Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2020-08-21 — TX
Operator
Phillips 66 Pipeline Llc
Cause
Other Outside Force Damage
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$10,000
Incident datetime
2020-08-21 21:50
Report number
Location
TX
Narrative
On the evening of august 21st, 2020, a landowner and his son were shooting targets in the vicinity of the line o crude pipeline between mp 196 and mp 197 during which time an errant round is suspected to have contacted the pipeline resulting in a release of approximately 30 bbls. The pipeline was repaired with a clamp and returned to service the following day, 8-22. 2020-9-14 - updated per PHMSA request - the answer to c-6 was initially reported as "crack" and was changed to "mechanical puncture". Once the selection of "mechanical puncture" is selected, the report then asks for axial and circumferential measurements. Neither filed will accept a number smaller than 0.50 inches. The actual measurements are 0.25 axial by 0.5 circumferential. The stray round that impacted the pipeline was reported to have had bounced off of a steel target. The landowner's shooting table and target were relocated to prevent a similar incident and lessons learned are being share company wide. The landowner originally notified another pipeline operator in the area. Upon the 3rd party pipeline operators' arrival on site and observations, they contacted p66. The pipeline was shutdown per part a on 8-21-2020 at 20:35, upon receipt of phone call notification from 3rd party pipeline operator. Scada data helped confirm the release at 21:44. Initial nrc notification report #1285235. 48 hr nrc update call placed on 8-23-2020 @16:46 est. Nrc did not issue a new/updated report so a 2nd 48 hr update call was placed on 8-24-2020, report # 1285463.
Detailed record list
Report Received Date
2020-09-10 00:00:00
Iyear
2020
Report Number
20200249
Supplemental Number
34270
Report Type
Supplemental Final
Operator Id
31684
Name
Phillips 66 Pipeline Llc
Operator Street Address
2331 Citywest Blvd
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77042
Local Datetime
2020-08-21 20:15:00
Location Latitude
35.742355
Location Longitude
-98.025499
Commodity Released Type
Crude Oil
Unintentional Release Bbls
30
Recovered Bbls
30
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Other
Accident Details
3rd Party Pipeline Operator In The Area
Incident Identified Datetime
2020-08-21 21:50:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2020-08-21 20:35:00
Restart Datetime
2020-08-22 16:05:00
On Site Datetime
2020-08-21 21:50:00
Nrc Rpt Datetime
2020-08-21 22:50:00
Nrc Rpt Num
1285235
Ignite Ind
No
Explode Ind
No
Upstream Valve Type Ind
Automatic
Downstream Valve Type Ind
Automatic
Num Pub Evacuated
0
Pipe Fac Name
Lo-01
Segment Name
Okarche To Geary
Onshore State Abbreviation
Ok
Onshore Postal Code
73762
Onshore City Name
Not Within A Municipality
Onshore County Name
Kingfisher
Designated Location
Milepost/valve Station
Designated Name
196
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Aboveground
Incident Area Subtype
In Or Spanning An Open Ditch
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pipe
Pipe Type
Pipe Body
Pipe Diameter
10
Pipe Wall Thickness
0.203
Pipe Smys
42000
Pipe Specification
Api-5lx
Pipe Seam Type
Erw - Low Frequency
Pipe Manufacturer
Republic
Pipe Coating Type
Coal Tar
Installation Year
1951
Manufactured Year
1951
Material Involved
Carbon Steel
Release Type
Mechanical Puncture
Puncture Axial
0.5
Puncture Circum
0.5
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
Yes
Surface Contam Ind
Yes
Amount Released
13
Rel Water Name
Unnamed Tributary
Could Be Hca
Yes
Commodity Reached Hca
No
Est Cost Oper Paid
10
Est Cost Gas Released
300
Est Cost Prop Damage
10000
Est Cost Emergency
36000
Est Cost Environmental
3000
Est Cost Other
0
Prpty
49310
Accident Psig
280
Mop Psig
1142
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
Yes
Exceed Restriction Ind
No
Phmsa Restriction Ind
Phmsa
Length Segment Isolated
118509
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
Yes
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
Yes
Investigation Status
Yes, specify investigation result(s): (select all that apply)
Invest Schedule Ind
Yes
Invest No Control Room Ind
Yes
Invest No Controller Ind
Yes
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Other Outside Force Damage
Cause Details
Other Outside Force Damage
Outside Force Type
Other Outside Force Damage
Osf Other Details
Errant Gun Shot Ricochet From Steel Target
Preparer Name
J*** B*********
Preparer Title
Dot Coordinator
Preparer Email
J****************@p**.com
Preparer Telephone
580-767-4206
Prepared Date
2020-09-14 00:00:00
Authorizer Name
T*** F****
Authorizer Telephone
832-765-1632
Authorizer Title
Dot Director
Authorizer Email
T***********@p**.com
Narrative
O*********************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************@16:46 est. ************************************************************************************************************.
| Report Received Date | 2020-09-10 00:00:00 |
|---|---|
| Iyear | 2020 |
| Report Number | 20200249 |
| Supplemental Number | 34270 |
| Report Type | Supplemental Final |
| Operator Id | 31684 PHMSA Enforcement |
| Name | Phillips 66 Pipeline Llc |
| Operator Street Address | 2331 Citywest Blvd |
| Operator City Name | Houston |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77042 |
| Local Datetime | 2020-08-21 20:15:00 |
| Location Latitude | 35.742355 Google Maps OpenStreetMap |
| Location Longitude | -98.025499 Google Maps OpenStreetMap |
| Commodity Released Type | Crude Oil |
| Unintentional Release Bbls | 30 |
| Recovered Bbls | 30 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Other |
| Accident Details | 3rd Party Pipeline Operator In The Area |
| Incident Identified Datetime | 2020-08-21 21:50:00 |
| System Part Involved | Onshore Pipeline, Including Valve Sites |
| On Off Shore | Onshore |
| Shutdown Due Accident Ind | Yes |
| Shutdown Datetime | 2020-08-21 20:35:00 |
| Restart Datetime | 2020-08-22 16:05:00 |
| On Site Datetime | 2020-08-21 21:50:00 |
| Nrc Rpt Datetime | 2020-08-21 22:50:00 |
| Nrc Rpt Num | 1285235 NRC Report How to search |
| Ignite Ind | No |
| Explode Ind | No |
| Upstream Valve Type Ind | Automatic |
| Downstream Valve Type Ind | Automatic |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Lo-01 |
| Segment Name | Okarche To Geary |
| Onshore State Abbreviation | Ok |
| Onshore Postal Code | 73762 |
| Onshore City Name | Not Within A Municipality |
| Onshore County Name | Kingfisher |
| Designated Location | Milepost/valve Station |
| Designated Name | 196 |
| Federal | No |
| Location Type | Pipeline Right-Of-Way |
| Incident Area Type | Aboveground |
| Incident Area Subtype | In Or Spanning An Open Ditch |
| Crossing | No |
| Pipe Facility Type | Interstate |
| Item Involved | Pipe |
| Pipe Type | Pipe Body |
| Pipe Diameter | 10 |
| Pipe Wall Thickness | 0.203 |
| Pipe Smys | 42000 |
| Pipe Specification | Api-5lx |
| Pipe Seam Type | Erw - Low Frequency |
| Pipe Manufacturer | Republic |
| Pipe Coating Type | Coal Tar |
| Installation Year | 1951 |
| Manufactured Year | 1951 |
| Material Involved | Carbon Steel |
| Release Type | Mechanical Puncture |
| Puncture Axial | 0.5 |
| Puncture Circum | 0.5 |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | No |
| Remediation Ind | Yes |
| Soil Remed Ind | Yes |
| Water Contam Ind | Yes |
| Surface Contam Ind | Yes |
| Amount Released | 13 |
| Rel Water Name | Unnamed Tributary |
| Could Be Hca | Yes |
| Commodity Reached Hca | No |
| Est Cost Oper Paid | 10 |
| Est Cost Gas Released | 300 |
| Est Cost Prop Damage | 10000 |
| Est Cost Emergency | 36000 |
| Est Cost Environmental | 3000 |
| Est Cost Other | 0 |
| Prpty | 49310 |
| Accident Psig | 280 |
| Mop Psig | 1142 |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | Yes |
| Exceed Restriction Ind | No |
| Phmsa Restriction Ind | Phmsa |
| Length Segment Isolated | 118509 |
| Internal Inspection Ind | Yes |
| Operation Complications Ind | No |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | Yes |
| Cpm In Place Ind | Yes |
| Cpm Operating Ind | Yes |
| Cpm Functional Ind | Yes |
| Cpm Detection Ind | No |
| Cpm Conf Ind | Yes |
| Investigation Status | Yes, specify investigation result(s): (select all that apply) |
| Invest Schedule Ind | Yes |
| Invest No Control Room Ind | Yes |
| Invest No Controller Ind | Yes |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Other Outside Force Damage |
| Cause Details | Other Outside Force Damage |
| Outside Force Type | Other Outside Force Damage |
| Osf Other Details | Errant Gun Shot Ricochet From Steel Target |
| Preparer Name | J*** B********* |
| Preparer Title | Dot Coordinator |
| Preparer Email | J****************@p**.com |
| Preparer Telephone | 580-767-4206 |
| Prepared Date | 2020-09-14 00:00:00 |
| Authorizer Name | T*** F**** |
| Authorizer Telephone | 832-765-1632 |
| Authorizer Title | Dot Director |
| Authorizer Email | T***********@p**.com |
| Narrative | O*********************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************@16:46 est. ************************************************************************************************************. |
External Resources