Operator
Sfpp, Lp
Cause
Material Failure Of Pipe Or Weld
Commodity
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$243,396
Incident datetime
2018-08-05 19:20
Report number
Location
TX
Narrative
On the evening of august 5, 2018, an unknown member of the public made a 911 call of diesel seeping through street cracks on the corner of hillcrest and sunset avenues. Contra costa county fire department arrived on site and notified the local control center at 19:20 using contact information they saw on the adjacent line marker. The line was immediately shut down and local operations arrived on site at 19:58 and mainline isolation valves were closed shortly thereafter. The road was excavated and a 9' section of the line containing a welded reinforcement sleeve on it was cut and removed. The total volume released from this accident is unknown at the time of this report submission, however, 72 bbls has been recovered to date. Supplemental/final update 2/27/19: metallurgical testing revealed that cracks had formed in the upper fillet weld of the 3 o'clock lap bar of the b sleeve that was installed in 1999. When the cracks that had formed in the carrier pipe (as a result of the initial 3rd party damage) grew to the point of failure, the b sleeve subsequently experienced an instantaneous failure due to the reduction in tensile strength because of these cracks in the upper fillet weld when it became exposed for the first time to the pressure of the diesel.
Detailed record list
Report Received Date
2018-09-04 00:00:00
Iyear
2018
Report Number
20180263
Supplemental Number
31713
Report Type
Supplemental Final
Operator Id
18092
Name
Sfpp, Lp
Operator Street Address
1001 Louisiana St., Suite 1000
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2018-08-05 19:20:00
Location Latitude
37.99824
Location Longitude
-121.7863
Commodity Released Type
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype
Diesel, Fuel Oil, Kerosene, Jet Fuel
Unintentional Release Bbls
72
Recovered Bbls
72
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Notification From Emergency Responder
Incident Identified Datetime
2018-08-05 19:20:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2018-08-05 19:20:00
Restart Datetime
2018-08-08 19:48:00
On Site Datetime
2018-08-05 19:58:00
Nrc Rpt Datetime
2018-08-05 20:54:00
Nrc Rpt Num
1220624
Ignite Ind
No
Explode Ind
No
Upstream Valve Type Ind
Automatic
Downstream Valve Type Ind
Manual
Num Pub Evacuated
0
Pipe Fac Name
Ls-90
Segment Name
Ls-90
Onshore State Abbreviation
Ca
Onshore Postal Code
94509
Onshore City Name
Antioch
Onshore County Name
Contra Costa
Designated Location
Milepost/valve Station
Designated Name
17.6
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Pavement
Depth Of Cover
72
Crossing
Yes
Road Crossing Ind
Yes
Road Type
Uncased
Pipe Facility Type
Intrastate
Item Involved
Weld, Including Heat-Affected Zone
Weld Subtype
Fillet Weld
Installation Year
1999
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Crack
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
Yes
Remediation Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
Yes
High Pop Ind
Yes
High Pop Yes No
Yes
Est Cost Oper Paid
0
Est Cost Gas Released
6552
Est Cost Prop Damage
243396
Est Cost Emergency
482458
Est Cost Environmental
5625
Est Cost Other
0
Prpty
738031
Accident Psig
1335
Mop Psig
1440
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
94512
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
Yes, specify investigation result(s): (select all that apply)
Invest Schedule Ind
Yes
Invest No Control Room Ind
Yes
Invest No Controller Ind
Yes
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Material Failure Of Pipe Or Weld
Cause Details
Design-, Construction-, Installation-, Or Fabrication-Related
Field Exam Ind
Yes
Metallurgical Ind
Yes
Failure Type
Design-, Construction-, Installation-, Or Fabrication-Related
Other Factor
Yes
Other Factor Details
Sub-Standard Fillet Weld Made To The Lap Bar Of The B Sleeve
Additional Crack Ind
Yes
Collected Data Ind
Yes
Axial Magnetic Flx Lkg Ind
Yes
Geometry Deformation Ind
Yes
Axial Recent Year
2013
Geometry Recent Year
2013
Has Hydrtst Conduc Before Ind
No
Direct Asmnt Conducted
Yes, And An Investigative Dig Was Cunducted At The Point Of The Accident
Direct Asmnt At Pnt Accdnt Yr
1999
Non Destructive Exam Ind
No
Preparer Name
W*** S******
Preparer Title
Compliance Codes And Standards Specialist
Preparer Email
W***********@k***********.com
Preparer Telephone
6613046971
Prepared Date
2019-02-27 00:00:00
Authorizer Name
Q****** F******
Authorizer Telephone
7707514240
Authorizer Title
Director Compliance Codes And Standards
Authorizer Email
Q**************@k***********.com
Narrative
On the evening of august 5, 2018, an unknown member of the public made a 911 call of diesel seeping through street cracks on the corner of hillcrest and sunset avenues. Contra costa county fire department arrived on site and notified the local control center at 19:20 using contact information they saw on the adjacent line marker. The line was immediately shut down and local operations arrived on site at 19:58 and mainline isolation valves were closed shortly thereafter. The road was excavated and a 9' section of the line containing a welded reinforcement sleeve on it was cut and removed. The total volume released from this accident is unknown at the time of this report submission, however, 72 bbls has been recovered to date. Supplemental/final update 2/27/19: metallurgical testing revealed that cracks had formed in the upper fillet weld of the 3 o'clock lap bar of the b sleeve that was installed in 1999. When the cracks that had formed in the carrier pipe (as a result of the initial 3rd party damage) grew to the point of failure, the b sleeve subsequently experienced an instantaneous failure due to the reduction in tensile strength because of these cracks in the upper fillet weld when it became exposed for the first time to the pressure of the diesel.
| Report Received Date | 2018-09-04 00:00:00 |
|---|---|
| Iyear | 2018 |
| Report Number | 20180263 |
| Supplemental Number | 31713 |
| Report Type | Supplemental Final |
| Operator Id | 18092 PHMSA Enforcement |
| Name | Sfpp, Lp |
| Operator Street Address | 1001 Louisiana St., Suite 1000 |
| Operator City Name | Houston |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77002 |
| Local Datetime | 2018-08-05 19:20:00 |
| Location Latitude | 37.99824 Google Maps OpenStreetMap |
| Location Longitude | -121.7863 Google Maps OpenStreetMap |
| Commodity Released Type | Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions |
| Commodity Subtype | Diesel, Fuel Oil, Kerosene, Jet Fuel |
| Unintentional Release Bbls | 72 |
| Recovered Bbls | 72 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Notification From Emergency Responder |
| Incident Identified Datetime | 2018-08-05 19:20:00 |
| System Part Involved | Onshore Pipeline, Including Valve Sites |
| On Off Shore | Onshore |
| Shutdown Due Accident Ind | Yes |
| Shutdown Datetime | 2018-08-05 19:20:00 |
| Restart Datetime | 2018-08-08 19:48:00 |
| On Site Datetime | 2018-08-05 19:58:00 |
| Nrc Rpt Datetime | 2018-08-05 20:54:00 |
| Nrc Rpt Num | 1220624 NRC Report How to search |
| Ignite Ind | No |
| Explode Ind | No |
| Upstream Valve Type Ind | Automatic |
| Downstream Valve Type Ind | Manual |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Ls-90 |
| Segment Name | Ls-90 |
| Onshore State Abbreviation | Ca |
| Onshore Postal Code | 94509 |
| Onshore City Name | Antioch |
| Onshore County Name | Contra Costa |
| Designated Location | Milepost/valve Station |
| Designated Name | 17.6 |
| Federal | No |
| Location Type | Pipeline Right-Of-Way |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Pavement |
| Depth Of Cover | 72 |
| Crossing | Yes |
| Road Crossing Ind | Yes |
| Road Type | Uncased |
| Pipe Facility Type | Intrastate |
| Item Involved | Weld, Including Heat-Affected Zone |
| Weld Subtype | Fillet Weld |
| Installation Year | 1999 |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Crack |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | Yes |
| Remediation Ind | Yes |
| Soil Remed Ind | Yes |
| Water Contam Ind | No |
| Could Be Hca | Yes |
| Commodity Reached Hca | Yes |
| High Pop Ind | Yes |
| High Pop Yes No | Yes |
| Est Cost Oper Paid | 0 |
| Est Cost Gas Released | 6552 |
| Est Cost Prop Damage | 243396 |
| Est Cost Emergency | 482458 |
| Est Cost Environmental | 5625 |
| Est Cost Other | 0 |
| Prpty | 738031 |
| Accident Psig | 1335 |
| Mop Psig | 1440 |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Length Segment Isolated | 94512 |
| Internal Inspection Ind | Yes |
| Operation Complications Ind | No |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | No |
| Cpm In Place Ind | No |
| Investigation Status | Yes, specify investigation result(s): (select all that apply) |
| Invest Schedule Ind | Yes |
| Invest No Control Room Ind | Yes |
| Invest No Controller Ind | Yes |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Material Failure Of Pipe Or Weld |
| Cause Details | Design-, Construction-, Installation-, Or Fabrication-Related |
| Field Exam Ind | Yes |
| Metallurgical Ind | Yes |
| Failure Type | Design-, Construction-, Installation-, Or Fabrication-Related |
| Other Factor | Yes |
| Other Factor Details | Sub-Standard Fillet Weld Made To The Lap Bar Of The B Sleeve |
| Additional Crack Ind | Yes |
| Collected Data Ind | Yes |
| Axial Magnetic Flx Lkg Ind | Yes |
| Geometry Deformation Ind | Yes |
| Axial Recent Year | 2013 |
| Geometry Recent Year | 2013 |
| Has Hydrtst Conduc Before Ind | No |
| Direct Asmnt Conducted | Yes, And An Investigative Dig Was Cunducted At The Point Of The Accident |
| Direct Asmnt At Pnt Accdnt Yr | 1999 |
| Non Destructive Exam Ind | No |
| Preparer Name | W*** S****** |
| Preparer Title | Compliance Codes And Standards Specialist |
| Preparer Email | W***********@k***********.com |
| Preparer Telephone | 6613046971 |
| Prepared Date | 2019-02-27 00:00:00 |
| Authorizer Name | Q****** F****** |
| Authorizer Telephone | 7707514240 |
| Authorizer Title | Director Compliance Codes And Standards |
| Authorizer Email | Q**************@k***********.com |
| Narrative | On the evening of august 5, 2018, an unknown member of the public made a 911 call of diesel seeping through street cracks on the corner of hillcrest and sunset avenues. Contra costa county fire department arrived on site and notified the local control center at 19:20 using contact information they saw on the adjacent line marker. The line was immediately shut down and local operations arrived on site at 19:58 and mainline isolation valves were closed shortly thereafter. The road was excavated and a 9' section of the line containing a welded reinforcement sleeve on it was cut and removed. The total volume released from this accident is unknown at the time of this report submission, however, 72 bbls has been recovered to date. Supplemental/final update 2/27/19: metallurgical testing revealed that cracks had formed in the upper fillet weld of the 3 o'clock lap bar of the b sleeve that was installed in 1999. When the cracks that had formed in the carrier pipe (as a result of the initial 3rd party damage) grew to the point of failure, the b sleeve subsequently experienced an instantaneous failure due to the reduction in tensile strength because of these cracks in the upper fillet weld when it became exposed for the first time to the pressure of the diesel. |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company
All rights reserved. Copyright © by ClearPHMSA