GD incident on 2021-10-22 — TX

Operator
Brenham Utility, City Of
Cause
Excavation Issue
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$2,904
Incident datetime
2021-10-22 09:20
Report number
Location
TX, WASHINGTON
Narrative
The excavator was working on the access road for the entrance to the new shopping center. The project has been ongoing since february. They had not started on this section until the last couple of months. After removing an old driveway that existed along the road they had changed the grade of the area by removing a portion of the dirt that covered the 6" main. There had been a locate done for a fiber contractor that was basically along the same path of the road contractors worksite. The main was flagged and marked correctly along the path. All the markings were present when burts construction removed some more material with a dozer and then brought in a reclaimer to mix the dirt and road base for stabilization. When the mixer started to till the dirt it hit the line damaging it and causing an ignition. The equipment operator shut off the machine and jumped off but but did get his right arm burnt to the point he was taken to the hospital by helicopter. The reclaimer was engulfed in flames and completely destroyed. We closed a valve off on the west side of the damage and then dug up the 6" and squeezed it off to stop the flow of gas on the east side. The fire department put the fire out. I contacted the rrc by phone and also the nrc. The rrc sent investigators out to access the scene and investigate it. I checked on the employee who was injured and his supervisor said he was released from the hospital that same night with severe burns on his right arm. The damaged reclaimer was removed from the spot on the 25th of october 2021. On tuesday the 26th october 2021 we dug up, lowered and repaired the line was damaged with the rrc inspectors on site. On thursday the gas department exposed the gas main along the area in 4 different spots verifying its location and depth. All were already correctly marked but these areas had not had dirt removed from the top of them. The city of brenham gas depoartment will continue to mark our facilities in accordance with the texas aministrative code title 16 part 1 chapter 18 for underground pipeline damage prevention. We have put in place in our plan review for developement services under the gas department comments section verbiage stating that the builder, contractor, developer and/or excavators that take part in these work projects will maintain contact with the city of brenham and be aware of their responsibility of protection of existing city untilities on these sites during the duration of the project.
Detailed record list
Occurred At
2021-10-22 09:20:00
Year
2021
Report Received Date
2021-11-16 00:00:00
Iyear
2021.0
Report Number
20210095.0
Supplemental Number
36213.0
Report Type
Supplemental Final
Operator Id
Name
Brenham Utility, City Of
Operator Street Address
200 W Vulcan St
Operator City Name
Brenham
Operator State Abbreviation
TX
Operator Postal Code
77834
Local Datetime
2021-10-22 09:20:00
Time Zone
Central
Daylight Savings Ind
No
Location Street Address
H*********@ ******************
Location City Name
Brenham
Location County Name
Washington
Location State Abbreviation
TX
Location Postal Code
77833
Location Latitude
Location Longitude
Flow Cont Key Crit Ind
Yes
Flow Cont Squeeze Off Ind
Yes
Nrc Rpt Datetime
2021-10-22 11:35:00
Nrc Rpt Num
Additional Nrc Report Numbers
1320663
Commodity Released Type
Natural Gas
Unintentional Release
250.0
Intentional Release
0.0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Ignite Ind
Yes
Ignite Datetime
2021-10-22 09:20:00
How Extinguished
Local/state/federal Emergency Responder
Gas Consumed By Fire In Mcf
250
Explode Ind
No
Num Pub Evacuated
0.0
Incident Identified Datetime
2021-10-22 09:20:00
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Initial Responder Com Datetime
2021-10-22 09:20:00
On Site Datetime
2021-10-22 09:27:00
Federal
No
Location Type
Public Property
Incident Area Type
Underground
Incident Area Subtype
Exposed Due To Excavation
Depth Of Cover
18.0
Other Underground Facilities
No
Crossing
No
Pipe Facility Type
Municipally Owned
System Part Involved
Main
Installation Year
1994.0
Manufactured Year
1992.0
Pipe Diameter
6.0
Pipe Specification
Astm D2513
Pipe Manufacturer
Driscopipe
Material Involved
Plastic
Plastic Type
Polyethylene (Pe)
Plastic Sdr
11.5
Material Pe Pipe Code
2406
Release Type
Mechanical Puncture
Puncture Axial
1.0
Puncture Circum
1.5
Class Location Type
Class 3 Location
Est Cost Oper Paid
0.0
Est Cost Prop Damage
2904.0
Est Cost Emergency
583.0
Est Cost Other
2025.0
Est Cost Other Details
Cost Of Brenham Fd Along With 3 Other Fire Departments Mutual Aid
Gas Cost In Mcf
8.05
Est Cost Unintentional Release
2013.0
Est Cost Intentional Release
0.0
Prpty
7525.0
Commercial Affected
0.0
Industrial Affected
0.0
Residences Affected
0.0
Num Persons Hosp Not Ovnght
1.0
Num Injured Treated By Emt
0.0
Num Resident Building Affctd
0.0
Num Business Building Affctd
0.0
Accident Psig
28.0
Normal Psig
28.0
Mop Psig
60.0
Mop Cfr Section
192.619(A)(4)
Maop Established Date
1980-01-01 00:00:00
Accident Pressure
Pressure Did Not Exceed Maop
Gas Odorized System Type
Injection Pump
Gas Odorized Lvl Not Msrd Ind
Yes
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
Yes
Scada Conf Ind
No
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
The pressure changes was from the damage due to the pipeline.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Excavation Damage
Cause Details
Excavation Damage By Third Party
Ex Party Type
Excavation Damage By Third Party
Prior Notification Ind
Yes
One Call System Ind
Yes
State Law Exempt Ind
No
Notify Cga Dirt
Yes
Public Row Ind
Yes
Public Subtype
State Highway
Excavator Type
Contractor
Excavator Equipment
Unknown/other
Work Performed
Road Work
One Call Notified Ind
Yes
One Call Ticket Num
2178065546
One Call Center Name
Texas 811 Is The Only One-Call
Locator Type
Utility Owner
Visible Marks
Yes
Service Interruption
Unknown/other
Root Cause Category
Excavation Issue
Root Cause Type
Improper Excavation Practice Not Listed Above
Preparer Name
A*** B******
Preparer Title
Gas Superintindent
Preparer Email
A*******@c************.org
Preparer Telephone
19793377416
Preparer Fax
19793377419
Local Contact Name
A*** B******
Local Contact Email
A*******@c************.org
Local Contact Telephone
19794511772
Authorizer Name
A*** B******
Authorizer Title
Gas Superintindent
Authorizer Telephone
19794511772
Authorizer Email
A*******@c************.org
Narrative
The excavator was working on the access road for the entrance to the new shopping center. The project has been ongoing since february. They had not started on this section until the last couple of months. After removing an old driveway that existed along the road they had changed the grade of the area by removing a portion of the dirt that covered the 6" main. There had been a locate done for a fiber contractor that was basically along the same path of the road contractors worksite. The main was flagged and marked correctly along the path. All the markings were present when burts construction removed some more material with a dozer and then brought in a reclaimer to mix the dirt and road base for stabilization. When the mixer started to till the dirt it hit the line damaging it and causing an ignition. The equipment operator shut off the machine and jumped off but but did get his right arm burnt to the point he was taken to the hospital by helicopter. The reclaimer was engulfed in flames and completely destroyed. We closed a valve off on the west side of the damage and then dug up the 6" and squeezed it off to stop the flow of gas on the east side. The fire department put the fire out. I contacted the rrc by phone and also the nrc. The rrc sent investigators out to access the scene and investigate it. I checked on the employee who was injured and his supervisor said he was released from the hospital that same night with severe burns on his right arm. The damaged reclaimer was removed from the spot on the 25th of october 2021. On tuesday the 26th october 2021 we dug up, lowered and repaired the line was damaged with the rrc inspectors on site. On thursday the gas department exposed the gas main along the area in 4 different spots verifying its location and depth. All were already correctly marked but these areas had not had dirt removed from the top of them. The city of brenham gas depoartment will continue to mark our facilities in accordance with the texas aministrative code title 16 part 1 chapter 18 for underground pipeline damage prevention. We have put in place in our plan review for developement services under the gas department comments section verbiage stating that the builder, contractor, developer and/or excavators that take part in these work projects will maintain contact with the city of brenham and be aware of their responsibility of protection of existing city untilities on these sites during the duration of the project.
Occurred At 2021-10-22 09:20:00
Year 2021
Report Received Date 2021-11-16 00:00:00
Iyear 2021.0
Report Number 20210095.0
Supplemental Number 36213.0
Report Type Supplemental Final
Operator Id 1720 PHMSA Enforcement
Name Brenham Utility, City Of
Operator Street Address 200 W Vulcan St
Operator City Name Brenham
Operator State Abbreviation TX
Operator Postal Code 77834
Local Datetime 2021-10-22 09:20:00
Time Zone Central
Daylight Savings Ind No
Location Street Address H*********@ ******************
Location City Name Brenham
Location County Name Washington
Location State Abbreviation TX
Location Postal Code 77833
Location Latitude 30.142049 Google Maps OpenStreetMap
Location Longitude -96.382068 Google Maps OpenStreetMap
Flow Cont Key Crit Ind Yes
Flow Cont Squeeze Off Ind Yes
Nrc Rpt Datetime 2021-10-22 11:35:00
Nrc Rpt Num 1320155 NRC Report How to search
Additional Nrc Report Numbers 1320663
Commodity Released Type Natural Gas
Unintentional Release 250.0
Intentional Release 0.0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Ignite Ind Yes
Ignite Datetime 2021-10-22 09:20:00
How Extinguished Local/state/federal Emergency Responder
Gas Consumed By Fire In Mcf 250
Explode Ind No
Num Pub Evacuated 0.0
Incident Identified Datetime 2021-10-22 09:20:00
Communication State Fed Ind Yes
Party Initiated Communication Operator
Initial Responder Com Datetime 2021-10-22 09:20:00
On Site Datetime 2021-10-22 09:27:00
Federal No
Location Type Public Property
Incident Area Type Underground
Incident Area Subtype Exposed Due To Excavation
Depth Of Cover 18.0
Other Underground Facilities No
Crossing No
Pipe Facility Type Municipally Owned
System Part Involved Main
Installation Year 1994.0
Manufactured Year 1992.0
Pipe Diameter 6.0
Pipe Specification Astm D2513
Pipe Manufacturer Driscopipe
Material Involved Plastic
Plastic Type Polyethylene (Pe)
Plastic Sdr 11.5
Material Pe Pipe Code 2406
Release Type Mechanical Puncture
Puncture Axial 1.0
Puncture Circum 1.5
Class Location Type Class 3 Location
Est Cost Oper Paid 0.0
Est Cost Prop Damage 2904.0
Est Cost Emergency 583.0
Est Cost Other 2025.0
Est Cost Other Details Cost Of Brenham Fd Along With 3 Other Fire Departments Mutual Aid
Gas Cost In Mcf 8.05
Est Cost Unintentional Release 2013.0
Est Cost Intentional Release 0.0
Prpty 7525.0
Commercial Affected 0.0
Industrial Affected 0.0
Residences Affected 0.0
Num Persons Hosp Not Ovnght 1.0
Num Injured Treated By Emt 0.0
Num Resident Building Affctd 0.0
Num Business Building Affctd 0.0
Accident Psig 28.0
Normal Psig 28.0
Mop Psig 60.0
Mop Cfr Section 192.619(A)(4) View CFR 49 §192
Maop Established Date 1980-01-01 00:00:00
Accident Pressure Pressure Did Not Exceed Maop
Gas Odorized System Type Injection Pump
Gas Odorized Lvl Not Msrd Ind Yes
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind Yes
Scada Conf Ind No
Accident Identifier Local Operating Personnel, Including Contractors
Operator Type Operator Employee
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details The pressure changes was from the damage due to the pipeline.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Excavation Damage
Cause Details Excavation Damage By Third Party
Ex Party Type Excavation Damage By Third Party
Prior Notification Ind Yes
One Call System Ind Yes
State Law Exempt Ind No
Notify Cga Dirt Yes
Public Row Ind Yes
Public Subtype State Highway
Excavator Type Contractor
Excavator Equipment Unknown/other
Work Performed Road Work
One Call Notified Ind Yes
One Call Ticket Num 2178065546
One Call Center Name Texas 811 Is The Only One-Call
Locator Type Utility Owner
Visible Marks Yes
Service Interruption Unknown/other
Root Cause Category Excavation Issue
Root Cause Type Improper Excavation Practice Not Listed Above
Preparer Name A*** B******
Preparer Title Gas Superintindent
Preparer Email A*******@c************.org
Preparer Telephone 19793377416
Preparer Fax 19793377419
Local Contact Name A*** B******
Local Contact Email A*******@c************.org
Local Contact Telephone 19794511772
Authorizer Name A*** B******
Authorizer Title Gas Superintindent
Authorizer Telephone 19794511772
Authorizer Email A*******@c************.org
Narrative The excavator was working on the access road for the entrance to the new shopping center. The project has been ongoing since february. They had not started on this section until the last couple of months. After removing an old driveway that existed along the road they had changed the grade of the area by removing a portion of the dirt that covered the 6" main. There had been a locate done for a fiber contractor that was basically along the same path of the road contractors worksite. The main was flagged and marked correctly along the path. All the markings were present when burts construction removed some more material with a dozer and then brought in a reclaimer to mix the dirt and road base for stabilization. When the mixer started to till the dirt it hit the line damaging it and causing an ignition. The equipment operator shut off the machine and jumped off but but did get his right arm burnt to the point he was taken to the hospital by helicopter. The reclaimer was engulfed in flames and completely destroyed. We closed a valve off on the west side of the damage and then dug up the 6" and squeezed it off to stop the flow of gas on the east side. The fire department put the fire out. I contacted the rrc by phone and also the nrc. The rrc sent investigators out to access the scene and investigate it. I checked on the employee who was injured and his supervisor said he was released from the hospital that same night with severe burns on his right arm. The damaged reclaimer was removed from the spot on the 25th of october 2021. On tuesday the 26th october 2021 we dug up, lowered and repaired the line was damaged with the rrc inspectors on site. On thursday the gas department exposed the gas main along the area in 4 different spots verifying its location and depth. All were already correctly marked but these areas had not had dirt removed from the top of them. The city of brenham gas depoartment will continue to mark our facilities in accordance with the texas aministrative code title 16 part 1 chapter 18 for underground pipeline damage prevention. We have put in place in our plan review for developement services under the gas department comments section verbiage stating that the builder, contractor, developer and/or excavators that take part in these work projects will maintain contact with the city of brenham and be aware of their responsibility of protection of existing city untilities on these sites during the duration of the project.

All rights reserved. Copyright © by ClearPHMSA