Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2020-10-18 — TX
Operator
Sunoco Partners Marketing & Terminals Lp
Cause
Corrosion Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$100
Incident datetime
2020-10-18 07:30
Report number
Location
TX
Narrative
On 10/18/20 at 7:30am, a contractor located oil leaking from the bottom of the t326 valve on the texaco manifold. Upon inspection by the duty foreman, it was noted that a plug was leaking at the bottom of the valve, approximately 2 barrels was released. Operations blocked in the line and rerouted the flow of crude. Operations put a suction on the line to stop the leak. A vacuum truck was called to remove the oil from under the valve. It was found that the reducer plug had failed due to corrosion. A new plug was installed on the reducer. Remediation of the soil around the spill was completed on site.
Detailed record list
Report Received Date
2020-11-12 00:00:00
Iyear
2020
Report Number
20200307
Supplemental Number
34529
Report Type
Original Final
Operator Id
39706
Name
Sunoco Partners Marketing & Terminals Lp
Operator Street Address
1300 Main Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2020-10-18 07:30:00
Location Latitude
29.9950861
Location Longitude
-93.992647
Commodity Released Type
Crude Oil
Unintentional Release Bbls
2
Recovered Bbls
2
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
Incident Identified Datetime
2020-10-18 07:30:00
System Part Involved
Onshore Terminal/tank Farm Equipment And Piping
On Off Shore
Onshore
Shutdown Due Accident Ind
No
Shutdown Explain
Crude Was Rerouted
On Site Datetime
2020-10-18 07:30:00
Nrc Rpt Num
Nrc Notification Not Required
Ignite Ind
No
Explode Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Nederland Terminal
Segment Name
Texaco Manifold Valve T326
Onshore State Abbreviation
Tx
Onshore Postal Code
77627
Onshore City Name
Nederland
Onshore County Name
Jefferson
Designated Location
Survey Station No.
Designated Name
0+00
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Valve
Valve Type
Auxiliary Or Other Valve
Installation Year
2017
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Connection Failure
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
Yes
High Pop Ind
Yes
High Pop Yes No
No
Est Cost Oper Paid
0
Est Cost Gas Released
100
Est Cost Prop Damage
100
Est Cost Emergency
300
Est Cost Environmental
500
Est Cost Other
0
Prpty
1000
Accident Psig
80
Mop Psig
285
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
A review of the accident determined that there were no control room actions that contributed to the event.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
Internal Corrosion
Internal External
Internal Corrosion
Int Visual Exam Results
General Corrosion
Int Water Acid Ind
Yes
Int Field Exam Basis Ind
Yes
Int Other Loc Ind
Yes
Corrosion Location Details
Reducer Plug
Corrosion Inhibitors
Yes
Corrosion Lining
No
Cleaning Dewatering
Not Applicable - Not Mainline Pipe
Corrosion Coupons
Not Applicable - Not Mainline Pipe
Preparer Name
N****** P********
Preparer Title
Dot Compliance Specialist
Preparer Email
N****************@e*************.com
Preparer Telephone
713-989-4527
Prepared Date
2020-11-12 00:00:00
Authorizer Name
C**** K*****
Authorizer Telephone
719-989-7077
Authorizer Title
Manager - Regulatory Compliance
Authorizer Email
C***********@e*************.com
Narrative
On 10/18/20 at 7:30am, a contractor located oil leaking from the bottom of the t326 valve on the texaco manifold. Upon inspection by the duty foreman, it was noted that a plug was leaking at the bottom of the valve, approximately 2 barrels was released. Operations blocked in the line and rerouted the flow of crude. Operations put a suction on the line to stop the leak. A vacuum truck was called to remove the oil from under the valve. It was found that the reducer plug had failed due to corrosion. A new plug was installed on the reducer. Remediation of the soil around the spill was completed on site.
| Report Received Date | 2020-11-12 00:00:00 |
|---|---|
| Iyear | 2020 |
| Report Number | 20200307 |
| Supplemental Number | 34529 |
| Report Type | Original Final |
| Operator Id | 39706 PHMSA Enforcement |
| Name | Sunoco Partners Marketing & Terminals Lp |
| Operator Street Address | 1300 Main Street |
| Operator City Name | Houston |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77002 |
| Local Datetime | 2020-10-18 07:30:00 |
| Location Latitude | 29.9950861 Google Maps OpenStreetMap |
| Location Longitude | -93.992647 Google Maps OpenStreetMap |
| Commodity Released Type | Crude Oil |
| Unintentional Release Bbls | 2 |
| Recovered Bbls | 2 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Local Operating Personnel, Including Contractors |
| Operator Type | Operator Employee |
| Incident Identified Datetime | 2020-10-18 07:30:00 |
| System Part Involved | Onshore Terminal/tank Farm Equipment And Piping |
| On Off Shore | Onshore |
| Shutdown Due Accident Ind | No |
| Shutdown Explain | Crude Was Rerouted |
| On Site Datetime | 2020-10-18 07:30:00 |
| Nrc Rpt Num | Nrc Notification Not Required NRC Report How to search |
| Ignite Ind | No |
| Explode Ind | No |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Nederland Terminal |
| Segment Name | Texaco Manifold Valve T326 |
| Onshore State Abbreviation | Tx |
| Onshore Postal Code | 77627 |
| Onshore City Name | Nederland |
| Onshore County Name | Jefferson |
| Designated Location | Survey Station No. |
| Designated Name | 0+00 |
| Federal | No |
| Location Type | Totally Contained On Operator-Controlled Property |
| Incident Area Type | Aboveground |
| Incident Area Subtype | Typical Aboveground Facility Piping Or Appurtenance |
| Crossing | No |
| Pipe Facility Type | Interstate |
| Item Involved | Valve |
| Valve Type | Auxiliary Or Other Valve |
| Installation Year | 2017 |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Connection Failure |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | No |
| Remediation Ind | Yes |
| Soil Remed Ind | Yes |
| Water Contam Ind | No |
| Could Be Hca | No |
| Commodity Reached Hca | Yes |
| High Pop Ind | Yes |
| High Pop Yes No | No |
| Est Cost Oper Paid | 0 |
| Est Cost Gas Released | 100 |
| Est Cost Prop Damage | 100 |
| Est Cost Emergency | 300 |
| Est Cost Environmental | 500 |
| Est Cost Other | 0 |
| Prpty | 1000 |
| Accident Psig | 80 |
| Mop Psig | 285 |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | No |
| Cpm In Place Ind | Yes |
| Cpm Operating Ind | Yes |
| Cpm Functional Ind | Yes |
| Cpm Detection Ind | No |
| Cpm Conf Ind | No |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | A review of the accident determined that there were no control room actions that contributed to the event. |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Corrosion Failure |
| Cause Details | Internal Corrosion |
| Internal External | Internal Corrosion |
| Int Visual Exam Results | General Corrosion |
| Int Water Acid Ind | Yes |
| Int Field Exam Basis Ind | Yes |
| Int Other Loc Ind | Yes |
| Corrosion Location Details | Reducer Plug |
| Corrosion Inhibitors | Yes |
| Corrosion Lining | No |
| Cleaning Dewatering | Not Applicable - Not Mainline Pipe |
| Corrosion Coupons | Not Applicable - Not Mainline Pipe |
| Preparer Name | N****** P******** |
| Preparer Title | Dot Compliance Specialist |
| Preparer Email | N****************@e*************.com |
| Preparer Telephone | 713-989-4527 |
| Prepared Date | 2020-11-12 00:00:00 |
| Authorizer Name | C**** K***** |
| Authorizer Telephone | 719-989-7077 |
| Authorizer Title | Manager - Regulatory Compliance |
| Authorizer Email | C***********@e*************.com |
| Narrative | On 10/18/20 at 7:30am, a contractor located oil leaking from the bottom of the t326 valve on the texaco manifold. Upon inspection by the duty foreman, it was noted that a plug was leaking at the bottom of the valve, approximately 2 barrels was released. Operations blocked in the line and rerouted the flow of crude. Operations put a suction on the line to stop the leak. A vacuum truck was called to remove the oil from under the valve. It was found that the reducer plug had failed due to corrosion. A new plug was installed on the reducer. Remediation of the soil around the spill was completed on site. |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company
All rights reserved. Copyright © by ClearPHMSA