HL incident on 2018-06-23 — TX

Operator
Hiland Crude, Llc
Cause
Equipment Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$3,008
Incident datetime
2018-06-23 07:00
Report number
Location
TX
Narrative
At 7:00 am a hiland crude, llc (hc) operator arrived at trenton station to log daily station readings and observed crude oil in the lined secondary containment. The operator immediately isolated the facilities after verifying that the spill originated from a leaking low pressure charge pump that pulls crude oil from the ship tank into the main line. At 7:10 am operator reported the spill to hc management and initiated internal reporting. The quantity of the spill was estimated to be 75 barrels; requiring a 30-day accident report to PHMSA. No nrc report was required since the accident did not meet any of the criteria in 49cfr part 195.52. The total volume was contained within lined secondary containment with no impact to soil or water resources. A 24 hour notification was provided to the north dakota department of health and environment.
Detailed record list
Report Received Date
2018-07-21 00:00:00
Iyear
2018
Report Number
20180210
Supplemental Number
30680
Report Type
Original Final
Operator Id
Name
Hiland Crude, Llc
Operator Street Address
1001 Louisiana St, Suite 1000
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2018-06-23 07:00:00
Location Latitude
Location Longitude
Commodity Released Type
Crude Oil
Unintentional Release Bbls
75
Recovered Bbls
75
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
Incident Identified Datetime
2018-06-23 07:00:00
System Part Involved
Onshore Terminal/tank Farm Equipment And Piping
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2018-06-23 07:05:00
Restart Datetime
2018-06-23 09:00:00
On Site Datetime
2018-06-23 07:00:00
Nrc Rpt Num
Nrc Notification Not Required
Ignite Ind
No
Explode Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Trenton Station
Segment Name
Trenton Station
Onshore State Abbreviation
Nd
Onshore Postal Code
58801
Onshore City Name
Not Within A Municipality
Onshore County Name
Williams
Designated Location
Milepost/valve Station
Designated Name
68
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Pump
Installation Year
2014
Material Involved
Material Other Than Carbon Steel
Material Details
Pump Bearing Seal Failure
Release Type
Leak
Leak Type
Seal Or Packing
Wildlife Impact Ind
No
Soil Contamination
No
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
0
Est Cost Prop Damage
3008
Est Cost Emergency
4
Est Cost Environmental
0
Est Cost Other
1275
Est Cost Other Details
Clean-Up Cost
Prpty
4287
Accident Psig
40
Mop Psig
285
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
< 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
The investigation conducted by kinder morgan concluded that the reason of the crude oil leak was equipment failure and the controller(s) actions did not contribute to the accident.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Equipment Failure
Cause Details
Pump Or Pump-Related Equipment
Eq Failure Type
Pump Or Pump-Related Equipment
Other Pump Ind
Seal/packing Failure
Additional Thermal Ind
Yes
Preparer Name
J**** L****
Preparer Title
Senior Pipeline Engineer Compliance Codes And Std
Preparer Email
J**********@k***********.com
Preparer Telephone
7016096218
Prepared Date
2018-07-21 00:00:00
Authorizer Name
J**** H********
Authorizer Telephone
7133699443
Authorizer Title
Director Engineering Compliance Codes And Std
Authorizer Email
J**************@k***********.com
Narrative
At 7:00 am a hiland crude, llc (hc) operator arrived at trenton station to log daily station readings and observed crude oil in the lined secondary containment. The operator immediately isolated the facilities after verifying that the spill originated from a leaking low pressure charge pump that pulls crude oil from the ship tank into the main line. At 7:10 am operator reported the spill to hc management and initiated internal reporting. The quantity of the spill was estimated to be 75 barrels; requiring a 30-day accident report to PHMSA. No nrc report was required since the accident did not meet any of the criteria in 49cfr part 195.52. The total volume was contained within lined secondary containment with no impact to soil or water resources. A 24 hour notification was provided to the north dakota department of health and environment.
Report Received Date 2018-07-21 00:00:00
Iyear 2018
Report Number 20180210
Supplemental Number 30680
Report Type Original Final
Operator Id 32619 PHMSA Enforcement
Name Hiland Crude, Llc
Operator Street Address 1001 Louisiana St, Suite 1000
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77002
Local Datetime 2018-06-23 07:00:00
Location Latitude 48.111882 Google Maps OpenStreetMap
Location Longitude -103.771465 Google Maps OpenStreetMap
Commodity Released Type Crude Oil
Unintentional Release Bbls 75
Recovered Bbls 75
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Local Operating Personnel, Including Contractors
Operator Type Operator Employee
Incident Identified Datetime 2018-06-23 07:00:00
System Part Involved Onshore Terminal/tank Farm Equipment And Piping
On Off Shore Onshore
Shutdown Due Accident Ind Yes
Shutdown Datetime 2018-06-23 07:05:00
Restart Datetime 2018-06-23 09:00:00
On Site Datetime 2018-06-23 07:00:00
Nrc Rpt Num Nrc Notification Not Required NRC Report How to search
Ignite Ind No
Explode Ind No
Num Pub Evacuated 0
Pipe Fac Name Trenton Station
Segment Name Trenton Station
Onshore State Abbreviation Nd
Onshore Postal Code 58801
Onshore City Name Not Within A Municipality
Onshore County Name Williams
Designated Location Milepost/valve Station
Designated Name 68
Federal No
Location Type Totally Contained On Operator-Controlled Property
Incident Area Type Aboveground
Incident Area Subtype Typical Aboveground Facility Piping Or Appurtenance
Crossing No
Pipe Facility Type Intrastate
Item Involved Pump
Installation Year 2014
Material Involved Material Other Than Carbon Steel
Material Details Pump Bearing Seal Failure
Release Type Leak
Leak Type Seal Or Packing
Wildlife Impact Ind No
Soil Contamination No
Long Term Assessment No
Remediation Ind No
Water Contam Ind No
Could Be Hca No
Commodity Reached Hca No
Est Cost Oper Paid 0
Est Cost Gas Released 0
Est Cost Prop Damage 3008
Est Cost Emergency 4
Est Cost Environmental 0
Est Cost Other 1275
Est Cost Other Details Clean-Up Cost
Prpty 4287
Accident Psig 40
Mop Psig 285
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Pipeline Function < 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Cpm In Place Ind No
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details The investigation conducted by kinder morgan concluded that the reason of the crude oil leak was equipment failure and the controller(s) actions did not contribute to the accident.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Equipment Failure
Cause Details Pump Or Pump-Related Equipment
Eq Failure Type Pump Or Pump-Related Equipment
Other Pump Ind Seal/packing Failure
Additional Thermal Ind Yes
Preparer Name J**** L****
Preparer Title Senior Pipeline Engineer Compliance Codes And Std
Preparer Email J**********@k***********.com
Preparer Telephone 7016096218
Prepared Date 2018-07-21 00:00:00
Authorizer Name J**** H********
Authorizer Telephone 7133699443
Authorizer Title Director Engineering Compliance Codes And Std
Authorizer Email J**************@k***********.com
Narrative At 7:00 am a hiland crude, llc (hc) operator arrived at trenton station to log daily station readings and observed crude oil in the lined secondary containment. The operator immediately isolated the facilities after verifying that the spill originated from a leaking low pressure charge pump that pulls crude oil from the ship tank into the main line. At 7:10 am operator reported the spill to hc management and initiated internal reporting. The quantity of the spill was estimated to be 75 barrels; requiring a 30-day accident report to PHMSA. No nrc report was required since the accident did not meet any of the criteria in 49cfr part 195.52. The total volume was contained within lined secondary containment with no impact to soil or water resources. A 24 hour notification was provided to the north dakota department of health and environment.

All rights reserved. Copyright © by ClearPHMSA