HL incident on 2018-04-28 — TX

Operator
Valero Partners Operating Co. Llc
Cause
Corrosion Failure
Commodity
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$184,166
Incident datetime
2018-04-28 09:05
Report number
Location
TX
Narrative
A landowner contacted valero about a products odor at 0905 hours on 4/28/2018. The pipeline was down as of 2200 hours on 4/27/2018, with the last shipment being diesel. Local valero personnel arrived at landowners home at 0950 hours on 4/28/2018 and worked on getting to the possible release site. At 1024 hours on 4/27/2018 valero identified the release as associated with the valero line. The valero pipeline was excavated and an indication of a possible pinhole leak was found on 4/28/2017. Valero applied a plidco clamp and the pipeline was restarted at 2254 hours on 4/28/2018 cst. Soil remediation was initiated and an investigation/cutout on the failed pipe will follow in june 2018. Supplemental 6/27/18 - part d remediation costs updated supplemental 8/24/18 - part d estimated costs updated supplemental and final report 12/5/18 - part g external corrosion updated selective seam corrosion as indicated in the incident investigation metallurgy report. Dates of last ili's were also updated in part g to reflect the 2018 assessments.
Detailed record list
Report Received Date
2018-05-25 00:00:00
Iyear
2018
Report Number
20180146
Supplemental Number
31304
Report Type
Supplemental Final
Operator Id
Name
Valero Partners Operating Co. Llc
Operator Street Address
One Valero Way
Operator City Name
San Antonio
Operator State Abbreviation
TX
Operator Postal Code
78249
Local Datetime
2018-04-28 09:05:00
Location Latitude
Location Longitude
-97.11485405
Commodity Released Type
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype
Diesel, Fuel Oil, Kerosene, Jet Fuel
Unintentional Release Bbls
706
Recovered Bbls
706
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Notification From Public
Incident Identified Datetime
2018-04-28 09:05:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2018-04-27 22:00:00
Restart Datetime
2018-04-28 23:00:00
On Site Datetime
2018-04-28 10:24:00
Nrc Rpt Datetime
2018-04-28 10:57:00
Nrc Rpt Num
Ignite Ind
No
Explode Ind
No
Upstream Valve Type Ind
Remotely Controlled
Downstream Valve Type Ind
Manual
Num Pub Evacuated
0
Pipe Fac Name
Ardmore To Wynnewood - 12"
Segment Name
Ardmore To Wynnewood - 12"
Onshore State Abbreviation
Ok
Onshore Postal Code
73401
Onshore City Name
Not Within A Municipality
Onshore County Name
Carter
Designated Location
Survey Station No.
Designated Name
171+98
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
36
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pipe
Pipe Type
Pipe Body
Pipe Diameter
12
Pipe Wall Thickness
0.188
Pipe Smys
42000
Pipe Specification
Api 5lx-42
Pipe Seam Type
Erw - High Frequency
Pipe Manufacturer
American Steel
Pipe Coating Type
Cold Applied Tape
Installation Year
1975
Manufactured Year
1975
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
Yes
Remediation Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
No
Est Cost Oper Paid
46584
Est Cost Gas Released
65234
Est Cost Prop Damage
184166
Est Cost Emergency
107676
Est Cost Environmental
1375023
Est Cost Other
0
Prpty
1778683
Accident Psig
215
Mop Psig
880
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
47767
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
The pipeline was down. The last shipment was completed 4/26/18. Upon excavating the leak site, it appears to be corrosion related.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
External Corrosion
Internal External
External Corrosion
Visual Exam Results
Localized Pitting
Galvanic Corrosion Ind
Yes
Microbiological Corrosion Ind
Yes
Selective Seam Corrosion Ind
Yes
Field Exam Basis Ind
Yes
Underground Location
Yes
Under Cathodic Protection Ind
Yes
Cathodic Pro Start Year
1975
Shielding Evident
Yes
Cathodic Survey Type
Yes
Cp Annual Survey Ind
Yes
Close Interval Survey Ind
Yes
Other Cp Survey Ind
Yes
Cp Annual Survey Year
2017
Close Interval Survey Year
2013
Other Cp Survey Year
2018
Prior Damage
Yes
Collected Data Ind
Yes
Axial Magnetic Flx Lkg Ind
Yes
Geometry Deformation Ind
Yes
Other Tool Tech Ind
Yes
Axial Recent Year
2018
Geometry Recent Year
2018
Other Tool
Mfl-C (Afd)
Other Recent Year
2018
Has Hydrtst Conduc Before Ind
No
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
J**** T******
Preparer Title
Manager Regulatory
Preparer Email
J************@v*****.com
Preparer Telephone
2102191401
Preparer Fax
2103706235
Prepared Date
2018-12-10 00:00:00
Authorizer Name
J**** T******
Authorizer Telephone
2103455145
Authorizer Title
Manager Regulatory
Authorizer Email
J************@v*****.com
Narrative
A landowner contacted valero about a products odor at 0905 hours on 4/28/2018. The pipeline was down as of 2200 hours on 4/27/2018, with the last shipment being diesel. Local valero personnel arrived at landowners home at 0950 hours on 4/28/2018 and worked on getting to the possible release site. At 1024 hours on 4/27/2018 valero identified the release as associated with the valero line. The valero pipeline was excavated and an indication of a possible pinhole leak was found on 4/28/2017. Valero applied a plidco clamp and the pipeline was restarted at 2254 hours on 4/28/2018 cst. Soil remediation was initiated and an investigation/cutout on the failed pipe will follow in june 2018. Supplemental 6/27/18 - part d remediation costs updated supplemental 8/24/18 - part d estimated costs updated supplemental and final report 12/5/18 - part g external corrosion updated selective seam corrosion as indicated in the incident investigation metallurgy report. Dates of last ili's were also updated in part g to reflect the 2018 assessments.
Report Received Date 2018-05-25 00:00:00
Iyear 2018
Report Number 20180146
Supplemental Number 31304
Report Type Supplemental Final
Operator Id 39105 PHMSA Enforcement
Name Valero Partners Operating Co. Llc
Operator Street Address One Valero Way
Operator City Name San Antonio
Operator State Abbreviation TX
Operator Postal Code 78249
Local Datetime 2018-04-28 09:05:00
Location Latitude 34.25315178 Google Maps OpenStreetMap
Location Longitude -97.11485405 Google Maps OpenStreetMap
Commodity Released Type Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype Diesel, Fuel Oil, Kerosene, Jet Fuel
Unintentional Release Bbls 706
Recovered Bbls 706
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Notification From Public
Incident Identified Datetime 2018-04-28 09:05:00
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Shutdown Due Accident Ind Yes
Shutdown Datetime 2018-04-27 22:00:00
Restart Datetime 2018-04-28 23:00:00
On Site Datetime 2018-04-28 10:24:00
Nrc Rpt Datetime 2018-04-28 10:57:00
Nrc Rpt Num 1210583 NRC Report How to search
Ignite Ind No
Explode Ind No
Upstream Valve Type Ind Remotely Controlled
Downstream Valve Type Ind Manual
Num Pub Evacuated 0
Pipe Fac Name Ardmore To Wynnewood - 12"
Segment Name Ardmore To Wynnewood - 12"
Onshore State Abbreviation Ok
Onshore Postal Code 73401
Onshore City Name Not Within A Municipality
Onshore County Name Carter
Designated Location Survey Station No.
Designated Name 171+98
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 36
Crossing No
Pipe Facility Type Interstate
Item Involved Pipe
Pipe Type Pipe Body
Pipe Diameter 12
Pipe Wall Thickness 0.188
Pipe Smys 42000
Pipe Specification Api 5lx-42
Pipe Seam Type Erw - High Frequency
Pipe Manufacturer American Steel
Pipe Coating Type Cold Applied Tape
Installation Year 1975
Manufactured Year 1975
Material Involved Carbon Steel
Release Type Leak
Leak Type Pinhole
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment Yes
Remediation Ind Yes
Soil Remed Ind Yes
Water Contam Ind No
Could Be Hca Yes
Commodity Reached Hca No
Est Cost Oper Paid 46584
Est Cost Gas Released 65234
Est Cost Prop Damage 184166
Est Cost Emergency 107676
Est Cost Environmental 1375023
Est Cost Other 0
Prpty 1778683
Accident Psig 215
Mop Psig 880
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Length Segment Isolated 47767
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Cpm In Place Ind Yes
Cpm Operating Ind Yes
Cpm Functional Ind Yes
Cpm Detection Ind No
Cpm Conf Ind No
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details The pipeline was down. The last shipment was completed 4/26/18. Upon excavating the leak site, it appears to be corrosion related.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Corrosion Failure
Cause Details External Corrosion
Internal External External Corrosion
Visual Exam Results Localized Pitting
Galvanic Corrosion Ind Yes
Microbiological Corrosion Ind Yes
Selective Seam Corrosion Ind Yes
Field Exam Basis Ind Yes
Underground Location Yes
Under Cathodic Protection Ind Yes
Cathodic Pro Start Year 1975
Shielding Evident Yes
Cathodic Survey Type Yes
Cp Annual Survey Ind Yes
Close Interval Survey Ind Yes
Other Cp Survey Ind Yes
Cp Annual Survey Year 2017
Close Interval Survey Year 2013
Other Cp Survey Year 2018
Prior Damage Yes
Collected Data Ind Yes
Axial Magnetic Flx Lkg Ind Yes
Geometry Deformation Ind Yes
Other Tool Tech Ind Yes
Axial Recent Year 2018
Geometry Recent Year 2018
Other Tool Mfl-C (Afd)
Other Recent Year 2018
Has Hydrtst Conduc Before Ind No
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Preparer Name J**** T******
Preparer Title Manager Regulatory
Preparer Email J************@v*****.com
Preparer Telephone 2102191401
Preparer Fax 2103706235
Prepared Date 2018-12-10 00:00:00
Authorizer Name J**** T******
Authorizer Telephone 2103455145
Authorizer Title Manager Regulatory
Authorizer Email J************@v*****.com
Narrative A landowner contacted valero about a products odor at 0905 hours on 4/28/2018. The pipeline was down as of 2200 hours on 4/27/2018, with the last shipment being diesel. Local valero personnel arrived at landowners home at 0950 hours on 4/28/2018 and worked on getting to the possible release site. At 1024 hours on 4/27/2018 valero identified the release as associated with the valero line. The valero pipeline was excavated and an indication of a possible pinhole leak was found on 4/28/2017. Valero applied a plidco clamp and the pipeline was restarted at 2254 hours on 4/28/2018 cst. Soil remediation was initiated and an investigation/cutout on the failed pipe will follow in june 2018. Supplemental 6/27/18 - part d remediation costs updated supplemental 8/24/18 - part d estimated costs updated supplemental and final report 12/5/18 - part g external corrosion updated selective seam corrosion as indicated in the incident investigation metallurgy report. Dates of last ili's were also updated in part g to reflect the 2018 assessments.