HL incident on 2018-10-22 — TX

Operator
Boardwalk Louisiana Midstream, Llc
Cause
Incorrect Operation
Commodity
Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$20,000
Incident datetime
2018-10-22 16:20
Report number
Location
TX
Narrative
During pump commissioning on the brimstone project, the pump's rotation and the clips on the seals were set up incorrectly by the manufacturer. This caused the seals to fail and a small fire ignited but was extinguished by employees with hand held first extinguisher; the fire lasted 5-7 seconds. One gallon of barrier fluid was released; further investigation revealed a small trace of ethylene was released with the barrier fluid so the incident was then reported to the nrc. The cost shown in part d reflects the only cost incurred by bwp which was to refill and certify the used fire extinguisher. Any other cost was absorbed by the manufacturer as this accident was the result of manufacturer installation error. 12-5-18 revised to include cost incurred by manufacturer ($20,000), per PHMSA instructions via email.
Detailed record list
Report Received Date
2018-11-08 00:00:00
Iyear
2018
Report Number
20180342
Supplemental Number
31276
Report Type
Supplemental Final
Operator Id
Name
Boardwalk Louisiana Midstream, Llc
Operator Street Address
9 Greenway Plaza
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77046
Local Datetime
2018-10-24 08:30:00
Location Latitude
Location Longitude
Commodity Released Type
Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Commodity Subtype
Other Hvl
Commodity Details
Ethylene
Unintentional Release Bbls
0.1
Intentional Release Bbls
0
Recovered Bbls
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
Incident Identified Datetime
2018-10-22 16:20:00
System Part Involved
Onshore Terminal/tank Farm Equipment And Piping
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2018-10-22 16:20:00
Restart Datetime
2018-10-28 11:00:00
On Site Datetime
2018-10-22 16:20:00
Nrc Rpt Datetime
2018-10-24 08:30:00
Nrc Rpt Num
Ignite Ind
Yes
Explode Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Brimstone Terminal - Regen System
Onshore State Abbreviation
La
Onshore Postal Code
70663
Onshore City Name
Sulphur
Onshore County Name
Calcasieu
Designated Location
Milepost/valve Station
Designated Name
0
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Other
Incident Area Details
Terminal
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Pump
Installation Year
2018
Material Involved
Carbon Steel
Release Type
Other
Release Type Details
Pump Seal Failed And Ignited
Wildlife Impact Ind
No
Soil Contamination
No
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
0
Est Cost Prop Damage
20000
Est Cost Emergency
300
Est Cost Environmental
0
Est Cost Other
0
Prpty
20300
Accident Psig
1315
Mop Psig
1440
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
Yes
Scada Conf Ind
Yes
Cpm In Place Ind
No
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the accident
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Incorrect Operation
Cause Details
Other Incorrect Operation
Operation Type
Other Incorrect Operation
Operation Details
The Pump's Rotation And The Clips On The Seals Were Set Up Incorrectly By The Manufacturer Which Caused The Seals To Fail And A Small Fire Ignited.
Related Other Ind
Yes
Operation Related Details
The Pump's Rotation And The Clips On The Seals Were Set Up Incorrectly By The Manufacturer Which Caused The Seals To Fail And A Small Fire Ignited.
Category Type
Commissioning
Operator Qualification Ind
No
Preparer Name
S****** M********
Preparer Title
Pa Oq And Event Program Leader
Preparer Email
S****************@b*****.com
Preparer Telephone
2706886357
Prepared Date
2018-12-05 00:00:00
Authorizer Name
D***** W***
Authorizer Telephone
2706886356
Authorizer Title
Manager Pipeline Safety
Authorizer Email
D**********@b*****.com
Narrative
During pump commissioning on the brimstone project, the pump's rotation and the clips on the seals were set up incorrectly by the manufacturer. This caused the seals to fail and a small fire ignited but was extinguished by employees with hand held first extinguisher; the fire lasted 5-7 seconds. One gallon of barrier fluid was released; further investigation revealed a small trace of ethylene was released with the barrier fluid so the incident was then reported to the nrc. The cost shown in part d reflects the only cost incurred by bwp which was to refill and certify the used fire extinguisher. Any other cost was absorbed by the manufacturer as this accident was the result of manufacturer installation error. 12-5-18 revised to include cost incurred by manufacturer ($20,000), per PHMSA instructions via email.
Report Received Date 2018-11-08 00:00:00
Iyear 2018
Report Number 20180342
Supplemental Number 31276
Report Type Supplemental Final
Operator Id 39138 PHMSA Enforcement
Name Boardwalk Louisiana Midstream, Llc
Operator Street Address 9 Greenway Plaza
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77046
Local Datetime 2018-10-24 08:30:00
Location Latitude 30.25032818 Google Maps OpenStreetMap
Location Longitude -93.4056924 Google Maps OpenStreetMap
Commodity Released Type Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Commodity Subtype Other Hvl
Commodity Details Ethylene
Unintentional Release Bbls 0.1
Intentional Release Bbls 0
Recovered Bbls 0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Local Operating Personnel, Including Contractors
Operator Type Operator Employee
Incident Identified Datetime 2018-10-22 16:20:00
System Part Involved Onshore Terminal/tank Farm Equipment And Piping
On Off Shore Onshore
Shutdown Due Accident Ind Yes
Shutdown Datetime 2018-10-22 16:20:00
Restart Datetime 2018-10-28 11:00:00
On Site Datetime 2018-10-22 16:20:00
Nrc Rpt Datetime 2018-10-24 08:30:00
Nrc Rpt Num 1228366 NRC Report How to search
Ignite Ind Yes
Explode Ind No
Num Pub Evacuated 0
Pipe Fac Name Brimstone Terminal - Regen System
Onshore State Abbreviation La
Onshore Postal Code 70663
Onshore City Name Sulphur
Onshore County Name Calcasieu
Designated Location Milepost/valve Station
Designated Name 0
Federal No
Location Type Totally Contained On Operator-Controlled Property
Incident Area Type Aboveground
Incident Area Subtype Other
Incident Area Details Terminal
Crossing No
Pipe Facility Type Intrastate
Item Involved Pump
Installation Year 2018
Material Involved Carbon Steel
Release Type Other
Release Type Details Pump Seal Failed And Ignited
Wildlife Impact Ind No
Soil Contamination No
Long Term Assessment No
Remediation Ind No
Water Contam Ind No
Could Be Hca No
Commodity Reached Hca No
Est Cost Oper Paid 0
Est Cost Gas Released 0
Est Cost Prop Damage 20000
Est Cost Emergency 300
Est Cost Environmental 0
Est Cost Other 0
Prpty 20300
Accident Psig 1315
Mop Psig 1440
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind Yes
Scada Conf Ind Yes
Cpm In Place Ind No
Investigation Status No, the facility was not monitored by a controller(s) at the time of the accident
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Incorrect Operation
Cause Details Other Incorrect Operation
Operation Type Other Incorrect Operation
Operation Details The Pump's Rotation And The Clips On The Seals Were Set Up Incorrectly By The Manufacturer Which Caused The Seals To Fail And A Small Fire Ignited.
Related Other Ind Yes
Operation Related Details The Pump's Rotation And The Clips On The Seals Were Set Up Incorrectly By The Manufacturer Which Caused The Seals To Fail And A Small Fire Ignited.
Category Type Commissioning
Operator Qualification Ind No
Preparer Name S****** M********
Preparer Title Pa Oq And Event Program Leader
Preparer Email S****************@b*****.com
Preparer Telephone 2706886357
Prepared Date 2018-12-05 00:00:00
Authorizer Name D***** W***
Authorizer Telephone 2706886356
Authorizer Title Manager Pipeline Safety
Authorizer Email D**********@b*****.com
Narrative During pump commissioning on the brimstone project, the pump's rotation and the clips on the seals were set up incorrectly by the manufacturer. This caused the seals to fail and a small fire ignited but was extinguished by employees with hand held first extinguisher; the fire lasted 5-7 seconds. One gallon of barrier fluid was released; further investigation revealed a small trace of ethylene was released with the barrier fluid so the incident was then reported to the nrc. The cost shown in part d reflects the only cost incurred by bwp which was to refill and certify the used fire extinguisher. Any other cost was absorbed by the manufacturer as this accident was the result of manufacturer installation error. 12-5-18 revised to include cost incurred by manufacturer ($20,000), per PHMSA instructions via email.

All rights reserved. Copyright © by ClearPHMSA