GD incident on 2021-02-02 — PA

Operator
Ugi Utilities, Inc
Cause
Other Outside Force Damage
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$300
Incident datetime
2021-02-02 13:45
Report number
Location
PA, LEBANON
Narrative
At approximately 13:40 on february 2, 2021, the ugi call center received an inside odor call at 912 cumberland street, lebanon. Ugi dispatched the closest available qualified person to that location, arriving at 13:51. At approximately 13:53, there was a low-level explosion at 908 cumberland street. There were no injuries but the building sustained minor damage. The situation was made safe by closing the valve below the regulator inside the building. Only one customer was out of service at 908 cumberland street. Ugi conducted a full leak investigation with no leaks found. The basement of the building extended under the sidewalk. The regulator was located at the front wall of the building in the basement, placing it under the sidewalk. The vent pipe extended from the front wall of the basement to the fa�ade of the building through the sidewalk to the outside. A contractor operating a snowblower struck the above ground vent pipe at the front wall of the building. The force of the contact drove the pipe down through the concrete sidewalk, which cracked the regulator body and allowed gas to leak into the structure.
Detailed record list
Occurred At
2021-02-02 13:45:00
Year
2021
Report Received Date
2021-03-04 00:00:00
Iyear
2021.0
Report Number
20210025.0
Supplemental Number
34951.0
Report Type
Original Final
Operator Id
Name
Ugi Utilities, Inc
Operator Street Address
1 Ugi Drive
Operator City Name
Denver
Operator State Abbreviation
PA
Operator Postal Code
17517
Local Datetime
2021-02-02 14:25:00
Time Zone
Eastern
Daylight Savings Ind
No
Location Street Address
908 Cumberland Street
Location City Name
Lebanon
Location County Name
Lebanon
Location State Abbreviation
PA
Location Postal Code
17042
Location Latitude
Location Longitude
Flow Cont Meter Reg Ind
Yes
Nrc Rpt Datetime
2021-02-02 15:28:00
Nrc Rpt Num
Additional Nrc Report Numbers
1297357
Commodity Released Type
Natural Gas
Unintentional Release
1.8
Intentional Release
0.0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Ignite Ind
Yes
Ignite Datetime
2021-02-02 13:53:00
How Extinguished
Allowed To Burn Out
Gas Consumed By Fire In Mcf
1
Explode Ind
Yes
Num Pub Evacuated
20.0
Incident Identified Datetime
2021-02-02 13:45:00
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Initial Responder Com Datetime
2021-02-02 13:55:00
On Site Datetime
2021-02-02 13:51:00
Federal
No
Location Type
Private Property
Incident Area Type
Aboveground
Incident Area Subtype
Other
Incident Area Details
Reg Vent Pipe Extending Thru Sidewalk
Crossing
No
Pipe Facility Type
Investor Owned
System Part Involved
Inside Meter/regulator Set
Installation Year
2017.0
Customer Type
Non-Residential With Meter Capacity Less Than 1,000 Scfh
Was Efv Installed Before Ind
Yes
Evf Activation Ind
No
Curb Valve Inst Before Inc Ind
Yes
Material Involved
Other
Material Details
Regulator
Release Type
Leak
Leak Type
Crack
Class Location Type
Class 3 Location
Est Cost Oper Paid
64000.0
Est Cost Prop Damage
300.0
Est Cost Emergency
4864.0
Est Cost Other
0.0
Est Cost Other Details
None
Gas Cost In Mcf
2.75
Est Cost Unintentional Release
5.0
Est Cost Intentional Release
0.0
Prpty
69169.0
Commercial Affected
1.0
Industrial Affected
0.0
Residences Affected
0.0
Num Persons Hosp Not Ovnght
0.0
Num Injured Treated By Emt
0.0
Num Resident Building Affctd
0.0
Num Business Building Affctd
4.0
Accident Psig
51.0
Normal Psig
56.0
Mop Psig
60.0
Mop Cfr Section
192.619(A)(2)
Maop Established Date
2017-08-24 00:00:00
Accident Pressure
Pressure Did Not Exceed Maop
Gas Odorized System Type
Injection Pump
Gas Odorized Level
0.5
Scada In Place Ind
No
Accident Identifier
Notification From Public
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind
Yes
Num Employees Tested
1
Num Employees Failed
0
Contractor Drug Test Ind
No
Cause
Other Outside Force Damage
Cause Details
Other Outside Force Damage
Outside Force Type
Other Outside Force Damage
Osf Other Details
Regulator Vent Pipe Was Struck By A Snowblower
Preparer Name
R**** H***
Preparer Title
Engineer Ii - Standards
Preparer Email
R****@u**.com
Preparer Telephone
484-332-8402
Authorizer Name
P***** J*****
Authorizer Title
Vp Engoneering
Authorizer Telephone
484-524-5508
Authorizer Email
P******@u**.com
Narrative
At approximately 13:40 on february 2, 2021, the ugi call center received an inside odor call at 912 cumberland street, lebanon. Ugi dispatched the closest available qualified person to that location, arriving at 13:51. At approximately 13:53, there was a low-level explosion at 908 cumberland street. There were no injuries but the building sustained minor damage. The situation was made safe by closing the valve below the regulator inside the building. Only one customer was out of service at 908 cumberland street. Ugi conducted a full leak investigation with no leaks found. The basement of the building extended under the sidewalk. The regulator was located at the front wall of the building in the basement, placing it under the sidewalk. The vent pipe extended from the front wall of the basement to the fa�ade of the building through the sidewalk to the outside. A contractor operating a snowblower struck the above ground vent pipe at the front wall of the building. The force of the contact drove the pipe down through the concrete sidewalk, which cracked the regulator body and allowed gas to leak into the structure.
Occurred At 2021-02-02 13:45:00
Year 2021
Report Received Date 2021-03-04 00:00:00
Iyear 2021.0
Report Number 20210025.0
Supplemental Number 34951.0
Report Type Original Final
Operator Id 20010 PHMSA Enforcement
Name Ugi Utilities, Inc
Operator Street Address 1 Ugi Drive
Operator City Name Denver
Operator State Abbreviation PA
Operator Postal Code 17517
Local Datetime 2021-02-02 14:25:00
Time Zone Eastern
Daylight Savings Ind No
Location Street Address 908 Cumberland Street
Location City Name Lebanon
Location County Name Lebanon
Location State Abbreviation PA
Location Postal Code 17042
Location Latitude 40.33907 Google Maps OpenStreetMap
Location Longitude -76.42664 Google Maps OpenStreetMap
Flow Cont Meter Reg Ind Yes
Nrc Rpt Datetime 2021-02-02 15:28:00
Nrc Rpt Num 1297221 NRC Report How to search
Additional Nrc Report Numbers 1297357
Commodity Released Type Natural Gas
Unintentional Release 1.8
Intentional Release 0.0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Ignite Ind Yes
Ignite Datetime 2021-02-02 13:53:00
How Extinguished Allowed To Burn Out
Gas Consumed By Fire In Mcf 1
Explode Ind Yes
Num Pub Evacuated 20.0
Incident Identified Datetime 2021-02-02 13:45:00
Communication State Fed Ind Yes
Party Initiated Communication Operator
Initial Responder Com Datetime 2021-02-02 13:55:00
On Site Datetime 2021-02-02 13:51:00
Federal No
Location Type Private Property
Incident Area Type Aboveground
Incident Area Subtype Other
Incident Area Details Reg Vent Pipe Extending Thru Sidewalk
Crossing No
Pipe Facility Type Investor Owned
System Part Involved Inside Meter/regulator Set
Installation Year 2017.0
Customer Type Non-Residential With Meter Capacity Less Than 1,000 Scfh
Was Efv Installed Before Ind Yes
Evf Activation Ind No
Curb Valve Inst Before Inc Ind Yes
Material Involved Other
Material Details Regulator
Release Type Leak
Leak Type Crack
Class Location Type Class 3 Location
Est Cost Oper Paid 64000.0
Est Cost Prop Damage 300.0
Est Cost Emergency 4864.0
Est Cost Other 0.0
Est Cost Other Details None
Gas Cost In Mcf 2.75
Est Cost Unintentional Release 5.0
Est Cost Intentional Release 0.0
Prpty 69169.0
Commercial Affected 1.0
Industrial Affected 0.0
Residences Affected 0.0
Num Persons Hosp Not Ovnght 0.0
Num Injured Treated By Emt 0.0
Num Resident Building Affctd 0.0
Num Business Building Affctd 4.0
Accident Psig 51.0
Normal Psig 56.0
Mop Psig 60.0
Mop Cfr Section 192.619(A)(2) View CFR 49 §192
Maop Established Date 2017-08-24 00:00:00
Accident Pressure Pressure Did Not Exceed Maop
Gas Odorized System Type Injection Pump
Gas Odorized Level 0.5
Scada In Place Ind No
Accident Identifier Notification From Public
Investigation Status No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind Yes
Num Employees Tested 1
Num Employees Failed 0
Contractor Drug Test Ind No
Cause Other Outside Force Damage
Cause Details Other Outside Force Damage
Outside Force Type Other Outside Force Damage
Osf Other Details Regulator Vent Pipe Was Struck By A Snowblower
Preparer Name R**** H***
Preparer Title Engineer Ii - Standards
Preparer Email R****@u**.com
Preparer Telephone 484-332-8402
Authorizer Name P***** J*****
Authorizer Title Vp Engoneering
Authorizer Telephone 484-524-5508
Authorizer Email P******@u**.com
Narrative At approximately 13:40 on february 2, 2021, the ugi call center received an inside odor call at 912 cumberland street, lebanon. Ugi dispatched the closest available qualified person to that location, arriving at 13:51. At approximately 13:53, there was a low-level explosion at 908 cumberland street. There were no injuries but the building sustained minor damage. The situation was made safe by closing the valve below the regulator inside the building. Only one customer was out of service at 908 cumberland street. Ugi conducted a full leak investigation with no leaks found. The basement of the building extended under the sidewalk. The regulator was located at the front wall of the building in the basement, placing it under the sidewalk. The vent pipe extended from the front wall of the basement to the fa�ade of the building through the sidewalk to the outside. A contractor operating a snowblower struck the above ground vent pipe at the front wall of the building. The force of the contact drove the pipe down through the concrete sidewalk, which cracked the regulator body and allowed gas to leak into the structure.