HL incident on 2018-07-18 — OK

Operator
Magellan Pipeline Company, Lp
Cause
Material Failure Of Pipe Or Weld
Commodity
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$30,000
Incident datetime
2018-07-18 09:15
Report number
Location
OK
Narrative
On 7/18/18, a magellan operator was ground patrolling assets when an area of dead vegetation was observed on the row. At the time of the incident, the frost-hearne line was not running. Operations control was notified and isolation valves on the frost-hearne line were closed. All other magellan pipelines in the area were immediately shut down. Investigative event procedures were implemented and resources responded to the site. Impacted soil was excavated and properly disposed. Field nde indicated the release originated from a crack indication in the erw longitudinal seam. The release was repaired by installation of a type b sleeve. A review of the ultrasonic crack detection inline inspection data was conducted by the ili vendor to identify locations with similar raw data characteristics. Two locations were identified, excavated, and repaired by installation of type b sleeves. 48-hr nrc update: report # 1219024, 7/20/18 15:36 supplemental/final filed updates (09/05/2018 ): part a4, a18 c3a, and part h narrative
Detailed record list
Report Received Date
2018-08-16 00:00:00
Iyear
2018
Report Number
20180242
Supplemental Number
30902
Report Type
Supplemental Final
Operator Id
Name
Magellan Pipeline Company, Lp
Operator Street Address
100 West 5th Street
Operator City Name
Tulsa
Operator State Abbreviation
OK
Operator Postal Code
74103
Local Datetime
2018-07-18 09:15:00
Location Latitude
Location Longitude
Commodity Released Type
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype
Diesel, Fuel Oil, Kerosene, Jet Fuel
Unintentional Release Bbls
35
Recovered Bbls
35
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Ground Patrol By Operator Or Its Contractor
Operator Type
Operator Employee
Incident Identified Datetime
2018-07-18 09:15:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2018-07-18 11:34:00
Restart Datetime
2018-07-19 14:08:00
On Site Datetime
2018-07-18 09:15:00
Nrc Rpt Datetime
2018-07-18 16:59:00
Nrc Rpt Num
Ignite Ind
No
Explode Ind
No
Upstream Valve Type Ind
Remotely Controlled
Downstream Valve Type Ind
Remotely Controlled
Num Pub Evacuated
0
Pipe Fac Name
Hearne - Frost 10"
Segment Name
Line Id 6944
Onshore State Abbreviation
Tx
Onshore Postal Code
76666
Onshore City Name
Mertens
Onshore County Name
Hill
Designated Location
Milepost/valve Station
Designated Name
7.4
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
54
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pipe
Pipe Type
Pipe Seam
Pipe Diameter
10
Pipe Wall Thickness
0.203
Pipe Smys
60000
Pipe Specification
Api5lx-60
Pipe Seam Type
Erw - High Frequency
Pipe Manufacturer
Maverick Steel
Pipe Coating Type
Fusion Bonded Epoxy(Fbe)
Installation Year
2005
Manufactured Year
2005
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Crack
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
Yes
Other Pop Ind
Yes
Other Pop Yes No
Yes
Est Cost Oper Paid
5000
Est Cost Gas Released
4748
Est Cost Prop Damage
30000
Est Cost Emergency
390000
Est Cost Environmental
0
Est Cost Other
0
Prpty
429748
Accident Psig
115
Mop Psig
1440
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
49954
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
The release volume was below detectable thresholds.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Material Failure Of Pipe Or Weld
Cause Details
Original Manufacturing-Related (Not Girth Weld Or Other Welds Formed In The Field)
Field Exam Ind
Yes
Failure Type
Original Manufacturing-Related (Not Girth Weld Or Other Welds Formed In The Field)
Other Factor
Yes
Other Factor Details
No Known Contributing Factors
Additional Crack Ind
Yes
Collected Data Ind
Yes
Emat Ind
Yes
Other Tool Tech Ind
Yes
Emat Recent Year
2018
Other Tool
Tdw Multi-Data Set
Other Recent Year
2018
Has Hydrtst Conduc Before Ind
Yes
Hydrtst Most Rcnt Year
2005
Hydrtst Most Rcnt Pressure
2080
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
S****** L******
Preparer Title
Ai Analyst
Preparer Email
S**************@m*********.com
Preparer Telephone
918-574-7327
Preparer Fax
918-574-7376
Prepared Date
2018-09-05 00:00:00
Authorizer Name
M*** M******
Authorizer Telephone
918-574-7073
Authorizer Title
Mgr Integrity Mgmt And Regulatory Compliance
Authorizer Email
M***********@m*********.com
Narrative
On 7/18/18, a magellan operator was ground patrolling assets when an area of dead vegetation was observed on the row. At the time of the incident, the frost-hearne line was not running. Operations control was notified and isolation valves on the frost-hearne line were closed. All other magellan pipelines in the area were immediately shut down. Investigative event procedures were implemented and resources responded to the site. Impacted soil was excavated and properly disposed. Field nde indicated the release originated from a crack indication in the erw longitudinal seam. The release was repaired by installation of a type b sleeve. A review of the ultrasonic crack detection inline inspection data was conducted by the ili vendor to identify locations with similar raw data characteristics. Two locations were identified, excavated, and repaired by installation of type b sleeves. 48-hr nrc update: report # 1219024, 7/20/18 15:36 supplemental/final filed updates (09/05/2018 ): part a4, a18 c3a, and part h narrative
Report Received Date 2018-08-16 00:00:00
Iyear 2018
Report Number 20180242
Supplemental Number 30902
Report Type Supplemental Final
Operator Id 22610 PHMSA Enforcement
Name Magellan Pipeline Company, Lp
Operator Street Address 100 West 5th Street
Operator City Name Tulsa
Operator State Abbreviation OK
Operator Postal Code 74103
Local Datetime 2018-07-18 09:15:00
Location Latitude 32.054188 Google Maps OpenStreetMap
Location Longitude -96.89515 Google Maps OpenStreetMap
Commodity Released Type Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype Diesel, Fuel Oil, Kerosene, Jet Fuel
Unintentional Release Bbls 35
Recovered Bbls 35
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Ground Patrol By Operator Or Its Contractor
Operator Type Operator Employee
Incident Identified Datetime 2018-07-18 09:15:00
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Shutdown Due Accident Ind Yes
Shutdown Datetime 2018-07-18 11:34:00
Restart Datetime 2018-07-19 14:08:00
On Site Datetime 2018-07-18 09:15:00
Nrc Rpt Datetime 2018-07-18 16:59:00
Nrc Rpt Num 1218780 NRC Report How to search
Ignite Ind No
Explode Ind No
Upstream Valve Type Ind Remotely Controlled
Downstream Valve Type Ind Remotely Controlled
Num Pub Evacuated 0
Pipe Fac Name Hearne - Frost 10"
Segment Name Line Id 6944
Onshore State Abbreviation Tx
Onshore Postal Code 76666
Onshore City Name Mertens
Onshore County Name Hill
Designated Location Milepost/valve Station
Designated Name 7.4
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 54
Crossing No
Pipe Facility Type Interstate
Item Involved Pipe
Pipe Type Pipe Seam
Pipe Diameter 10
Pipe Wall Thickness 0.203
Pipe Smys 60000
Pipe Specification Api5lx-60
Pipe Seam Type Erw - High Frequency
Pipe Manufacturer Maverick Steel
Pipe Coating Type Fusion Bonded Epoxy(Fbe)
Installation Year 2005
Manufactured Year 2005
Material Involved Carbon Steel
Release Type Leak
Leak Type Crack
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment No
Remediation Ind No
Water Contam Ind No
Could Be Hca Yes
Commodity Reached Hca Yes
Other Pop Ind Yes
Other Pop Yes No Yes
Est Cost Oper Paid 5000
Est Cost Gas Released 4748
Est Cost Prop Damage 30000
Est Cost Emergency 390000
Est Cost Environmental 0
Est Cost Other 0
Prpty 429748
Accident Psig 115
Mop Psig 1440
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Length Segment Isolated 49954
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Cpm In Place Ind Yes
Cpm Operating Ind Yes
Cpm Functional Ind Yes
Cpm Detection Ind No
Cpm Conf Ind No
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details The release volume was below detectable thresholds.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Material Failure Of Pipe Or Weld
Cause Details Original Manufacturing-Related (Not Girth Weld Or Other Welds Formed In The Field)
Field Exam Ind Yes
Failure Type Original Manufacturing-Related (Not Girth Weld Or Other Welds Formed In The Field)
Other Factor Yes
Other Factor Details No Known Contributing Factors
Additional Crack Ind Yes
Collected Data Ind Yes
Emat Ind Yes
Other Tool Tech Ind Yes
Emat Recent Year 2018
Other Tool Tdw Multi-Data Set
Other Recent Year 2018
Has Hydrtst Conduc Before Ind Yes
Hydrtst Most Rcnt Year 2005
Hydrtst Most Rcnt Pressure 2080
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Preparer Name S****** L******
Preparer Title Ai Analyst
Preparer Email S**************@m*********.com
Preparer Telephone 918-574-7327
Preparer Fax 918-574-7376
Prepared Date 2018-09-05 00:00:00
Authorizer Name M*** M******
Authorizer Telephone 918-574-7073
Authorizer Title Mgr Integrity Mgmt And Regulatory Compliance
Authorizer Email M***********@m*********.com
Narrative On 7/18/18, a magellan operator was ground patrolling assets when an area of dead vegetation was observed on the row. At the time of the incident, the frost-hearne line was not running. Operations control was notified and isolation valves on the frost-hearne line were closed. All other magellan pipelines in the area were immediately shut down. Investigative event procedures were implemented and resources responded to the site. Impacted soil was excavated and properly disposed. Field nde indicated the release originated from a crack indication in the erw longitudinal seam. The release was repaired by installation of a type b sleeve. A review of the ultrasonic crack detection inline inspection data was conducted by the ili vendor to identify locations with similar raw data characteristics. Two locations were identified, excavated, and repaired by installation of type b sleeves. 48-hr nrc update: report # 1219024, 7/20/18 15:36 supplemental/final filed updates (09/05/2018 ): part a4, a18 c3a, and part h narrative

All rights reserved. Copyright © by ClearPHMSA