HL incident on 2020-04-30 — TX
Operator
Enbridge Energy, Limited Partnership
Cause
Natural Force Damage
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$0
Incident datetime
2020-04-30 09:00
Report number
Location
TX
Narrative
On april 30, 2020 at 07:53 cdt, griffith terminal personnel notified the edmonton control center (ecc) of a suspicious odor and the terminal was shutdown. An investigation of the facility was initiated requiring all tanks to be climbed. It was determined that the odor originated from an open vent on tank 76 due to high water on the roof while it was at working bottoms. The remainder of the tanks were climbed in order to give ecc approval to restart the terminal. At approximately 09:00 cdt, a griffith terminal maintainer climbed tank 71 and discovered an active release on the tank roof. Following several heavy rains, the water on the external floating tank roof displaced the roof causing the pin holes on the top of the center tank legs to drop below the product level in the tank spilling oil onto the roof. The tank was isolated and locked out, and the approval to restart the terminal was given to ecc. Pipeline maintenance personnel were onsite and initiated cleanup of the tank roof. A triple filter system was installed on the roof drain to safely drain water from the roof. After cleanup was complete, tank 71 was returned to service.
Detailed record list
Report Received Date
2020-05-29 00:00:00
Iyear
2020
Report Number
20200151
Supplemental Number
33832
Report Type
Original Final
Operator Id
11169
Name
Enbridge Energy, Limited Partnership
Operator Street Address
915 N Eldridge Parkway, Suite 1100
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77079
Local Datetime
2020-04-30 07:53:00
Location Latitude
41.516896
Location Longitude
-87.450594
Commodity Released Type
Crude Oil
Unintentional Release Bbls
2.52
Recovered Bbls
2.52
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
Incident Identified Datetime
2020-04-30 09:00:00
System Part Involved
Onshore Breakout Tank Or Storage Vessel, Including Attached Appurtenances
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2020-04-30 07:58:00
Restart Datetime
2020-04-30 10:43:00
On Site Datetime
2020-04-30 07:53:00
Nrc Rpt Num
Nrc Notification Not Required
Ignite Ind
No
Explode Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Griffith Terminal
Segment Name
Tank 71
Onshore State Abbreviation
In
Onshore Postal Code
46319
Onshore City Name
Griffith
Onshore County Name
Lake
Designated Location
Milepost/valve Station
Designated Name
550
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Tank, Including Attached Appurtenances
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Tank/vessel
Tank Vessel Subtype
Roof/roof Seal
Tank Type
Atmospheric
Installation Year
1970
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Other
Leak Type Other
Water Weight On Floating Roof
Wildlife Impact Ind
No
Soil Contamination
No
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
Yes
High Pop Ind
Yes
High Pop Yes No
Yes
Usa Ecological Ind
Yes
Usa Ecological Yes No
Yes
Est Cost Oper Paid
0
Est Cost Gas Released
53
Est Cost Prop Damage
0
Est Cost Emergency
30000
Est Cost Environmental
0
Est Cost Other
0
Prpty
30053
Accident Psig
0
Mop Psig
45
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Lack of control center involvement
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Natural Force Damage
Cause Details
Heavy Rains/floods
Natural Force Type
Heavy Rains/floods
Heavy Rains Subtype
Other
Nf Other Details
Heavy Rains Caused Displacement Of The Product Under The External Floating Roof
Nf Extreme Weather Ind
No
Preparer Name
S**** S****
Preparer Title
Sr Compliance Analyst
Preparer Email
S**********@e*******.com
Preparer Telephone
715-395-3620
Prepared Date
2020-05-29 00:00:00
Authorizer Name
R** C*******
Authorizer Telephone
715-395-3619
Authorizer Title
Supervisor Us Pipeline Compliance
Authorizer Email
R***********@e*******.com
Narrative
On april 30, 2020 at 07:53 cdt, griffith terminal personnel notified the edmonton control center (ecc) of a suspicious odor and the terminal was shutdown. An investigation of the facility was initiated requiring all tanks to be climbed. It was determined that the odor originated from an open vent on tank 76 due to high water on the roof while it was at working bottoms. The remainder of the tanks were climbed in order to give ecc approval to restart the terminal. At approximately 09:00 cdt, a griffith terminal maintainer climbed tank 71 and discovered an active release on the tank roof. Following several heavy rains, the water on the external floating tank roof displaced the roof causing the pin holes on the top of the center tank legs to drop below the product level in the tank spilling oil onto the roof. The tank was isolated and locked out, and the approval to restart the terminal was given to ecc. Pipeline maintenance personnel were onsite and initiated cleanup of the tank roof. A triple filter system was installed on the roof drain to safely drain water from the roof. After cleanup was complete, tank 71 was returned to service.
| Report Received Date | 2020-05-29 00:00:00 |
|---|---|
| Iyear | 2020 |
| Report Number | 20200151 |
| Supplemental Number | 33832 |
| Report Type | Original Final |
| Operator Id | 11169 PHMSA Enforcement |
| Name | Enbridge Energy, Limited Partnership |
| Operator Street Address | 915 N Eldridge Parkway, Suite 1100 |
| Operator City Name | Houston |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77079 |
| Local Datetime | 2020-04-30 07:53:00 |
| Location Latitude | 41.516896 Google Maps OpenStreetMap |
| Location Longitude | -87.450594 Google Maps OpenStreetMap |
| Commodity Released Type | Crude Oil |
| Unintentional Release Bbls | 2.52 |
| Recovered Bbls | 2.52 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Local Operating Personnel, Including Contractors |
| Operator Type | Operator Employee |
| Incident Identified Datetime | 2020-04-30 09:00:00 |
| System Part Involved | Onshore Breakout Tank Or Storage Vessel, Including Attached Appurtenances |
| On Off Shore | Onshore |
| Shutdown Due Accident Ind | Yes |
| Shutdown Datetime | 2020-04-30 07:58:00 |
| Restart Datetime | 2020-04-30 10:43:00 |
| On Site Datetime | 2020-04-30 07:53:00 |
| Nrc Rpt Num | Nrc Notification Not Required NRC Report How to search |
| Ignite Ind | No |
| Explode Ind | No |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Griffith Terminal |
| Segment Name | Tank 71 |
| Onshore State Abbreviation | In |
| Onshore Postal Code | 46319 |
| Onshore City Name | Griffith |
| Onshore County Name | Lake |
| Designated Location | Milepost/valve Station |
| Designated Name | 550 |
| Federal | No |
| Location Type | Totally Contained On Operator-Controlled Property |
| Incident Area Type | Tank, Including Attached Appurtenances |
| Crossing | No |
| Pipe Facility Type | Interstate |
| Item Involved | Tank/vessel |
| Tank Vessel Subtype | Roof/roof Seal |
| Tank Type | Atmospheric |
| Installation Year | 1970 |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Other |
| Leak Type Other | Water Weight On Floating Roof |
| Wildlife Impact Ind | No |
| Soil Contamination | No |
| Long Term Assessment | No |
| Remediation Ind | No |
| Water Contam Ind | No |
| Could Be Hca | Yes |
| Commodity Reached Hca | Yes |
| High Pop Ind | Yes |
| High Pop Yes No | Yes |
| Usa Ecological Ind | Yes |
| Usa Ecological Yes No | Yes |
| Est Cost Oper Paid | 0 |
| Est Cost Gas Released | 53 |
| Est Cost Prop Damage | 0 |
| Est Cost Emergency | 30000 |
| Est Cost Environmental | 0 |
| Est Cost Other | 0 |
| Prpty | 30053 |
| Accident Psig | 0 |
| Mop Psig | 45 |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | No |
| Cpm In Place Ind | No |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | Lack of control center involvement |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Natural Force Damage |
| Cause Details | Heavy Rains/floods |
| Natural Force Type | Heavy Rains/floods |
| Heavy Rains Subtype | Other |
| Nf Other Details | Heavy Rains Caused Displacement Of The Product Under The External Floating Roof |
| Nf Extreme Weather Ind | No |
| Preparer Name | S**** S**** |
| Preparer Title | Sr Compliance Analyst |
| Preparer Email | S**********@e*******.com |
| Preparer Telephone | 715-395-3620 |
| Prepared Date | 2020-05-29 00:00:00 |
| Authorizer Name | R** C******* |
| Authorizer Telephone | 715-395-3619 |
| Authorizer Title | Supervisor Us Pipeline Compliance |
| Authorizer Email | R***********@e*******.com |
| Narrative | On april 30, 2020 at 07:53 cdt, griffith terminal personnel notified the edmonton control center (ecc) of a suspicious odor and the terminal was shutdown. An investigation of the facility was initiated requiring all tanks to be climbed. It was determined that the odor originated from an open vent on tank 76 due to high water on the roof while it was at working bottoms. The remainder of the tanks were climbed in order to give ecc approval to restart the terminal. At approximately 09:00 cdt, a griffith terminal maintainer climbed tank 71 and discovered an active release on the tank roof. Following several heavy rains, the water on the external floating tank roof displaced the roof causing the pin holes on the top of the center tank legs to drop below the product level in the tank spilling oil onto the roof. The tank was isolated and locked out, and the approval to restart the terminal was given to ecc. Pipeline maintenance personnel were onsite and initiated cleanup of the tank roof. A triple filter system was installed on the roof drain to safely drain water from the roof. After cleanup was complete, tank 71 was returned to service. |