Incident details
Operator, cause, commodity and consequences with raw source fields.
GD incident on 2021-06-07 — CT
Operator
Southern Connecticut Gas Co
Cause
Other Outside Force Damage
Commodity
Natural Gas
Program
GD
Damage and Injuries
1 fatality
0 injuries
Property damage (nominal)
$5,000
Incident datetime
2021-06-07 09:16
Report number
Location
CT, NEW HAVEN
Narrative
At 08:59 am june 7, 2021, scg received a call from the milford fire department regarding a gas fire involving a vehicle at 500 bic drive building #4 in milford. Scg first responders were informed that a commercial type lawn mower had struck the gas service regulator to the address resulting in a gas leak and fire. The fire department reported that approximately 50 occupants of the building were evacuated. The fire was extinguished by the milford fire department. The gas was shut off to the building by scg. The operator of the lawnmower sustained burns from the gas fire, and was taken to the hospital. Scg has learned that the operator of the lawnmower died of his injuries on july 2, 2021. This supplemental report updates the number of fatalities from "0" to "1" to reflect the death of the lawnmower operator.
Detailed record list
Occurred At
2021-06-07 09:16:00
Year
2021
Report Received Date
2021-07-14 00:00:00
Iyear
2021.0
Report Number
20210063.0
Supplemental Number
35898.0
Report Type
Supplemental
Operator Id
18496
Name
Southern Connecticut Gas Co
Operator Street Address
60 Marsh Hill Road
Operator City Name
Orange
Operator State Abbreviation
CT
Operator Postal Code
06477
Local Datetime
2021-06-07 08:59:00
Time Zone
Eastern
Daylight Savings Ind
Yes
Location Street Address
500 Bic Drive Bldg #4
Location City Name
Milford
Location County Name
New Haven
Location State Abbreviation
CT
Location Postal Code
06461
Location Latitude
41.21948
Location Longitude
-73.10062
Flow Cont Service Valve Ind
Yes
Nrc Rpt Datetime
2021-06-07 13:24:00
Nrc Rpt Num
1307077
Additional Nrc Report Numbers
1307343
Commodity Released Type
Natural Gas
Unintentional Release
38.0
Intentional Release
0.0
Fatality Ind
Yes
Num Emp Fatalities
0
Num Contr Fatalities
0
Num Er Fatalities
0
Num Worker Fatalities
1
Num Gp Fatalities
0
Fatal
1
Injury Ind
No
Injure
0
Ignite Ind
Yes
Ignite Datetime
2021-06-07 08:59:00
How Extinguished
Local/state/federal Emergency Responder
Gas Consumed By Fire In Mcf
17
Explode Ind
No
Num Pub Evacuated
50.0
Incident Identified Datetime
2021-06-07 09:16:00
On Site Datetime
2021-06-07 09:16:00
Federal
No
Location Type
Private Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance (E.g. Value Or Regulator Station, Outdoor Meter Set)
Crossing
No
Pipe Facility Type
Investor Owned
System Part Involved
Service Riser
Installation Year
1988.0
Customer Type
Non-Residential With Meter Capacity 1,000 Scfh Or Higher
Was Efv Installed Before Ind
No
Curb Valve Inst Before Inc Ind
Yes
Material Involved
Steel
Steel Seam Type
Other
Steel Seam Type Details
Service Regulator Body
Release Type
Other
Release Type Details
The Service Regulator Was Damaged By Being Hit By A Commercial Lawn Mower, Breaking The Operating Diaphram Off Of The Regulator Body Exposing The Regulator Orifice Resulting In A Leak.
Class Location Type
Class 2 Location
Est Cost Oper Paid
35000.0
Est Cost Prop Damage
5000.0
Est Cost Emergency
5000.0
Est Cost Other
0.0
Est Cost Other Details
These Are Estimates Only. Actual Costs Not Yet Known.
Gas Cost In Mcf
2.0
Est Cost Unintentional Release
76.0
Est Cost Intentional Release
0.0
Prpty
45076.0
Commercial Affected
1.0
Industrial Affected
0.0
Residences Affected
0.0
Num Persons Hosp Not Ovnght
0.0
Num Injured Treated By Emt
0.0
Num Resident Building Affctd
0.0
Num Business Building Affctd
1.0
Accident Psig
57.0
Normal Psig
57.0
Mop Psig
60.0
Mop Cfr Section
192.619(A)(2)
Maop Established Date
1994-03-25 00:00:00
Accident Pressure
Pressure Did Not Exceed Maop
Gas Odorized System Type
Drip
Gas Odorized Lvl Not Msrd Ind
Yes
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Accident Identifier
Notification From Emergency Responder
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
The incident was the result of damage from a lawwnmower breaking the service regulator on the riser resulting in a leak. No control room actions resulted in the incident.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Other Outside Force Damage
Cause Details
Damage By Car, Truck, Or Other Motorized Vehicle/equipment Not Engaged In Excavation
Outside Force Type
Damage By Car, Truck, Or Other Motorized Vehicle/equipment Not Engaged In Excavation
Vehicle Subtype
Third Party
Driver Issued Citation Ind
No
Driver In Control Ind
Unknown
Estimated Speed
Unknown
Vehicle Type
Motorcycle/atv
Vehicle Travel From
Off-Road
Vehicle Travel Distance Ft
0
Protections Installed Ind
No
Preparer Name
K**** G*****
Preparer Title
Manager Of Technical Services
Preparer Email
K******@s********.com
Preparer Telephone
203-795-7767
Preparer Fax
203-795-7784
Local Contact Name
J** M******
Local Contact Email
J*******@s********.com
Local Contact Telephone
203-650-7665
Authorizer Name
A* L*******
Authorizer Title
Vice President
Authorizer Telephone
203-257-5855
Authorizer Email
A**********@a*******.com
Narrative
At 08:59 am june 7, 2021, scg received a call from the milford fire department regarding a gas fire involving a vehicle at 500 bic drive building #4 in milford. Scg first responders were informed that a commercial type lawn mower had struck the gas service regulator to the address resulting in a gas leak and fire. The fire department reported that approximately 50 occupants of the building were evacuated. The fire was extinguished by the milford fire department. The gas was shut off to the building by scg. The operator of the lawnmower sustained burns from the gas fire, and was taken to the hospital. Scg has learned that the operator of the lawnmower died of his injuries on july 2, 2021. This supplemental report updates the number of fatalities from "0" to "1" to reflect the death of the lawnmower operator.
| Occurred At | 2021-06-07 09:16:00 |
|---|---|
| Year | 2021 |
| Report Received Date | 2021-07-14 00:00:00 |
| Iyear | 2021.0 |
| Report Number | 20210063.0 |
| Supplemental Number | 35898.0 |
| Report Type | Supplemental |
| Operator Id | 18496 PHMSA Enforcement |
| Name | Southern Connecticut Gas Co |
| Operator Street Address | 60 Marsh Hill Road |
| Operator City Name | Orange |
| Operator State Abbreviation | CT |
| Operator Postal Code | 06477 |
| Local Datetime | 2021-06-07 08:59:00 |
| Time Zone | Eastern |
| Daylight Savings Ind | Yes |
| Location Street Address | 500 Bic Drive Bldg #4 |
| Location City Name | Milford |
| Location County Name | New Haven |
| Location State Abbreviation | CT |
| Location Postal Code | 06461 |
| Location Latitude | 41.21948 Google Maps OpenStreetMap |
| Location Longitude | -73.10062 Google Maps OpenStreetMap |
| Flow Cont Service Valve Ind | Yes |
| Nrc Rpt Datetime | 2021-06-07 13:24:00 |
| Nrc Rpt Num | 1307077 NRC Report How to search |
| Additional Nrc Report Numbers | 1307343 |
| Commodity Released Type | Natural Gas |
| Unintentional Release | 38.0 |
| Intentional Release | 0.0 |
| Fatality Ind | Yes |
| Num Emp Fatalities | 0 |
| Num Contr Fatalities | 0 |
| Num Er Fatalities | 0 |
| Num Worker Fatalities | 1 |
| Num Gp Fatalities | 0 |
| Fatal | 1 |
| Injury Ind | No |
| Injure | 0 |
| Ignite Ind | Yes |
| Ignite Datetime | 2021-06-07 08:59:00 |
| How Extinguished | Local/state/federal Emergency Responder |
| Gas Consumed By Fire In Mcf | 17 |
| Explode Ind | No |
| Num Pub Evacuated | 50.0 |
| Incident Identified Datetime | 2021-06-07 09:16:00 |
| On Site Datetime | 2021-06-07 09:16:00 |
| Federal | No |
| Location Type | Private Property |
| Incident Area Type | Aboveground |
| Incident Area Subtype | Typical Aboveground Facility Piping Or Appurtenance (E.g. Value Or Regulator Station, Outdoor Meter Set) |
| Crossing | No |
| Pipe Facility Type | Investor Owned |
| System Part Involved | Service Riser |
| Installation Year | 1988.0 |
| Customer Type | Non-Residential With Meter Capacity 1,000 Scfh Or Higher |
| Was Efv Installed Before Ind | No |
| Curb Valve Inst Before Inc Ind | Yes |
| Material Involved | Steel |
| Steel Seam Type | Other |
| Steel Seam Type Details | Service Regulator Body |
| Release Type | Other |
| Release Type Details | The Service Regulator Was Damaged By Being Hit By A Commercial Lawn Mower, Breaking The Operating Diaphram Off Of The Regulator Body Exposing The Regulator Orifice Resulting In A Leak. |
| Class Location Type | Class 2 Location |
| Est Cost Oper Paid | 35000.0 |
| Est Cost Prop Damage | 5000.0 |
| Est Cost Emergency | 5000.0 |
| Est Cost Other | 0.0 |
| Est Cost Other Details | These Are Estimates Only. Actual Costs Not Yet Known. |
| Gas Cost In Mcf | 2.0 |
| Est Cost Unintentional Release | 76.0 |
| Est Cost Intentional Release | 0.0 |
| Prpty | 45076.0 |
| Commercial Affected | 1.0 |
| Industrial Affected | 0.0 |
| Residences Affected | 0.0 |
| Num Persons Hosp Not Ovnght | 0.0 |
| Num Injured Treated By Emt | 0.0 |
| Num Resident Building Affctd | 0.0 |
| Num Business Building Affctd | 1.0 |
| Accident Psig | 57.0 |
| Normal Psig | 57.0 |
| Mop Psig | 60.0 |
| Mop Cfr Section | 192.619(A)(2) View CFR 49 §192 |
| Maop Established Date | 1994-03-25 00:00:00 |
| Accident Pressure | Pressure Did Not Exceed Maop |
| Gas Odorized System Type | Drip |
| Gas Odorized Lvl Not Msrd Ind | Yes |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | No |
| Accident Identifier | Notification From Emergency Responder |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | The incident was the result of damage from a lawwnmower breaking the service regulator on the riser resulting in a leak. No control room actions resulted in the incident. |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Other Outside Force Damage |
| Cause Details | Damage By Car, Truck, Or Other Motorized Vehicle/equipment Not Engaged In Excavation |
| Outside Force Type | Damage By Car, Truck, Or Other Motorized Vehicle/equipment Not Engaged In Excavation |
| Vehicle Subtype | Third Party |
| Driver Issued Citation Ind | No |
| Driver In Control Ind | Unknown |
| Estimated Speed | Unknown |
| Vehicle Type | Motorcycle/atv |
| Vehicle Travel From | Off-Road |
| Vehicle Travel Distance Ft | 0 |
| Protections Installed Ind | No |
| Preparer Name | K**** G***** |
| Preparer Title | Manager Of Technical Services |
| Preparer Email | K******@s********.com |
| Preparer Telephone | 203-795-7767 |
| Preparer Fax | 203-795-7784 |
| Local Contact Name | J** M****** |
| Local Contact Email | J*******@s********.com |
| Local Contact Telephone | 203-650-7665 |
| Authorizer Name | A* L******* |
| Authorizer Title | Vice President |
| Authorizer Telephone | 203-257-5855 |
| Authorizer Email | A**********@a*******.com |
| Narrative | At 08:59 am june 7, 2021, scg received a call from the milford fire department regarding a gas fire involving a vehicle at 500 bic drive building #4 in milford. Scg first responders were informed that a commercial type lawn mower had struck the gas service regulator to the address resulting in a gas leak and fire. The fire department reported that approximately 50 occupants of the building were evacuated. The fire was extinguished by the milford fire department. The gas was shut off to the building by scg. The operator of the lawnmower sustained burns from the gas fire, and was taken to the hospital. Scg has learned that the operator of the lawnmower died of his injuries on july 2, 2021. This supplemental report updates the number of fatalities from "0" to "1" to reflect the death of the lawnmower operator. |
External Resources