est Cost Emergency
1256605
Est Cost Environmental
0
Est Cost Other
0
Prpty
1893763
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
60
Mop Psig
400
Mop Cfr Section
Subpart E Pressure Test �195.406(A)(3)
Maop Established Date
2016-01-22 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
55545
Internal Inspection Ind
No
Other Inspection Ind
Yes
Internal Inspection Details
No Pig Launcher Or Receiver.
Operation Complications Ind
Yes
Low Flow Ind
Yes
Pipeline Function
=< 20% Smys Regulated Gathering
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the accident
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
Internal Corrosion
Internal External
Internal Corrosion
Int Visual Exam Results
General Corrosion
Int Corrosive Commodity Ind
Yes
Int Field Exam Basis Ind
Yes
Int Low Point Pipe Loc Ind
Yes
Corrosion Inhibitors
No
Corrosion Lining
No
Cleaning Dewatering
No
Corrosion Coupons
Yes
Collected Data Ind
No
Has Hydrtst Conduc Before Ind
Yes
Hydrtst Most Rcnt Year
2016
Hydrtst Most Rcnt Pressure
500
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
T*** M******
Preparer Title
Pipeline Regulatory
Preparer Email
T*******@c*****.com
Preparer Telephone
985-855-1236
Prepared Date
2022-03-09 00:00:00
Authorizer Name
T*** M******
Authorizer Telephone
985-855-1236
Authorizer Title
Pipeline Regulatory
Authorizer Email
T*******@c*****.com
Narrative
On august 14, 2021 internal corrosion caused a pinhole leak on cox's 6" HL pipeline segment #3495. Operators noticed the the oil tank level had not increased and the pipeline was in production. They had all production shut in and closed the valves on both ends of the pipeline. A helicopter was then utilized to determine that there was a spill in the marsh about 4 miles from the station. The operator then contact the nrc to complete a notification and contacted forefront cox's osro. At 1057 hours: louisiana state police hazmat; mrs. Shannon; made notification of incident and issued report #21-03650. At 1112 hours: cameron parish lepc; operator #796 mr. Logan; made notification of incident, no report # issued. Two additional nrc notifications were made report #1313688 and #1313827 (48-PHMSA update). Based on evaporation modeling, forefront expected 84% of the released 283.8 bbls of condensate (238.392 bbl) to naturally evaporate leaving 45.408 bbls that was recovered by absorbents and from the in situ burn. To repair the line cox operating had certified split-sleeve clamp (sn-6193401) installed on the pipeline. Cox will continue to monitor the corrosion coupon monthly to determine if chemical treatment will be required.
Report Received Date 2021-09-11 00:00:00
Iyear 2021
Report Number 20210255
Supplemental Number 36444
Report Type Supplemental Final
Operator Id 39498 PHMSA Enforcement
Name Cox Operating Llc
Operator Street Address 1615 Poydras St. Suite 830 New Orleans
Operator City Name New Orleans
Operator State Abbreviation LA
Operator Postal Code 70112
Local Datetime 2021-08-14 09:30:00
Time Zone Central
Daylight Savings Ind Yes
Location Latitude 29.7375 Google Maps OpenStreetMap
Location Longitude -93.823194 Google Maps OpenStreetMap
Commodity Released Type Crude Oil
Unintentional Release Bbls 283.8
Recovered Bbls 45.4
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Local Operating Personnel, Including Contractors
Operator Type Operator Employee
Incident Identified Datetime 2021-08-14 09:30:00
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Status When Identified Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind Yes
Shutdown Datetime 2021-08-14 09:30:00
Restart Datetime 2021-09-10 06:00:00
Communication State Fed Ind Yes
Party Initiated Communication Operator
Initial Responder Com Datetime 2021-08-14 09:30:00
On Site Datetime 2021-08-14 12:05:00
Confirmed Discovery Datetime 2021-08-14 15:52:00
Nrc Rpt Datetime 2021-08-14 11:17:00
Nrc Rpt Num 1313674 NRC Report How to search
Ignite Ind No
Upstream Action Taken Valve Closure
Upstream Valve Close Datetime 2021-08-14 09:30:00
Upstream Valve Type Ind Manual
Downstream Action Taken Valve Closure
Downstream Vlv Close Datetime 2021-08-14 09:30:00
Downstream Valve Type Ind Manual
Notify Qualified Indiv Ind Yes
Qualified Indiv Notif Datetime 2021-08-14 09:30:00
Oil Spill Removal Org Ind Yes
Osro Activated Datetime 2021-08-14 10:15:00
Osro Arrived On Site Dt 8/14/2021 12:05
Num Pub Evacuated 0
Pipe Fac Name Sabine Gas Plant
Segment Name Wc17 - Sgp Segment # 3495
Onshore State Abbreviation La
Onshore Postal Code 70631
Onshore City Name Cameron
Onshore County Name Cameron
Designated Location Milepost/valve Station
Designated Name 4mls From Sgp
Federal No
Location Type Originated On Operator-Controlled Property, But Then Flowed Or Migrated Off The Property
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 79
Crossing No
Pipe Facility Type Interstate
Item Involved Pipe
Pipe Type Pipe Body
Puddle Weld Ind No
Pipe Diameter 6
Pipe Wall Thickness 0.28
Pipe Smys 35000
Pipe Specification Api 5l Gr B
Pipe Seam Type Erw � Unknown Frequency
Pipe Manufacturer Republic Steel
Pipe Coating Type Extruded Polyehylene
Coating Applied Ind No
Installation Year 1965
Manufactured Year Unknown
Material Involved Carbon Steel
Release Type Leak
Leak Type Pinhole
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment Yes
Remediation Ind Yes
Surface Water Remed Ind Yes
Soil Remed Ind Yes
Vegetation Remed Ind Yes
Water Contam Ind Yes
Surface Contam Ind Yes
Amount Released 283.8
Rel Water Name La Marsh In Cameron Parish
Could Be Hca No
Commodity Reached Hca No
Est Cost Oper Paid 10000
Est Cost Gas Released 18447
Est Cost Prop Damage 608711
Est Cost Emergency 1256605
Est Cost Environmental 0
Est Cost Other 0
Prpty 1893763
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Accident Psig 60
Mop Psig 400
Mop Cfr Section Subpart E Pressure Test �195.406(A)(3) View CFR 49 §192
Maop Established Date 2016-01-22 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Length Segment Isolated 55545
Internal Inspection Ind No
Other Inspection Ind Yes
Internal Inspection Details No Pig Launcher Or Receiver.
Operation Complications Ind Yes
Low Flow Ind Yes
Pipeline Function =< 20% Smys Regulated Gathering
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Cpm In Place Ind No
Investigation Status No, the facility was not monitored by a controller(s) at the time of the accident
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Corrosion Failure
Cause Details Internal Corrosion
Internal External Internal Corrosion
Int Visual Exam Results General Corrosion
Int Corrosive Commodity Ind Yes
Int Field Exam Basis Ind Yes
Int Low Point Pipe Loc Ind Yes
Corrosion Inhibitors No
Corrosion Lining No
Cleaning Dewatering No
Corrosion Coupons Yes
Collected Data Ind No
Has Hydrtst Conduc Before Ind Yes
Hydrtst Most Rcnt Year 2016
Hydrtst Most Rcnt Pressure 500
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Preparer Name T*** M******
Preparer Title Pipeline Regulatory
Preparer Email T*******@c*****.com
Preparer Telephone 985-855-1236
Prepared Date 2022-03-09 00:00:00
Authorizer Name T*** M******
Authorizer Telephone 985-855-1236
Authorizer Title Pipeline Regulatory
Authorizer Email T*******@c*****.com
Narrative On august 14, 2021 internal corrosion caused a pinhole leak on cox's 6" HL pipeline segment #3495. Operators noticed the the oil tank level had not increased and the pipeline was in production. They had all production shut in and closed the valves on both ends of the pipeline. A helicopter was then utilized to determine that there was a spill in the marsh about 4 miles from the station. The operator then contact the nrc to complete a notification and contacted forefront cox's osro. At 1057 hours: louisiana state police hazmat; mrs. Shannon; made notification of incident and issued report #21-03650. At 1112 hours: cameron parish lepc; operator #796 mr. Logan; made notification of incident, no report # issued. Two additional nrc notifications were made report #1313688 and #1313827 (48-PHMSA update). Based on evaporation modeling, forefront expected 84% of the released 283.8 bbls of condensate (238.392 bbl) to naturally evaporate leaving 45.408 bbls that was recovered by absorbents and from the in situ burn. To repair the line cox operating had certified split-sleeve clamp (sn-6193401) installed on the pipeline. Cox will continue to monitor the corrosion coupon monthly to determine if chemical treatment will be required.

All rights reserved. Copyright © by ClearPHMSA