GD incident on 2019-06-06 — TX

Operator
Centerpoint Energy Resources Corporation
Cause
Incorrect Operation
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities 2 injuries
Property damage (nominal)
$28,000
Incident datetime
2019-06-06 18:42
Report number
Location
TX, GALVESTON
Narrative
While a contractor's crew was performing tapping operations, a crew member inadvertently bumped the slide valve open and natural gas was released. The contractor has identified a grinder at the job site as a probable source of ignition."
Detailed record list
Occurred At
2019-06-06 18:42:00
Year
2019
Report Received Date
2019-07-03 00:00:00
Iyear
2019.0
Report Number
20190067.0
Supplemental Number
32376.0
Report Type
Original Final
Operator Id
Name
Centerpoint Energy Resources Corporation
Operator Street Address
1111 Louisiana St
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2019-06-06 18:42:00
Location Street Address
5415 Avenue M
Location City Name
Santa Fe
Location County Name
Galveston
Location State Abbreviation
TX
Location Postal Code
77510
Location Latitude
Location Longitude
Nrc Rpt Datetime
2019-06-06 19:40:00
Nrc Rpt Num
Commodity Released Type
Natural Gas
Unintentional Release
165.0
Fatality Ind
No
Fatal
0
Injury Ind
Yes
Num Emp Injuries
0
Num Contr Injuries
2
Num Er Injuries
0
Num Worker Injuries
0
Num Gp Injuries
0
Injure
2
Ignite Ind
Yes
Explode Ind
No
Num Pub Evacuated
0.0
Incident Identified Datetime
2019-06-06 18:42:00
On Site Datetime
2019-06-06 18:42:00
Federal
No
Location Type
Utility Right-Of-Way / Easement
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
48.0
Crossing
No
Pipe Facility Type
Privately Owned
System Part Involved
Main
Installation Year
1947.0
Pipe Diameter
2.75
Pipe Specification
Api 5l A-25
Pipe Manufacturer
Unknown
Material Involved
Steel
Steel Seam Type
Other
Steel Seam Type Details
Unknown
Wt Steel
0.21
Release Type
Other
Release Type Details
Tapping Valve Inadvertently Bumped In The Open Position.
Class Location Type
Class 3 Location
Est Cost Oper Paid
8200.0
Est Cost Prop Damage
28000.0
Est Cost Emergency
5090.0
Est Cost Other
0.0
Est Cost Unintentional Release
976.0
Prpty
42266.0
Commercial Affected
0.0
Industrial Affected
0.0
Residences Affected
6.0
Accident Psig
40.0
Normal Psig
40.0
Mop Psig
60.0
Accident Pressure
Pressure Did Not Exceed Maop
Scada In Place Ind
No
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Contractor Working For The Operator
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Incorrect Operation
Cause Details
Valve Left Or Placed In Wrong Position, But Not Resulting In An Overpressure
Operation Type
Valve Left Or Placed In Wrong Position, But Not Resulting In An Overpressure
Related Failure Follow Ind
Yes
Category Type
Construction
Operator Qualification Ind
Yes
Qualified Individuals
Yes, They Were Qualified For The Task(S)
Preparer Name
L***** D********
Preparer Title
Compliance Coordinator Ll
Preparer Email
L***************@c****************.com
Preparer Telephone
713-967-7325
Preparer Fax
713-923-7307
Authorizer Name
S**** Y********
Authorizer Title
Regional Operations Director
Authorizer Telephone
713-207-5700
Authorizer Email
S****************@c****************.com
Narrative
While a contractor's crew was performing tapping operations, a crew member inadvertently bumped the slide valve open and natural gas was released. The contractor has identified a grinder at the job site as a probable source of ignition."
Occurred At 2019-06-06 18:42:00
Year 2019
Report Received Date 2019-07-03 00:00:00
Iyear 2019.0
Report Number 20190067.0
Supplemental Number 32376.0
Report Type Original Final
Operator Id 4499 PHMSA Enforcement
Name Centerpoint Energy Resources Corporation
Operator Street Address 1111 Louisiana St
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77002
Local Datetime 2019-06-06 18:42:00
Location Street Address 5415 Avenue M
Location City Name Santa Fe
Location County Name Galveston
Location State Abbreviation TX
Location Postal Code 77510
Location Latitude 29.36546 Google Maps OpenStreetMap
Location Longitude -95.08938 Google Maps OpenStreetMap
Nrc Rpt Datetime 2019-06-06 19:40:00
Nrc Rpt Num 1248095 NRC Report How to search
Commodity Released Type Natural Gas
Unintentional Release 165.0
Fatality Ind No
Fatal 0
Injury Ind Yes
Num Emp Injuries 0
Num Contr Injuries 2
Num Er Injuries 0
Num Worker Injuries 0
Num Gp Injuries 0
Injure 2
Ignite Ind Yes
Explode Ind No
Num Pub Evacuated 0.0
Incident Identified Datetime 2019-06-06 18:42:00
On Site Datetime 2019-06-06 18:42:00
Federal No
Location Type Utility Right-Of-Way / Easement
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 48.0
Crossing No
Pipe Facility Type Privately Owned
System Part Involved Main
Installation Year 1947.0
Pipe Diameter 2.75
Pipe Specification Api 5l A-25
Pipe Manufacturer Unknown
Material Involved Steel
Steel Seam Type Other
Steel Seam Type Details Unknown
Wt Steel 0.21
Release Type Other
Release Type Details Tapping Valve Inadvertently Bumped In The Open Position.
Class Location Type Class 3 Location
Est Cost Oper Paid 8200.0
Est Cost Prop Damage 28000.0
Est Cost Emergency 5090.0
Est Cost Other 0.0
Est Cost Unintentional Release 976.0
Prpty 42266.0
Commercial Affected 0.0
Industrial Affected 0.0
Residences Affected 6.0
Accident Psig 40.0
Normal Psig 40.0
Mop Psig 60.0
Accident Pressure Pressure Did Not Exceed Maop
Scada In Place Ind No
Accident Identifier Local Operating Personnel, Including Contractors
Operator Type Contractor Working For The Operator
Investigation Status No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Incorrect Operation
Cause Details Valve Left Or Placed In Wrong Position, But Not Resulting In An Overpressure
Operation Type Valve Left Or Placed In Wrong Position, But Not Resulting In An Overpressure
Related Failure Follow Ind Yes
Category Type Construction
Operator Qualification Ind Yes
Qualified Individuals Yes, They Were Qualified For The Task(S)
Preparer Name L***** D********
Preparer Title Compliance Coordinator Ll
Preparer Email L***************@c****************.com
Preparer Telephone 713-967-7325
Preparer Fax 713-923-7307
Authorizer Name S**** Y********
Authorizer Title Regional Operations Director
Authorizer Telephone 713-207-5700
Authorizer Email S****************@c****************.com
Narrative While a contractor's crew was performing tapping operations, a crew member inadvertently bumped the slide valve open and natural gas was released. The contractor has identified a grinder at the job site as a probable source of ignition."

All rights reserved. Copyright © by ClearPHMSA