HL incident on 2021-06-29 — OK

Operator
Magellan Crude Oil Pipeline Company, L.p.
Cause
Corrosion Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$13,000
Incident datetime
2021-06-29 08:00
Report number
Location
OK
Narrative
At 8:00 am on june 29th, 2021 magellan operations personnel were conducting a daily facility inspection when product was discovered near the crude manifold. The piping was isolated and cleanup activities were initiated. The leak source was determined to be a pin hole on the tank 3503 lateral piping. A temporary clamp was installed and a portion of the lateral piping was uninstalled in order to remove the affected asset from service. A permanent repair is in progress.
Detailed record list
Report Received Date
2021-07-29 00:00:00
Iyear
2021
Report Number
20210217
Supplemental Number
35549
Report Type
Original Final
Operator Id
Name
Magellan Crude Oil Pipeline Company, L.p.
Operator Street Address
100 West 5th Street
Operator City Name
Tulsa
Operator State Abbreviation
OK
Operator Postal Code
74103
Local Datetime
2021-06-29 08:00:00
Location Latitude
Location Longitude
Commodity Released Type
Crude Oil
Unintentional Release Bbls
3
Recovered Bbls
3
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
Incident Identified Datetime
2021-06-29 08:00:00
System Part Involved
Onshore Terminal/tank Farm Equipment And Piping
On Off Shore
Onshore
Shutdown Due Accident Ind
No
Shutdown Explain
The Tank Was Isolated From Mainline Movements.
On Site Datetime
2021-06-29 08:00:00
Nrc Rpt Num
Nrc Notification Not Required
Ignite Ind
No
Explode Ind
No
Num Pub Evacuated
0
Pipe Fac Name
East Houston Terminal
Segment Name
Fac Id 728
Onshore State Abbreviation
Tx
Onshore Postal Code
77029
Onshore City Name
Houston
Onshore County Name
Harris
Designated Location
Milepost/valve Station
Designated Name
0
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pipe
Pipe Type
Pipe Body
Pipe Diameter
36
Pipe Wall Thickness
0.375
Pipe Smys
42000
Pipe Specification
Api 5l X-42, Psl2
Pipe Seam Type
Single Saw
Pipe Manufacturer
Hyundai Steel
Pipe Coating Type
Paint
Installation Year
2016
Manufactured Year
2015
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
No
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
Yes
High Pop Ind
Yes
High Pop Yes No
Yes
Est Cost Oper Paid
0
Est Cost Gas Released
210
Est Cost Prop Damage
13000
Est Cost Emergency
1000
Est Cost Environmental
0
Est Cost Other
0
Prpty
14210
Accident Psig
100
Mop Psig
275
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
The release volume was below detectable thresholds.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
Internal Corrosion
Internal External
Internal Corrosion
Int Visual Exam Results
Localized Pitting
Int Water Acid Ind
Yes
Int Field Exam Basis Ind
Yes
Int Low Point Pipe Loc Ind
Yes
Corrosion Inhibitors
Yes
Corrosion Lining
No
Cleaning Dewatering
Not Applicable - Not Mainline Pipe
Corrosion Coupons
Not Applicable - Not Mainline Pipe
Collected Data Ind
No
Has Hydrtst Conduc Before Ind
No
Direct Asmnt Conducted
No
Non Destructive Exam Ind
Yes
Exm Handl Ultrasonic Rcnt Year
2020
Exm Handl Ultrasonic Rcnt Ind
Yes
Preparer Name
S****** L******
Preparer Title
Asset Integrity Analyst
Preparer Email
S**************@m*********.com
Preparer Telephone
9185747327
Prepared Date
2021-07-29 00:00:00
Authorizer Name
G***** R****
Authorizer Telephone
9185747165
Authorizer Title
Supervisor Of Integrity Management
Authorizer Email
G**********@m*********.com
Narrative
At 8:00 am on june 29th, 2021 magellan operations personnel were conducting a daily facility inspection when product was discovered near the crude manifold. The piping was isolated and cleanup activities were initiated. The leak source was determined to be a pin hole on the tank 3503 lateral piping. A temporary clamp was installed and a portion of the lateral piping was uninstalled in order to remove the affected asset from service. A permanent repair is in progress.
Report Received Date 2021-07-29 00:00:00
Iyear 2021
Report Number 20210217
Supplemental Number 35549
Report Type Original Final
Operator Id 39504 PHMSA Enforcement
Name Magellan Crude Oil Pipeline Company, L.p.
Operator Street Address 100 West 5th Street
Operator City Name Tulsa
Operator State Abbreviation OK
Operator Postal Code 74103
Local Datetime 2021-06-29 08:00:00
Location Latitude 29.793063 Google Maps OpenStreetMap
Location Longitude -95.281275 Google Maps OpenStreetMap
Commodity Released Type Crude Oil
Unintentional Release Bbls 3
Recovered Bbls 3
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Local Operating Personnel, Including Contractors
Operator Type Operator Employee
Incident Identified Datetime 2021-06-29 08:00:00
System Part Involved Onshore Terminal/tank Farm Equipment And Piping
On Off Shore Onshore
Shutdown Due Accident Ind No
Shutdown Explain The Tank Was Isolated From Mainline Movements.
On Site Datetime 2021-06-29 08:00:00
Nrc Rpt Num Nrc Notification Not Required NRC Report How to search
Ignite Ind No
Explode Ind No
Num Pub Evacuated 0
Pipe Fac Name East Houston Terminal
Segment Name Fac Id 728
Onshore State Abbreviation Tx
Onshore Postal Code 77029
Onshore City Name Houston
Onshore County Name Harris
Designated Location Milepost/valve Station
Designated Name 0
Federal No
Location Type Totally Contained On Operator-Controlled Property
Incident Area Type Aboveground
Incident Area Subtype Typical Aboveground Facility Piping Or Appurtenance
Crossing No
Pipe Facility Type Interstate
Item Involved Pipe
Pipe Type Pipe Body
Pipe Diameter 36
Pipe Wall Thickness 0.375
Pipe Smys 42000
Pipe Specification Api 5l X-42, Psl2
Pipe Seam Type Single Saw
Pipe Manufacturer Hyundai Steel
Pipe Coating Type Paint
Installation Year 2016
Manufactured Year 2015
Material Involved Carbon Steel
Release Type Leak
Leak Type Pinhole
Wildlife Impact Ind No
Soil Contamination No
Long Term Assessment No
Remediation Ind No
Water Contam Ind No
Could Be Hca Yes
Commodity Reached Hca Yes
High Pop Ind Yes
High Pop Yes No Yes
Est Cost Oper Paid 0
Est Cost Gas Released 210
Est Cost Prop Damage 13000
Est Cost Emergency 1000
Est Cost Environmental 0
Est Cost Other 0
Prpty 14210
Accident Psig 100
Mop Psig 275
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Cpm In Place Ind No
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details The release volume was below detectable thresholds.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Corrosion Failure
Cause Details Internal Corrosion
Internal External Internal Corrosion
Int Visual Exam Results Localized Pitting
Int Water Acid Ind Yes
Int Field Exam Basis Ind Yes
Int Low Point Pipe Loc Ind Yes
Corrosion Inhibitors Yes
Corrosion Lining No
Cleaning Dewatering Not Applicable - Not Mainline Pipe
Corrosion Coupons Not Applicable - Not Mainline Pipe
Collected Data Ind No
Has Hydrtst Conduc Before Ind No
Direct Asmnt Conducted No
Non Destructive Exam Ind Yes
Exm Handl Ultrasonic Rcnt Year 2020
Exm Handl Ultrasonic Rcnt Ind Yes
Preparer Name S****** L******
Preparer Title Asset Integrity Analyst
Preparer Email S**************@m*********.com
Preparer Telephone 9185747327
Prepared Date 2021-07-29 00:00:00
Authorizer Name G***** R****
Authorizer Telephone 9185747165
Authorizer Title Supervisor Of Integrity Management
Authorizer Email G**********@m*********.com
Narrative At 8:00 am on june 29th, 2021 magellan operations personnel were conducting a daily facility inspection when product was discovered near the crude manifold. The piping was isolated and cleanup activities were initiated. The leak source was determined to be a pin hole on the tank 3503 lateral piping. A temporary clamp was installed and a portion of the lateral piping was uninstalled in order to remove the affected asset from service. A permanent repair is in progress.

All rights reserved. Copyright © by ClearPHMSA