Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2020-09-02 — TX
Operator
Plains Pipeline, L.p.
Cause
Equipment Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$7,000
Incident datetime
2020-09-02 12:28
Report number
Location
TX
Narrative
Approximately 279 barrels of crude oil were released from a tank mixer at wolfbone ranch station. The date and time of the release (part a q4) is indicative of the earliest possible time the release could have started, as it was the last time the station had been visited and confirmed crude oil was not being released. The national response center (nrc) was contacted on the basis of estimated costs exceeding $50,000 (initial nrc report #: 1286874, and 48-hour nrc follow-up report #: 1287079). The cause of the incident was determined to be equipment failure of the seal as a result of a manufacturing defect on the bolts and bearings. To prevent future releases, plains has replaced the seal, bolts, and bearings as recommended by the manufacturer, and is conducting further investigations to determine if other mixers of this brand and model require new bolts and bearings. 09/24/2024 - updated by PHMSA per operator approval.
Detailed record list
Report Received Date
2020-10-02 00:00:00
Iyear
2020
Report Number
20200269
Supplemental Number
34331
Report Type
Original Final
Operator Id
Name
Plains Pipeline, L.p.
Operator Street Address
333 Clay Street, Suite 1900
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2020-09-02 07:00:00
Location Latitude
31.279649
Location Longitude
-103.370868
Commodity Released Type
Crude Oil
Unintentional Release Bbls
279
Recovered Bbls
190
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
Incident Identified Datetime
2020-09-02 12:28:00
System Part Involved
Onshore Breakout Tank Or Storage Vessel, Including Attached Appurtenances
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2020-09-02 12:30:00
Restart Datetime
2020-09-02 16:40:00
On Site Datetime
2020-09-02 12:28:00
Nrc Rpt Datetime
2020-09-09 10:40:00
Nrc Rpt Num
1286874
Ignite Ind
No
Explode Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Wolfbone Ranch Station
Segment Name
Wolfbone Ranch Station Tank Mixer
Onshore State Abbreviation
Tx
Onshore Postal Code
79772
Onshore City Name
Pecos
Onshore County Name
Reeves
Designated Location
Milepost/valve Station
Designated Name
0+00
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Tank/vessel
Tank Vessel Subtype
Mixer
Tank Type
Atmospheric
Item Involved Details
Tank Mixer
Installation Year
2015
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Seal Or Packing
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
2670
Est Cost Prop Damage
7000
Est Cost Emergency
68000
Est Cost Environmental
0
Est Cost Other
0
Prpty
77670
Accident Psig
7
Mop Psig
285
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
Yes, specify investigation result(s): (select all that apply)
Invest Schedule Ind
Yes
Invest No Control Room Ind
Yes
Invest No Controller Ind
Yes
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Equipment Failure
Cause Details
Non-Threaded Connection Failure
Eq Failure Type
Non-Threaded Connection Failure
Other Non Threaded Ind
Seal (Not Pump Seal) Or Packing
Additional Defect Ind
Yes
Eq Additional Other Ind
Yes
Eq Additional Other Details
Bolts And Bearings
Preparer Name
N****** G*******
Preparer Title
Hse Compliance Specialist
Preparer Email
N*********@p****.com
Preparer Telephone
7136464376
Prepared Date
2020-10-02 00:00:00
Authorizer Name
N***** G*****
Authorizer Telephone
7136464336
Authorizer Title
Hse Compliance Director
Authorizer Email
N******@p****.com
Narrative
Approximately 279 barrels of crude oil were released from a tank mixer at wolfbone ranch station. The date and time of the release (part a q4) is indicative of the earliest possible time the release could have started, as it was the last time the station had been visited and confirmed crude oil was not being released. The national response center (nrc) was contacted on the basis of estimated costs exceeding $50,000 (initial nrc report #: 1286874, and 48-hour nrc follow-up report #: 1287079). The cause of the incident was determined to be equipment failure of the seal as a result of a manufacturing defect on the bolts and bearings. To prevent future releases, plains has replaced the seal, bolts, and bearings as recommended by the manufacturer, and is conducting further investigations to determine if other mixers of this brand and model require new bolts and bearings. 09/24/2024 - updated by PHMSA per operator approval.
| Report Received Date | 2020-10-02 00:00:00 |
|---|---|
| Iyear | 2020 |
| Report Number | 20200269 |
| Supplemental Number | 34331 |
| Report Type | Original Final |
| Operator Id | 300 PHMSA Enforcement |
| Name | Plains Pipeline, L.p. |
| Operator Street Address | 333 Clay Street, Suite 1900 |
| Operator City Name | Houston |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77002 |
| Local Datetime | 2020-09-02 07:00:00 |
| Location Latitude | 31.279649 Google Maps OpenStreetMap |
| Location Longitude | -103.370868 Google Maps OpenStreetMap |
| Commodity Released Type | Crude Oil |
| Unintentional Release Bbls | 279 |
| Recovered Bbls | 190 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Local Operating Personnel, Including Contractors |
| Operator Type | Operator Employee |
| Incident Identified Datetime | 2020-09-02 12:28:00 |
| System Part Involved | Onshore Breakout Tank Or Storage Vessel, Including Attached Appurtenances |
| On Off Shore | Onshore |
| Shutdown Due Accident Ind | Yes |
| Shutdown Datetime | 2020-09-02 12:30:00 |
| Restart Datetime | 2020-09-02 16:40:00 |
| On Site Datetime | 2020-09-02 12:28:00 |
| Nrc Rpt Datetime | 2020-09-09 10:40:00 |
| Nrc Rpt Num | 1286874 NRC Report How to search |
| Ignite Ind | No |
| Explode Ind | No |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Wolfbone Ranch Station |
| Segment Name | Wolfbone Ranch Station Tank Mixer |
| Onshore State Abbreviation | Tx |
| Onshore Postal Code | 79772 |
| Onshore City Name | Pecos |
| Onshore County Name | Reeves |
| Designated Location | Milepost/valve Station |
| Designated Name | 0+00 |
| Federal | No |
| Location Type | Totally Contained On Operator-Controlled Property |
| Incident Area Type | Aboveground |
| Incident Area Subtype | Typical Aboveground Facility Piping Or Appurtenance |
| Crossing | No |
| Pipe Facility Type | Intrastate |
| Item Involved | Tank/vessel |
| Tank Vessel Subtype | Mixer |
| Tank Type | Atmospheric |
| Item Involved Details | Tank Mixer |
| Installation Year | 2015 |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Seal Or Packing |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | No |
| Remediation Ind | No |
| Water Contam Ind | No |
| Could Be Hca | No |
| Commodity Reached Hca | No |
| Est Cost Oper Paid | 0 |
| Est Cost Gas Released | 2670 |
| Est Cost Prop Damage | 7000 |
| Est Cost Emergency | 68000 |
| Est Cost Environmental | 0 |
| Est Cost Other | 0 |
| Prpty | 77670 |
| Accident Psig | 7 |
| Mop Psig | 285 |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | No |
| Cpm In Place Ind | No |
| Investigation Status | Yes, specify investigation result(s): (select all that apply) |
| Invest Schedule Ind | Yes |
| Invest No Control Room Ind | Yes |
| Invest No Controller Ind | Yes |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Equipment Failure |
| Cause Details | Non-Threaded Connection Failure |
| Eq Failure Type | Non-Threaded Connection Failure |
| Other Non Threaded Ind | Seal (Not Pump Seal) Or Packing |
| Additional Defect Ind | Yes |
| Eq Additional Other Ind | Yes |
| Eq Additional Other Details | Bolts And Bearings |
| Preparer Name | N****** G******* |
| Preparer Title | Hse Compliance Specialist |
| Preparer Email | N*********@p****.com |
| Preparer Telephone | 7136464376 |
| Prepared Date | 2020-10-02 00:00:00 |
| Authorizer Name | N***** G***** |
| Authorizer Telephone | 7136464336 |
| Authorizer Title | Hse Compliance Director |
| Authorizer Email | N******@p****.com |
| Narrative | Approximately 279 barrels of crude oil were released from a tank mixer at wolfbone ranch station. The date and time of the release (part a q4) is indicative of the earliest possible time the release could have started, as it was the last time the station had been visited and confirmed crude oil was not being released. The national response center (nrc) was contacted on the basis of estimated costs exceeding $50,000 (initial nrc report #: 1286874, and 48-hour nrc follow-up report #: 1287079). The cause of the incident was determined to be equipment failure of the seal as a result of a manufacturing defect on the bolts and bearings. To prevent future releases, plains has replaced the seal, bolts, and bearings as recommended by the manufacturer, and is conducting further investigations to determine if other mixers of this brand and model require new bolts and bearings. 09/24/2024 - updated by PHMSA per operator approval. |