Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2021-05-11 — MT
Operator
Cenex Pipeline Llc
Cause
Incorrect Operation
Commodity
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$0
Incident datetime
2021-05-11 10:17
Report number
Location
MT
Narrative
During the field portion of a PHMSA integrated inspection on may 11, 2021, block valve 232 was found by cenex pipeline staff and the PHMSA inspector to be dripping a small volume of product from the body bleed valve. Controllers opened a downstream valve to bleed pressure/volume away from the site and oq qualified field staff tightened the bleed within minutes of arriving on-site to stop the leak. No repair was needed beyond tightening the bleed. Release estimate was based on volume of soil cleanup associated with the release. No leak alarms were received because the leak alarm thresholds were not met. Release was result of maintenance. Staff opened body bleed to drain valve. Upon completing maintenance, staff closed the body bleed but did not get it fully tightened, resulting in a small drip type of release.
Detailed record list
Report Received Date
2021-06-14 00:00:00
Iyear
2021
Report Number
20210172
Supplemental Number
35529
Report Type
Supplemental Final
Operator Id
2170
Name
Cenex Pipeline Llc
Operator Street Address
803 Hwy 212 S (Po Box 909)
Operator City Name
Laurel
Operator State Abbreviation
MT
Operator Postal Code
59044
Local Datetime
2021-05-11 10:17:00
Location Latitude
47.014696
Location Longitude
-97.196908
Commodity Released Type
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype
Gasoline (Non-Ethanol)
Unintentional Release Bbls
0.7
Recovered Bbls
0.7
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
Incident Identified Datetime
2021-05-11 10:17:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Shutdown Due Accident Ind
No
Shutdown Explain
Pipeline Segment Was Not Operating At The Time Of The Release.
On Site Datetime
2021-05-11 10:17:00
Nrc Rpt Num
Nrc Notification Not Required
Ignite Ind
No
Explode Ind
No
Upstream Valve Type Ind
Remotely Controlled
Downstream Valve Type Ind
Remotely Controlled
Num Pub Evacuated
0
Pipe Fac Name
Bv 232
Segment Name
New Rockford To Fargo
Onshore State Abbreviation
Nd
Onshore Postal Code
58004
Onshore City Name
Not Within A Municipality
Onshore County Name
Cass
Designated Location
Milepost/valve Station
Designated Name
Bv 232
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Valve
Valve Type
Mainline
Valve Mainline Type
Ball
Valve Manufacturer
Balon
Installation Year
2018
Manufactured Year
2018
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Other
Leak Type Other
Bv Body Bleed Valve
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
No
Est Cost Oper Paid
500
Est Cost Gas Released
100
Est Cost Prop Damage
0
Est Cost Emergency
15000
Est Cost Environmental
0
Est Cost Other
500
Est Cost Other Details
Phmsa Reporting And Data Collection Efforts.
Prpty
16100
Accident Psig
725
Mop Psig
1440
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
Unknown
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Small volume of product dripping from bleeder on valve body that was corrected by field staff within minutes of arriving on-site, as witnessed by a PHMSA inspector that was performing the field portion of an integrated inspection. Segment was shutdown at the time of the release and kept shutdown until the bleeder was tightened and stopped dripping product. Controller and field staff took appropriate actions when responding to the incident.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Incorrect Operation
Cause Details
Other Incorrect Operation
Operation Type
Other Incorrect Operation
Operation Details
Valve Body Bleed Not Fully Tightened After Semi-Annual Routine Maintenance.
Related Failure Follow Ind
Yes
Category Type
Routine Maintenance
Operator Qualification Ind
Yes
Qualified Individuals
Yes, They Were Qualified For The Task(S)
Preparer Name
M******* S*****
Preparer Title
Manager Dot Compliacne
Preparer Email
M**************@c*****.com
Preparer Telephone
4066285293
Prepared Date
2021-07-21 00:00:00
Authorizer Name
G*** B****
Authorizer Telephone
4066285200
Authorizer Title
Vp Pipelines And Terminals
Authorizer Email
G*********@c*****.com
Narrative
During the field portion of a PHMSA integrated inspection on may 11, 2021, block valve 232 was found by cenex pipeline staff and the PHMSA inspector to be dripping a small volume of product from the body bleed valve. Controllers opened a downstream valve to bleed pressure/volume away from the site and oq qualified field staff tightened the bleed within minutes of arriving on-site to stop the leak. No repair was needed beyond tightening the bleed. Release estimate was based on volume of soil cleanup associated with the release. No leak alarms were received because the leak alarm thresholds were not met. Release was result of maintenance. Staff opened body bleed to drain valve. Upon completing maintenance, staff closed the body bleed but did not get it fully tightened, resulting in a small drip type of release.
| Report Received Date | 2021-06-14 00:00:00 |
|---|---|
| Iyear | 2021 |
| Report Number | 20210172 |
| Supplemental Number | 35529 |
| Report Type | Supplemental Final |
| Operator Id | 2170 PHMSA Enforcement |
| Name | Cenex Pipeline Llc |
| Operator Street Address | 803 Hwy 212 S (Po Box 909) |
| Operator City Name | Laurel |
| Operator State Abbreviation | MT |
| Operator Postal Code | 59044 |
| Local Datetime | 2021-05-11 10:17:00 |
| Location Latitude | 47.014696 Google Maps OpenStreetMap |
| Location Longitude | -97.196908 Google Maps OpenStreetMap |
| Commodity Released Type | Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions |
| Commodity Subtype | Gasoline (Non-Ethanol) |
| Unintentional Release Bbls | 0.7 |
| Recovered Bbls | 0.7 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Local Operating Personnel, Including Contractors |
| Operator Type | Operator Employee |
| Incident Identified Datetime | 2021-05-11 10:17:00 |
| System Part Involved | Onshore Pipeline, Including Valve Sites |
| On Off Shore | Onshore |
| Shutdown Due Accident Ind | No |
| Shutdown Explain | Pipeline Segment Was Not Operating At The Time Of The Release. |
| On Site Datetime | 2021-05-11 10:17:00 |
| Nrc Rpt Num | Nrc Notification Not Required NRC Report How to search |
| Ignite Ind | No |
| Explode Ind | No |
| Upstream Valve Type Ind | Remotely Controlled |
| Downstream Valve Type Ind | Remotely Controlled |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Bv 232 |
| Segment Name | New Rockford To Fargo |
| Onshore State Abbreviation | Nd |
| Onshore Postal Code | 58004 |
| Onshore City Name | Not Within A Municipality |
| Onshore County Name | Cass |
| Designated Location | Milepost/valve Station |
| Designated Name | Bv 232 |
| Federal | No |
| Location Type | Pipeline Right-Of-Way |
| Incident Area Type | Aboveground |
| Incident Area Subtype | Typical Aboveground Facility Piping Or Appurtenance |
| Crossing | No |
| Pipe Facility Type | Interstate |
| Item Involved | Valve |
| Valve Type | Mainline |
| Valve Mainline Type | Ball |
| Valve Manufacturer | Balon |
| Installation Year | 2018 |
| Manufactured Year | 2018 |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Other |
| Leak Type Other | Bv Body Bleed Valve |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | No |
| Remediation Ind | No |
| Water Contam Ind | No |
| Could Be Hca | Yes |
| Commodity Reached Hca | No |
| Est Cost Oper Paid | 500 |
| Est Cost Gas Released | 100 |
| Est Cost Prop Damage | 0 |
| Est Cost Emergency | 15000 |
| Est Cost Environmental | 0 |
| Est Cost Other | 500 |
| Est Cost Other Details | Phmsa Reporting And Data Collection Efforts. |
| Prpty | 16100 |
| Accident Psig | 725 |
| Mop Psig | 1440 |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Length Segment Isolated | Unknown |
| Internal Inspection Ind | Yes |
| Operation Complications Ind | No |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | No |
| Cpm In Place Ind | Yes |
| Cpm Operating Ind | Yes |
| Cpm Functional Ind | Yes |
| Cpm Detection Ind | No |
| Cpm Conf Ind | No |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | Small volume of product dripping from bleeder on valve body that was corrected by field staff within minutes of arriving on-site, as witnessed by a PHMSA inspector that was performing the field portion of an integrated inspection. Segment was shutdown at the time of the release and kept shutdown until the bleeder was tightened and stopped dripping product. Controller and field staff took appropriate actions when responding to the incident. |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Incorrect Operation |
| Cause Details | Other Incorrect Operation |
| Operation Type | Other Incorrect Operation |
| Operation Details | Valve Body Bleed Not Fully Tightened After Semi-Annual Routine Maintenance. |
| Related Failure Follow Ind | Yes |
| Category Type | Routine Maintenance |
| Operator Qualification Ind | Yes |
| Qualified Individuals | Yes, They Were Qualified For The Task(S) |
| Preparer Name | M******* S***** |
| Preparer Title | Manager Dot Compliacne |
| Preparer Email | M**************@c*****.com |
| Preparer Telephone | 4066285293 |
| Prepared Date | 2021-07-21 00:00:00 |
| Authorizer Name | G*** B**** |
| Authorizer Telephone | 4066285200 |
| Authorizer Title | Vp Pipelines And Terminals |
| Authorizer Email | G*********@c*****.com |
| Narrative | During the field portion of a PHMSA integrated inspection on may 11, 2021, block valve 232 was found by cenex pipeline staff and the PHMSA inspector to be dripping a small volume of product from the body bleed valve. Controllers opened a downstream valve to bleed pressure/volume away from the site and oq qualified field staff tightened the bleed within minutes of arriving on-site to stop the leak. No repair was needed beyond tightening the bleed. Release estimate was based on volume of soil cleanup associated with the release. No leak alarms were received because the leak alarm thresholds were not met. Release was result of maintenance. Staff opened body bleed to drain valve. Upon completing maintenance, staff closed the body bleed but did not get it fully tightened, resulting in a small drip type of release. |