Incident details
Operator, cause, commodity and consequences with raw source fields.
GD incident on 2021-08-25 — CA
Operator
Pacific Gas & Electric Co
Cause
Locating Issue
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$498,000
Incident datetime
2021-08-25 09:55
Report number
Location
CA, SANTA CLARA
Narrative
A third-party contractor damaged a un-marked 3" steel gas main during horizontal boring. The 3" gas main was not located by pg&e and was struck by a 10" reamer causing a release of gas. Gas traveled in storm and sewer systems as well as communications vaults. Crews on site vented the gas to prevent further migration and isolate. Safe zones were established, and the fd assisted with evacuations within the established zone. There were no injuries and/or fatalities. This incident is being reported due to the damage threshold reporting criteria of $122k+.
Detailed record list
Occurred At
2021-08-25 09:55:00
Year
2021
Report Received Date
2021-09-24 00:00:00
Iyear
2021.0
Report Number
20210083.0
Supplemental Number
39733.0
Report Type
Supplemental Final
Operator Id
15007
Name
Pacific Gas & Electric Co
Operator Street Address
6121 Bollinger Canyon Rd.
Operator City Name
San Ramon
Operator State Abbreviation
CA
Operator Postal Code
94583
Local Datetime
2021-08-25 09:55:00
Time Zone
Pacific
Daylight Savings Ind
Yes
Location Street Address
Race Street & Park Avenue
Location City Name
San Jose
Location County Name
Santa Clara
Location State Abbreviation
CA
Location Postal Code
95126
Location Latitude
37.325993
Location Longitude
-121.911497
Flow Cont Squeeze Off Ind
Yes
Flow Cont Stopple Fitng Ind
Yes
Nrc Rpt Datetime
2021-08-25 13:53:00
Nrc Rpt Num
1314710
Additional Nrc Report Numbers
1314934
Commodity Released Type
Natural Gas
Unintentional Release
6107.0
Intentional Release
0.0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Ignite Ind
No
Num Pub Evacuated
300.0
Incident Identified Datetime
2021-08-25 09:55:00
On Site Datetime
2021-08-25 10:03:00
Confirmed Discovery Datetime
2021-08-25 09:55:00
Federal
No
Location Type
Public Property
Incident Area Type
Underground
Incident Area Subtype
Under Pavement
Depth Of Cover
32.0
Other Underground Facilities
Yes
Crossing
No
Pipe Facility Type
Investor Owned
System Part Involved
Main
Pipe Diameter
3.0
Pipe Specification
Steel
Pipe Manufacturer
Unknown
Material Involved
Steel
Steel Seam Type
Other
Steel Seam Type Details
Unknown
Release Type
Mechanical Puncture
Puncture Axial
2.0
Puncture Circum
2.0
Class Location Type
Class 3 Location
Est Cost Oper Paid
0.0
Est Cost Prop Damage
498000.0
Est Cost Emergency
0.0
Est Cost Other
0.0
Gas Cost In Mcf
8.66
Est Cost Unintentional Release
52887.0
Est Cost Intentional Release
0.0
Prpty
550887.0
Commercial Affected
15.0
Industrial Affected
0.0
Residences Affected
28.0
Num Persons Hosp Not Ovnght
0.0
Num Injured Treated By Emt
1.0
Num Resident Building Affctd
28.0
Num Business Building Affctd
15.0
Accident Psig
50.0
Normal Psig
50.0
Mop Psig
60.0
Mop Cfr Section
192.619(A)(2)
Maop Established Date
1975-06-10 00:00:00
Accident Pressure
Pressure Did Not Exceed Maop
Gas Odorized System Type
Odorized By Others
Gas Odorized Lvl Not Msrd Ind
Yes
Scada In Place Ind
No
Accident Identifier
Notification From Emergency Responder
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Dig-in incident
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Excavation Damage
Cause Details
Excavation Damage By Third Party
Ex Party Type
Excavation Damage By Third Party
Prior Notification Ind
Yes
One Call System Ind
Yes
State Law Exempt Ind
No
Notify Cga Dirt
No
Public Row Ind
Yes
Public Subtype
City Street
Joint Trench Ind
No
Cross Bore Ind
Yes
Depth Of Grade
> 36�
Excavator Type
Contractor
Excavator Equipment
Boring
Work Performed
Telecommunications
One Call Notified Ind
Yes
One Call Ticket Num
X118101646
One Call Center Name
811 Dig
White Lined Ind
Yes
Locator Type
Facility Owner
Visible Marks
Yes
Service Interruption
Yes
Service Interruption Hours
23.0
Root Cause Category
Locating Issue
Root Cause Type
Facility Not Marked Due To Locator Error
Preparer Name
R*** D*****
Preparer Title
Gas Program Manager
Preparer Email
R**********@p**.com
Preparer Telephone
510-298-7063
Local Contact Name
F****** Y**
Local Contact Email
F**********@p**.com
Local Contact Telephone
925-200-4736
Authorizer Name
R*** D*****
Authorizer Title
Gas Program Manager
Authorizer Telephone
510-298-7063
Authorizer Email
R**********@p**.com
Narrative
A third-party contractor damaged a un-marked 3" steel gas main during horizontal boring. The 3" gas main was not located by pg&e and was struck by a 10" reamer causing a release of gas. Gas traveled in storm and sewer systems as well as communications vaults. Crews on site vented the gas to prevent further migration and isolate. Safe zones were established, and the fd assisted with evacuations within the established zone. There were no injuries and/or fatalities. This incident is being reported due to the damage threshold reporting criteria of $122k+.
| Occurred At | 2021-08-25 09:55:00 |
|---|---|
| Year | 2021 |
| Report Received Date | 2021-09-24 00:00:00 |
| Iyear | 2021.0 |
| Report Number | 20210083.0 |
| Supplemental Number | 39733.0 |
| Report Type | Supplemental Final |
| Operator Id | 15007 PHMSA Enforcement |
| Name | Pacific Gas & Electric Co |
| Operator Street Address | 6121 Bollinger Canyon Rd. |
| Operator City Name | San Ramon |
| Operator State Abbreviation | CA |
| Operator Postal Code | 94583 |
| Local Datetime | 2021-08-25 09:55:00 |
| Time Zone | Pacific |
| Daylight Savings Ind | Yes |
| Location Street Address | Race Street & Park Avenue |
| Location City Name | San Jose |
| Location County Name | Santa Clara |
| Location State Abbreviation | CA |
| Location Postal Code | 95126 |
| Location Latitude | 37.325993 Google Maps OpenStreetMap |
| Location Longitude | -121.911497 Google Maps OpenStreetMap |
| Flow Cont Squeeze Off Ind | Yes |
| Flow Cont Stopple Fitng Ind | Yes |
| Nrc Rpt Datetime | 2021-08-25 13:53:00 |
| Nrc Rpt Num | 1314710 NRC Report How to search |
| Additional Nrc Report Numbers | 1314934 |
| Commodity Released Type | Natural Gas |
| Unintentional Release | 6107.0 |
| Intentional Release | 0.0 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Ignite Ind | No |
| Num Pub Evacuated | 300.0 |
| Incident Identified Datetime | 2021-08-25 09:55:00 |
| On Site Datetime | 2021-08-25 10:03:00 |
| Confirmed Discovery Datetime | 2021-08-25 09:55:00 |
| Federal | No |
| Location Type | Public Property |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Pavement |
| Depth Of Cover | 32.0 |
| Other Underground Facilities | Yes |
| Crossing | No |
| Pipe Facility Type | Investor Owned |
| System Part Involved | Main |
| Pipe Diameter | 3.0 |
| Pipe Specification | Steel |
| Pipe Manufacturer | Unknown |
| Material Involved | Steel |
| Steel Seam Type | Other |
| Steel Seam Type Details | Unknown |
| Release Type | Mechanical Puncture |
| Puncture Axial | 2.0 |
| Puncture Circum | 2.0 |
| Class Location Type | Class 3 Location |
| Est Cost Oper Paid | 0.0 |
| Est Cost Prop Damage | 498000.0 |
| Est Cost Emergency | 0.0 |
| Est Cost Other | 0.0 |
| Gas Cost In Mcf | 8.66 |
| Est Cost Unintentional Release | 52887.0 |
| Est Cost Intentional Release | 0.0 |
| Prpty | 550887.0 |
| Commercial Affected | 15.0 |
| Industrial Affected | 0.0 |
| Residences Affected | 28.0 |
| Num Persons Hosp Not Ovnght | 0.0 |
| Num Injured Treated By Emt | 1.0 |
| Num Resident Building Affctd | 28.0 |
| Num Business Building Affctd | 15.0 |
| Accident Psig | 50.0 |
| Normal Psig | 50.0 |
| Mop Psig | 60.0 |
| Mop Cfr Section | 192.619(A)(2) View CFR 49 §192 |
| Maop Established Date | 1975-06-10 00:00:00 |
| Accident Pressure | Pressure Did Not Exceed Maop |
| Gas Odorized System Type | Odorized By Others |
| Gas Odorized Lvl Not Msrd Ind | Yes |
| Scada In Place Ind | No |
| Accident Identifier | Notification From Emergency Responder |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | Dig-in incident |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Excavation Damage |
| Cause Details | Excavation Damage By Third Party |
| Ex Party Type | Excavation Damage By Third Party |
| Prior Notification Ind | Yes |
| One Call System Ind | Yes |
| State Law Exempt Ind | No |
| Notify Cga Dirt | No |
| Public Row Ind | Yes |
| Public Subtype | City Street |
| Joint Trench Ind | No |
| Cross Bore Ind | Yes |
| Depth Of Grade | > 36� |
| Excavator Type | Contractor |
| Excavator Equipment | Boring |
| Work Performed | Telecommunications |
| One Call Notified Ind | Yes |
| One Call Ticket Num | X118101646 |
| One Call Center Name | 811 Dig |
| White Lined Ind | Yes |
| Locator Type | Facility Owner |
| Visible Marks | Yes |
| Service Interruption | Yes |
| Service Interruption Hours | 23.0 |
| Root Cause Category | Locating Issue |
| Root Cause Type | Facility Not Marked Due To Locator Error |
| Preparer Name | R*** D***** |
| Preparer Title | Gas Program Manager |
| Preparer Email | R**********@p**.com |
| Preparer Telephone | 510-298-7063 |
| Local Contact Name | F****** Y** |
| Local Contact Email | F**********@p**.com |
| Local Contact Telephone | 925-200-4736 |
| Authorizer Name | R*** D***** |
| Authorizer Title | Gas Program Manager |
| Authorizer Telephone | 510-298-7063 |
| Authorizer Email | R**********@p**.com |
| Narrative | A third-party contractor damaged a un-marked 3" steel gas main during horizontal boring. The 3" gas main was not located by pg&e and was struck by a 10" reamer causing a release of gas. Gas traveled in storm and sewer systems as well as communications vaults. Crews on site vented the gas to prevent further migration and isolate. Safe zones were established, and the fd assisted with evacuations within the established zone. There were no injuries and/or fatalities. This incident is being reported due to the damage threshold reporting criteria of $122k+. |