GD incident on 2019-05-15 — MI

Operator
Michigan Gas Utilities Co
Cause
Excavation Issue
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$71,002
Incident datetime
2019-05-15 13:55
Report number
Location
MI, OTTAWA
Narrative
3/4' steel service tee attached our 4' high pressure steel gas main at 408 w exchange was broke off of the gas main by the blade of a bulldozer while the area was being backfilled by the west michigan dirtworks road construction crew at approx. 1:45pm on 5/15/19. Damaging party called an mgu employee directly at 1:43pm to notify of damage. Damaging party then called the mgu gas emergency # at 1:55pm. Ten nearby houses downwind of the damage were evacuated by emergency responders and mgu employees as a safety precaution. It was decided the blowing gas was escaping into the atmosphere was not presenting an immediate danger and mgu and kpi would proceed with installing a permanent bypass around the damage location. During the course of this repair, mgu employees were routinely checking gas concentration levels in the air and buildings downwind of the blowing gas. At approx. 9:15am on friday 5/17/19, the stoppers were set and the blowing gas was stopped. A service tech arrived on site at approx. 1pm and began turning on gas to the customers that were turned off as a safety precaution. The entire project was completed at approx. 6pm on friday 5/17/19. Original nrc report number is 1245847, revised nrc report number is 1246181.
Detailed record list
Occurred At
2019-05-15 13:55:00
Year
2019
Report Received Date
2019-06-14 00:00:00
Iyear
2019.0
Report Number
20190059.0
Supplemental Number
32466.0
Report Type
Supplemental Final
Operator Id
Name
Michigan Gas Utilities Co
Operator Street Address
899 S Telegraph Road
Operator City Name
Monroe
Operator State Abbreviation
MI
Operator Postal Code
48161
Local Datetime
2019-05-15 13:40:00
Location Street Address
408 W. Exchange St
Location City Name
Spring Lake
Location County Name
Ottawa
Location State Abbreviation
MI
Location Postal Code
49456
Location Latitude
Location Longitude
Nrc Rpt Datetime
2019-05-16 11:09:00
Nrc Rpt Num
Commodity Released Type
Natural Gas
Unintentional Release
1773.0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Ignite Ind
No
Explode Ind
No
Num Pub Evacuated
4.0
Incident Identified Datetime
2019-05-15 13:55:00
On Site Datetime
2019-05-15 13:58:00
Federal
No
Location Type
Public Property
Incident Area Type
Underground
Incident Area Subtype
Exposed Due To Excavation
Depth Of Cover
28.0
Crossing
No
Pipe Facility Type
Investor Owned
System Part Involved
Main
Installation Year
1959.0
Pipe Diameter
4.5
Pipe Specification
Unknown
Pipe Manufacturer
Unknown
Material Involved
Steel
Steel Seam Type
Other
Steel Seam Type Details
Unknown
Wt Steel
0.237
Release Type
Other
Release Type Details
Bulldozer Knocked A Tee Off The Main. The Hole Was 3/8" Diameter
Class Location Type
Class 3 Location
Est Cost Oper Paid
0.0
Est Cost Prop Damage
71002.0
Est Cost Emergency
8178.0
Est Cost Other
0.0
Est Cost Unintentional Release
6102.0
Prpty
85282.0
Commercial Affected
1.0
Industrial Affected
0.0
Residences Affected
9.0
Accident Psig
352.0
Normal Psig
350.0
Mop Psig
400.0
Accident Pressure
Pressure Did Not Exceed Maop
Scada In Place Ind
No
Accident Identifier
Notification From Third Party That Caused The Incident
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Excavation Damage
Cause Details
Excavation Damage By Third Party
Ex Party Type
Excavation Damage By Third Party
Prior Notification Ind
Yes
One Call System Ind
Yes
Notify Cga Dirt
No
Public Row Ind
Yes
Public Subtype
City Street
Excavator Type
Contractor
Excavator Equipment
Grader/scraper
Work Performed
Sewer (Sanitary/storm)
One Call Notified Ind
Yes
One Call Ticket Num
90160331
Locator Type
Utility Owner
Visible Marks
Yes
Root Cause Category
Excavation Issue
Root Cause Type
Improper Excavation Practice Not Listed Above
Preparer Name
N***** L**
Preparer Title
Compliance Supervisor
Preparer Email
N*********@m*******************.com
Preparer Telephone
517-278-3524
Preparer Fax
517-278-3528
Authorizer Name
N***** L**
Authorizer Title
Compliance Supervisor
Authorizer Telephone
517-278-3524
Authorizer Email
N*********@m*******************.com
Narrative
3/4' steel service tee attached our 4' high pressure steel gas main at 408 w exchange was broke off of the gas main by the blade of a bulldozer while the area was being backfilled by the west michigan dirtworks road construction crew at approx. 1:45pm on 5/15/19. Damaging party called an mgu employee directly at 1:43pm to notify of damage. Damaging party then called the mgu gas emergency # at 1:55pm. Ten nearby houses downwind of the damage were evacuated by emergency responders and mgu employees as a safety precaution. It was decided the blowing gas was escaping into the atmosphere was not presenting an immediate danger and mgu and kpi would proceed with installing a permanent bypass around the damage location. During the course of this repair, mgu employees were routinely checking gas concentration levels in the air and buildings downwind of the blowing gas. At approx. 9:15am on friday 5/17/19, the stoppers were set and the blowing gas was stopped. A service tech arrived on site at approx. 1pm and began turning on gas to the customers that were turned off as a safety precaution. The entire project was completed at approx. 6pm on friday 5/17/19. Original nrc report number is 1245847, revised nrc report number is 1246181.
Occurred At 2019-05-15 13:55:00
Year 2019
Report Received Date 2019-06-14 00:00:00
Iyear 2019.0
Report Number 20190059.0
Supplemental Number 32466.0
Report Type Supplemental Final
Operator Id 12420 PHMSA Enforcement
Name Michigan Gas Utilities Co
Operator Street Address 899 S Telegraph Road
Operator City Name Monroe
Operator State Abbreviation MI
Operator Postal Code 48161
Local Datetime 2019-05-15 13:40:00
Location Street Address 408 W. Exchange St
Location City Name Spring Lake
Location County Name Ottawa
Location State Abbreviation MI
Location Postal Code 49456
Location Latitude 43.075637 Google Maps OpenStreetMap
Location Longitude -86.202413 Google Maps OpenStreetMap
Nrc Rpt Datetime 2019-05-16 11:09:00
Nrc Rpt Num 1245847 NRC Report How to search
Commodity Released Type Natural Gas
Unintentional Release 1773.0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Ignite Ind No
Explode Ind No
Num Pub Evacuated 4.0
Incident Identified Datetime 2019-05-15 13:55:00
On Site Datetime 2019-05-15 13:58:00
Federal No
Location Type Public Property
Incident Area Type Underground
Incident Area Subtype Exposed Due To Excavation
Depth Of Cover 28.0
Crossing No
Pipe Facility Type Investor Owned
System Part Involved Main
Installation Year 1959.0
Pipe Diameter 4.5
Pipe Specification Unknown
Pipe Manufacturer Unknown
Material Involved Steel
Steel Seam Type Other
Steel Seam Type Details Unknown
Wt Steel 0.237
Release Type Other
Release Type Details Bulldozer Knocked A Tee Off The Main. The Hole Was 3/8" Diameter
Class Location Type Class 3 Location
Est Cost Oper Paid 0.0
Est Cost Prop Damage 71002.0
Est Cost Emergency 8178.0
Est Cost Other 0.0
Est Cost Unintentional Release 6102.0
Prpty 85282.0
Commercial Affected 1.0
Industrial Affected 0.0
Residences Affected 9.0
Accident Psig 352.0
Normal Psig 350.0
Mop Psig 400.0
Accident Pressure Pressure Did Not Exceed Maop
Scada In Place Ind No
Accident Identifier Notification From Third Party That Caused The Incident
Investigation Status No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Excavation Damage
Cause Details Excavation Damage By Third Party
Ex Party Type Excavation Damage By Third Party
Prior Notification Ind Yes
One Call System Ind Yes
Notify Cga Dirt No
Public Row Ind Yes
Public Subtype City Street
Excavator Type Contractor
Excavator Equipment Grader/scraper
Work Performed Sewer (Sanitary/storm)
One Call Notified Ind Yes
One Call Ticket Num 90160331
Locator Type Utility Owner
Visible Marks Yes
Root Cause Category Excavation Issue
Root Cause Type Improper Excavation Practice Not Listed Above
Preparer Name N***** L**
Preparer Title Compliance Supervisor
Preparer Email N*********@m*******************.com
Preparer Telephone 517-278-3524
Preparer Fax 517-278-3528
Authorizer Name N***** L**
Authorizer Title Compliance Supervisor
Authorizer Telephone 517-278-3524
Authorizer Email N*********@m*******************.com
Narrative 3/4' steel service tee attached our 4' high pressure steel gas main at 408 w exchange was broke off of the gas main by the blade of a bulldozer while the area was being backfilled by the west michigan dirtworks road construction crew at approx. 1:45pm on 5/15/19. Damaging party called an mgu employee directly at 1:43pm to notify of damage. Damaging party then called the mgu gas emergency # at 1:55pm. Ten nearby houses downwind of the damage were evacuated by emergency responders and mgu employees as a safety precaution. It was decided the blowing gas was escaping into the atmosphere was not presenting an immediate danger and mgu and kpi would proceed with installing a permanent bypass around the damage location. During the course of this repair, mgu employees were routinely checking gas concentration levels in the air and buildings downwind of the blowing gas. At approx. 9:15am on friday 5/17/19, the stoppers were set and the blowing gas was stopped. A service tech arrived on site at approx. 1pm and began turning on gas to the customers that were turned off as a safety precaution. The entire project was completed at approx. 6pm on friday 5/17/19. Original nrc report number is 1245847, revised nrc report number is 1246181.