HL incident on 2021-05-18 — NJ
Operator
Torrance Pipeline Company Llc
Cause
Corrosion Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$29,537
Incident datetime
2021-05-18 10:16
Report number
Location
NJ
Narrative
On may 18, 2021, at approximately 1016 hrs. Pdt, a torrance pipeline company (tpc) operator conducting facility rounds arrived at eptc meter station. Upon arrival, the operator discovered crude oil product on the ground inside the facility. The operator immediately contacted his supervisor; tpc supervisor arrived on site at approximately 1033 hrs. Pdt. Cleanup and recovery crew were dispatched to the facility to commence response efforts. Initial estimates approximately 1 barrel of crude oil to soil. Internal and external notifications were promptly made. On may 18, 2021, at 1042 hrs. Pdt, cal oes was notified - control number #21-2652. At approximately 1052 hrs. Pdt, nrc was notified - report #1305340. On may 20, 2021, a 48-hour report to nrc was made - report #1305563; no changes to report at that time. The source of the release, a two-inch thermal relief line with a through wall pinhole at the 6 oclock position was located and secured as ongoing cleanup was performed. The thermal relief line was replaced and permanently repaired. An investigation is underway to determine the cause of the release; a supplemental report will be submitted. ________________________________________________________________________________________________________________________ supplemental / final report updates: updated part d, items 8a-8g updated part g1, ic, items 6-13 updated part h, narrative description of the accident: torrance pipeline company has concluded its investigation and has identified the cause of the release. As initially reported at the 6 oclock position, a through wall pinhole was identified. Based on visual field examination and non-destructive flexoform phased array and conventional ultrasonic evaluation, it has been confirmed to be an isolated internal corrosion pit. Initial mitigative action was to replace the failed two-inch thermal relief line with a new two-inch thermal relief line. Additional mitigative actions include implementation of weekly operator/line rider facility visits and inspections inside all remote meter station sites. Future potential implementations include development of a facility integrity inspection standard in addition to evaluating remote meter/pump stations and prioritizing future facility integrity inspections of deadleg, no flow or low flow piping. This concludes the investigation and actions taken for this incident.
Detailed record list
Report Received Date
2021-06-17 00:00:00
Iyear
2021
Report Number
20210177
Supplemental Number
35811
Report Type
Supplemental Final
Operator Id
39535
Name
Torrance Pipeline Company Llc
Operator Street Address
One Sylvan Way Second Floor
Operator City Name
Parsippany
Operator State Abbreviation
NJ
Operator Postal Code
07054
Local Datetime
2021-05-18 10:33:00
Location Latitude
33.804229
Location Longitude
-118.28371
Commodity Released Type
Crude Oil
Unintentional Release Bbls
1
Recovered Bbls
1
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Ground Patrol By Operator Or Its Contractor
Operator Type
Operator Employee
Incident Identified Datetime
2021-05-18 10:16:00
System Part Involved
Onshore Pump/meter Station Equipment And Piping
On Off Shore
Onshore
Shutdown Due Accident Ind
No
Shutdown Explain
This Lateral Segment Was Not In Operation At The Time Of Discovery
On Site Datetime
2021-05-18 10:16:00
Nrc Rpt Datetime
2021-05-18 10:52:00
Nrc Rpt Num
1305340
Ignite Ind
No
Explode Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Eptc Meter
Segment Name
M-146b Lateral
Onshore State Abbreviation
Ca
Onshore Postal Code
90745
Onshore City Name
Carson
Onshore County Name
Los Angeles
Designated Location
Survey Station No.
Designated Name
0+68
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Relief Line And Relief Equipment
Installation Year
2000
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
Yes
High Pop Ind
Yes
High Pop Yes No
Yes
Usa Drinking Ind
Yes
Usa Drinking Yes No
Yes
Est Cost Oper Paid
0
Est Cost Gas Released
68
Est Cost Prop Damage
29537
Est Cost Emergency
49606
Est Cost Environmental
0
Est Cost Other
0
Est Cost Other Details
Corrected $68 From 8a To 8b.
Prpty
79211
Accident Psig
137
Mop Psig
393
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
The pipeline was down and not shipping when discovery of the release was made.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
Internal Corrosion
Internal External
Internal Corrosion
Int Visual Exam Results
Other
Int Visual Exam Details
Isolated Internal Corrosion Pit
Int Other Corrosion Ind
Yes
Int Corrosion Type Details
Isolated Internal Corrosion Pit
Int Field Exam Basis Ind
Yes
Int Low Point Pipe Loc Ind
Yes
Corrosion Inhibitors
No
Corrosion Lining
No
Cleaning Dewatering
No
Corrosion Coupons
No
Preparer Name
A****** G*****
Preparer Title
Regulatory Compliance Specialist
Preparer Email
A*************@p********.com
Preparer Telephone
310-212-1764
Prepared Date
2021-09-23 00:00:00
Authorizer Name
T***** M*****
Authorizer Telephone
281-602-4424
Authorizer Title
Director Regulatory Compliance
Authorizer Email
T************@p********.com
Narrative
On may 18, 2021, at approximately 1016 hrs. Pdt, a torrance pipeline company (tpc) operator conducting facility rounds arrived at eptc meter station. Upon arrival, the operator discovered crude oil product on the ground inside the facility. The operator immediately contacted his supervisor; tpc supervisor arrived on site at approximately 1033 hrs. Pdt. Cleanup and recovery crew were dispatched to the facility to commence response efforts. Initial estimates approximately 1 barrel of crude oil to soil. Internal and external notifications were promptly made. On may 18, 2021, at 1042 hrs. Pdt, cal oes was notified - control number #21-2652. At approximately 1052 hrs. Pdt, nrc was notified - report #1305340. On may 20, 2021, a 48-hour report to nrc was made - report #1305563; no changes to report at that time. The source of the release, a two-inch thermal relief line with a through wall pinhole at the 6 oclock position was located and secured as ongoing cleanup was performed. The thermal relief line was replaced and permanently repaired. An investigation is underway to determine the cause of the release; a supplemental report will be submitted. ________________________________________________________________________________________________________________________ supplemental / final report updates: updated part d, items 8a-8g updated part g1, ic, items 6-13 updated part h, narrative description of the accident: torrance pipeline company has concluded its investigation and has identified the cause of the release. As initially reported at the 6 oclock position, a through wall pinhole was identified. Based on visual field examination and non-destructive flexoform phased array and conventional ultrasonic evaluation, it has been confirmed to be an isolated internal corrosion pit. Initial mitigative action was to replace the failed two-inch thermal relief line with a new two-inch thermal relief line. Additional mitigative actions include implementation of weekly operator/line rider facility visits and inspections inside all remote meter station sites. Future potential implementations include development of a facility integrity inspection standard in addition to evaluating remote meter/pump stations and prioritizing future facility integrity inspections of deadleg, no flow or low flow piping. This concludes the investigation and actions taken for this incident.
| Report Received Date | 2021-06-17 00:00:00 |
|---|---|
| Iyear | 2021 |
| Report Number | 20210177 |
| Supplemental Number | 35811 |
| Report Type | Supplemental Final |
| Operator Id | 39535 PHMSA Enforcement |
| Name | Torrance Pipeline Company Llc |
| Operator Street Address | One Sylvan Way Second Floor |
| Operator City Name | Parsippany |
| Operator State Abbreviation | NJ |
| Operator Postal Code | 07054 |
| Local Datetime | 2021-05-18 10:33:00 |
| Location Latitude | 33.804229 Google Maps OpenStreetMap |
| Location Longitude | -118.28371 Google Maps OpenStreetMap |
| Commodity Released Type | Crude Oil |
| Unintentional Release Bbls | 1 |
| Recovered Bbls | 1 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Ground Patrol By Operator Or Its Contractor |
| Operator Type | Operator Employee |
| Incident Identified Datetime | 2021-05-18 10:16:00 |
| System Part Involved | Onshore Pump/meter Station Equipment And Piping |
| On Off Shore | Onshore |
| Shutdown Due Accident Ind | No |
| Shutdown Explain | This Lateral Segment Was Not In Operation At The Time Of Discovery |
| On Site Datetime | 2021-05-18 10:16:00 |
| Nrc Rpt Datetime | 2021-05-18 10:52:00 |
| Nrc Rpt Num | 1305340 NRC Report How to search |
| Ignite Ind | No |
| Explode Ind | No |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Eptc Meter |
| Segment Name | M-146b Lateral |
| Onshore State Abbreviation | Ca |
| Onshore Postal Code | 90745 |
| Onshore City Name | Carson |
| Onshore County Name | Los Angeles |
| Designated Location | Survey Station No. |
| Designated Name | 0+68 |
| Federal | No |
| Location Type | Totally Contained On Operator-Controlled Property |
| Incident Area Type | Aboveground |
| Incident Area Subtype | Typical Aboveground Facility Piping Or Appurtenance |
| Crossing | No |
| Pipe Facility Type | Intrastate |
| Item Involved | Relief Line And Relief Equipment |
| Installation Year | 2000 |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Pinhole |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | No |
| Remediation Ind | No |
| Water Contam Ind | No |
| Could Be Hca | Yes |
| Commodity Reached Hca | Yes |
| High Pop Ind | Yes |
| High Pop Yes No | Yes |
| Usa Drinking Ind | Yes |
| Usa Drinking Yes No | Yes |
| Est Cost Oper Paid | 0 |
| Est Cost Gas Released | 68 |
| Est Cost Prop Damage | 29537 |
| Est Cost Emergency | 49606 |
| Est Cost Environmental | 0 |
| Est Cost Other | 0 |
| Est Cost Other Details | Corrected $68 From 8a To 8b. |
| Prpty | 79211 |
| Accident Psig | 137 |
| Mop Psig | 393 |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | No |
| Cpm In Place Ind | No |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | The pipeline was down and not shipping when discovery of the release was made. |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Corrosion Failure |
| Cause Details | Internal Corrosion |
| Internal External | Internal Corrosion |
| Int Visual Exam Results | Other |
| Int Visual Exam Details | Isolated Internal Corrosion Pit |
| Int Other Corrosion Ind | Yes |
| Int Corrosion Type Details | Isolated Internal Corrosion Pit |
| Int Field Exam Basis Ind | Yes |
| Int Low Point Pipe Loc Ind | Yes |
| Corrosion Inhibitors | No |
| Corrosion Lining | No |
| Cleaning Dewatering | No |
| Corrosion Coupons | No |
| Preparer Name | A****** G***** |
| Preparer Title | Regulatory Compliance Specialist |
| Preparer Email | A*************@p********.com |
| Preparer Telephone | 310-212-1764 |
| Prepared Date | 2021-09-23 00:00:00 |
| Authorizer Name | T***** M***** |
| Authorizer Telephone | 281-602-4424 |
| Authorizer Title | Director Regulatory Compliance |
| Authorizer Email | T************@p********.com |
| Narrative | On may 18, 2021, at approximately 1016 hrs. Pdt, a torrance pipeline company (tpc) operator conducting facility rounds arrived at eptc meter station. Upon arrival, the operator discovered crude oil product on the ground inside the facility. The operator immediately contacted his supervisor; tpc supervisor arrived on site at approximately 1033 hrs. Pdt. Cleanup and recovery crew were dispatched to the facility to commence response efforts. Initial estimates approximately 1 barrel of crude oil to soil. Internal and external notifications were promptly made. On may 18, 2021, at 1042 hrs. Pdt, cal oes was notified - control number #21-2652. At approximately 1052 hrs. Pdt, nrc was notified - report #1305340. On may 20, 2021, a 48-hour report to nrc was made - report #1305563; no changes to report at that time. The source of the release, a two-inch thermal relief line with a through wall pinhole at the 6 oclock position was located and secured as ongoing cleanup was performed. The thermal relief line was replaced and permanently repaired. An investigation is underway to determine the cause of the release; a supplemental report will be submitted. ________________________________________________________________________________________________________________________ supplemental / final report updates: updated part d, items 8a-8g updated part g1, ic, items 6-13 updated part h, narrative description of the accident: torrance pipeline company has concluded its investigation and has identified the cause of the release. As initially reported at the 6 oclock position, a through wall pinhole was identified. Based on visual field examination and non-destructive flexoform phased array and conventional ultrasonic evaluation, it has been confirmed to be an isolated internal corrosion pit. Initial mitigative action was to replace the failed two-inch thermal relief line with a new two-inch thermal relief line. Additional mitigative actions include implementation of weekly operator/line rider facility visits and inspections inside all remote meter station sites. Future potential implementations include development of a facility integrity inspection standard in addition to evaluating remote meter/pump stations and prioritizing future facility integrity inspections of deadleg, no flow or low flow piping. This concludes the investigation and actions taken for this incident. |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company
All rights reserved. Copyright © by ClearPHMSA