Incident details
Operator, cause, commodity and consequences with raw source fields.
GD incident on 2019-07-31 — PA
Operator
Columbia Gas Of Pennsylvania
Cause
Incorrect Operation
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities
1 injury
Property damage (nominal)
$337
Incident datetime
2019-07-31 16:03
Report number
Location
PA, WASHINGTON
Narrative
On july 31, 2019 a home at 100 park lane, washington, pa exploded. Three emergency responders and the customer at 100 park lane were sent to the hospital, one of whom required admittance. There were no life threatening injuries. The company was in the final stages of a pressure uprate project. The gas system pressure was being increased from low pressure (inches of water column) to medium pressure (40 psig). Service and mainline records did not indicate that 100 park lane was served from the system being uprated. Therefore a service regulator was not installed at the meter on the premises to control elevated pressure. Since no service regulator was installed, gas entered the house and reached appliances at a line pressure of 40 psig. The fire marshal's report indicates that the furnace in the home was the source of ignition. After the incident, it was discovered the service line for 100 park lane was tapped into a mainline that was part of the uprate project.
Detailed record list
Occurred At
2019-07-31 16:03:00
Year
2019
Report Received Date
2019-08-30 00:00:00
Iyear
2019.0
Report Number
20190095.0
Supplemental Number
36146.0
Report Type
Supplemental Final
Operator Id
2600
Name
Columbia Gas Of Pennsylvania
Operator Street Address
121 Champion Way Suite 100
Operator City Name
Canonsburg
Operator State Abbreviation
PA
Operator Postal Code
15317
Local Datetime
2019-07-31 15:45:00
Time Zone
Eastern
Daylight Savings Ind
Yes
Location Street Address
100 Park Lane
Location City Name
Washington
Location County Name
Washington
Location State Abbreviation
PA
Location Postal Code
15301
Location Latitude
40.163007
Location Longitude
-80.252453
Flow Cont Key Crit Ind
Yes
Nrc Rpt Datetime
2019-07-31 16:29:00
Nrc Rpt Num
1253797
Commodity Released Type
Natural Gas
Unintentional Release
3.0
Intentional Release
0.0
Fatality Ind
No
Fatal
0
Injury Ind
Yes
Num Emp Injuries
0
Num Contr Injuries
0
Num Er Injuries
1
Num Worker Injuries
0
Num Gp Injuries
0
Injure
1
Ignite Ind
No
Num Pub Evacuated
0.0
Incident Identified Datetime
2019-07-31 16:03:00
On Site Datetime
2019-07-31 16:03:00
Federal
No
Location Type
Private Property
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
24.0
Other Underground Facilities
No
Crossing
No
Pipe Facility Type
Privately Owned
System Part Involved
Service
Installation Year
2013.0
Customer Type
Single Family Residential
Was Efv Installed Before Ind
No
Curb Valve Inst Before Inc Ind
No
Pipe Diameter
1.0
Pipe Specification
Unknown
Pipe Manufacturer
Unknown
Material Involved
Plastic
Plastic Type
Polyethylene (Pe)
Wt Plastic Unknown Ind
Unknown
Material Pe Pipe Code
Unknown
Release Type
Leak
Leak Type
Other
Leak Type Other
No Regulator For Uprate
Class Location Type
Class 3 Location
Est Cost Oper Paid
272000.0
Est Cost Prop Damage
337.0
Est Cost Emergency
10000.0
Est Cost Other
0.0
Gas Cost In Mcf
0.0
Est Cost Unintentional Release
0.0
Est Cost Intentional Release
0.0
Prpty
282337.0
Commercial Affected
0.0
Industrial Affected
0.0
Residences Affected
63.0
Num Persons Hosp Not Ovnght
2.0
Num Injured Treated By Emt
0.0
Num Resident Building Affctd
1.0
Num Business Building Affctd
0.0
Accident Psig
40.0
Normal Psig
40.0
Mop Psig
45.0
Mop Cfr Section
192.619(A)(2)
Maop Established Date
1982-07-15 00:00:00
Accident Pressure
Pressure Did Not Exceed Maop
Gas Odorized System Type
Odorized By Others
Gas Odorized Level
4
Scada In Place Ind
No
Accident Identifier
Notification From Emergency Responder
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind
Yes
Num Employees Tested
9
Num Employees Failed
0
Contractor Drug Test Ind
Yes
Num Contractors Tested
8
Num Contractors Failed
0
Cause
Incorrect Operation
Cause Details
Other Incorrect Operation
Operation Type
Other Incorrect Operation
Operation Details
Service Regulator Was Not Installed At 100 Park Lane, Washington, Pa Before Increasing Line Pressure As Part Of An Uprate Operation.
Related Other Ind
Yes
Operation Related Details
While The Company Has Established Procedures And Processes To Be Taken For Uprates That Include Review Of Materials, Maps, And Records, In This Instance That Review Did Not Identify 100 Park Lane, Washington, Pa As Being Served From The System That Was Involved In The Uprate Project.
Category Type
Construction
Operator Qualification Ind
Yes
Qualified Individuals
Yes, They Were Qualified For The Task(S)
Preparer Name
R****** B****
Preparer Title
Operations Compliance Manager
Preparer Email
R*****@n*******.com
Preparer Telephone
17243217155
Authorizer Name
C***** J* A******
Authorizer Telephone
4199576404
Authorizer Email
C********@n*******.com
Narrative
On july 31, 2019 a home at 100 park lane, washington, pa exploded. Three emergency responders and the customer at 100 park lane were sent to the hospital, one of whom required admittance. There were no life threatening injuries. The company was in the final stages of a pressure uprate project. The gas system pressure was being increased from low pressure (inches of water column) to medium pressure (40 psig). Service and mainline records did not indicate that 100 park lane was served from the system being uprated. Therefore a service regulator was not installed at the meter on the premises to control elevated pressure. Since no service regulator was installed, gas entered the house and reached appliances at a line pressure of 40 psig. The fire marshal's report indicates that the furnace in the home was the source of ignition. After the incident, it was discovered the service line for 100 park lane was tapped into a mainline that was part of the uprate project.
| Occurred At | 2019-07-31 16:03:00 |
|---|---|
| Year | 2019 |
| Report Received Date | 2019-08-30 00:00:00 |
| Iyear | 2019.0 |
| Report Number | 20190095.0 |
| Supplemental Number | 36146.0 |
| Report Type | Supplemental Final |
| Operator Id | 2600 PHMSA Enforcement |
| Name | Columbia Gas Of Pennsylvania |
| Operator Street Address | 121 Champion Way Suite 100 |
| Operator City Name | Canonsburg |
| Operator State Abbreviation | PA |
| Operator Postal Code | 15317 |
| Local Datetime | 2019-07-31 15:45:00 |
| Time Zone | Eastern |
| Daylight Savings Ind | Yes |
| Location Street Address | 100 Park Lane |
| Location City Name | Washington |
| Location County Name | Washington |
| Location State Abbreviation | PA |
| Location Postal Code | 15301 |
| Location Latitude | 40.163007 Google Maps OpenStreetMap |
| Location Longitude | -80.252453 Google Maps OpenStreetMap |
| Flow Cont Key Crit Ind | Yes |
| Nrc Rpt Datetime | 2019-07-31 16:29:00 |
| Nrc Rpt Num | 1253797 NRC Report How to search |
| Commodity Released Type | Natural Gas |
| Unintentional Release | 3.0 |
| Intentional Release | 0.0 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | Yes |
| Num Emp Injuries | 0 |
| Num Contr Injuries | 0 |
| Num Er Injuries | 1 |
| Num Worker Injuries | 0 |
| Num Gp Injuries | 0 |
| Injure | 1 |
| Ignite Ind | No |
| Num Pub Evacuated | 0.0 |
| Incident Identified Datetime | 2019-07-31 16:03:00 |
| On Site Datetime | 2019-07-31 16:03:00 |
| Federal | No |
| Location Type | Private Property |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Soil |
| Depth Of Cover | 24.0 |
| Other Underground Facilities | No |
| Crossing | No |
| Pipe Facility Type | Privately Owned |
| System Part Involved | Service |
| Installation Year | 2013.0 |
| Customer Type | Single Family Residential |
| Was Efv Installed Before Ind | No |
| Curb Valve Inst Before Inc Ind | No |
| Pipe Diameter | 1.0 |
| Pipe Specification | Unknown |
| Pipe Manufacturer | Unknown |
| Material Involved | Plastic |
| Plastic Type | Polyethylene (Pe) |
| Wt Plastic Unknown Ind | Unknown |
| Material Pe Pipe Code | Unknown |
| Release Type | Leak |
| Leak Type | Other |
| Leak Type Other | No Regulator For Uprate |
| Class Location Type | Class 3 Location |
| Est Cost Oper Paid | 272000.0 |
| Est Cost Prop Damage | 337.0 |
| Est Cost Emergency | 10000.0 |
| Est Cost Other | 0.0 |
| Gas Cost In Mcf | 0.0 |
| Est Cost Unintentional Release | 0.0 |
| Est Cost Intentional Release | 0.0 |
| Prpty | 282337.0 |
| Commercial Affected | 0.0 |
| Industrial Affected | 0.0 |
| Residences Affected | 63.0 |
| Num Persons Hosp Not Ovnght | 2.0 |
| Num Injured Treated By Emt | 0.0 |
| Num Resident Building Affctd | 1.0 |
| Num Business Building Affctd | 0.0 |
| Accident Psig | 40.0 |
| Normal Psig | 40.0 |
| Mop Psig | 45.0 |
| Mop Cfr Section | 192.619(A)(2) View CFR 49 §192 |
| Maop Established Date | 1982-07-15 00:00:00 |
| Accident Pressure | Pressure Did Not Exceed Maop |
| Gas Odorized System Type | Odorized By Others |
| Gas Odorized Level | 4 |
| Scada In Place Ind | No |
| Accident Identifier | Notification From Emergency Responder |
| Investigation Status | No, the facility was not monitored by a controller(s) at the time of the incident |
| Employee Drug Test Ind | Yes |
| Num Employees Tested | 9 |
| Num Employees Failed | 0 |
| Contractor Drug Test Ind | Yes |
| Num Contractors Tested | 8 |
| Num Contractors Failed | 0 |
| Cause | Incorrect Operation |
| Cause Details | Other Incorrect Operation |
| Operation Type | Other Incorrect Operation |
| Operation Details | Service Regulator Was Not Installed At 100 Park Lane, Washington, Pa Before Increasing Line Pressure As Part Of An Uprate Operation. |
| Related Other Ind | Yes |
| Operation Related Details | While The Company Has Established Procedures And Processes To Be Taken For Uprates That Include Review Of Materials, Maps, And Records, In This Instance That Review Did Not Identify 100 Park Lane, Washington, Pa As Being Served From The System That Was Involved In The Uprate Project. |
| Category Type | Construction |
| Operator Qualification Ind | Yes |
| Qualified Individuals | Yes, They Were Qualified For The Task(S) |
| Preparer Name | R****** B**** |
| Preparer Title | Operations Compliance Manager |
| Preparer Email | R*****@n*******.com |
| Preparer Telephone | 17243217155 |
| Authorizer Name | C***** J* A****** |
| Authorizer Telephone | 4199576404 |
| Authorizer Email | C********@n*******.com |
| Narrative | On july 31, 2019 a home at 100 park lane, washington, pa exploded. Three emergency responders and the customer at 100 park lane were sent to the hospital, one of whom required admittance. There were no life threatening injuries. The company was in the final stages of a pressure uprate project. The gas system pressure was being increased from low pressure (inches of water column) to medium pressure (40 psig). Service and mainline records did not indicate that 100 park lane was served from the system being uprated. Therefore a service regulator was not installed at the meter on the premises to control elevated pressure. Since no service regulator was installed, gas entered the house and reached appliances at a line pressure of 40 psig. The fire marshal's report indicates that the furnace in the home was the source of ignition. After the incident, it was discovered the service line for 100 park lane was tapped into a mainline that was part of the uprate project. |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company