Incident details
Operator, cause, commodity and consequences with raw source fields.
GD incident on 2018-11-25 — NY
Operator
Consolidated Edison Co Of New York
Cause
Other Outside Force Damage
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$5,000
Incident datetime
2018-11-25 16:44
Report number
Location
NY, NEW YORK
Narrative
On november 25, 2018, at 16:44, con edison's gas emergency response center (gerc) received a report from the fire department of the city of new york (fdny) of an electrical fire at 2465 broadway in manhattan. The fdny reported that the fire was producing elevated levels of carbon monoxide (co) and that onsite fdny personnel had detected co in front of the building, which contains a large equinox gym. At 16:45, con edison's gerc dispatched a mechanic to the location from its gas distribution services (gds) department. Prior to the gds mechanic's arrival, the fdny evacuated an unknown number of occupants from buildings along the west side of broadway between west 91st and west 92nd streets due to the co condition. The con edison gds mechanic arrived on location at 17:17 and began to investigate. At 17:34, the gds mechanic reported a 50% natural gas reading five feet from the foundation wall of the building at 2465 broadway. There was no access into the building at that time due to the co condition. A multiple resource response event (code murre) was then initiated by con edison due to the combined involvement of both electric and gas. Additional con edison gas emergency responders were then dispatched to the location. At 18:17, the gds mechanic reported that an explosion occurred inside the equinox gym, shattering the building's windows. The gerc then dispatched additional con edison gas personnel to the location to provide assistance. At 18:34, onsite gds personnel reported having no access to the curb valve on the gas service line supplying 2465 broadway due to unsafe conditions in the sidewalk area related to an apparent underground electric cable burnout. By 20:39, con edison personnel closed three low-pressure main valves to isolate the area, which interrupted gas service to nine buildings and 538 customers. In addition, con edison electric operations personnel de-energized the electric supply on the west side of broadway between west 91st and west 92nd streets, and confirmed that an underground electric cable burnout had occurred in the area in front of 2465 broadway.At 21:47, con edison personnel reported, per the onsite fdny battalion chief,that a suspected natural gas ignition had occurred inside of the equinox gym. The fdny also reported detecting 3.5 percent natural gas-in-air (70 percent of the lower explosive limit) inside the building's basement staircase prior to the explosion.Con edison gds personnel then gained access to the building and detected 0.2 percent natural gas-in-air at the foundation wall in the basement in the vicinity of the gas meter, which quickly vented to 0 percent.The gas piping inside the basement at the gas meter was found intact. By 22:45, the fdny terminated all evacuations except for the affected building at 2465 broadway. The area is supplied by an 8-inch and 6-inch low-pressure polyethylene (lppe) gas main, with a 4-inch lppe gas service supplying the building at 2465 broadway.Con edison checked odorant levels and distribution system pressure supplying the area after the incident and found both to be within acceptable ranges. On november 26, 2018, at 10:56, a baseball-sized hole was found in the 6-inch lppe gas main in front of 2465 broadway. The hole appeared to have been created by the electric cable burnout that had occurred in that area. The affected section of 6-inch lppe gas main was cut out and capped, and the three closed main valves were re-opened, restoring gas supply in the affected area.Subsequent leak surveys conducted in the area identified two gas leak (a type 1 leak in front of 256 west 92nd street and a type 3 leak in front of 251 west 92nd street).Con edison pinpointed and repaired both leaks. As a result of the explosion, one con edison employee was taken to mt. Sinai medical center, where he was evaluated and released. No other injuries were reported.Multiple media outlets and agencies were on location.Nyspsc, nycdep,and usdot were notified.
Detailed record list
Occurred At
2018-11-25 16:44:00
Year
2018
Report Received Date
2018-12-24 00:00:00
Iyear
2018.0
Report Number
20180124.0
Supplemental Number
31410.0
Report Type
Supplemental Final
Operator Id
2704
Name
Consolidated Edison Co Of New York
Operator Street Address
4 Irving Place
Operator City Name
New York
Operator State Abbreviation
NY
Operator Postal Code
10003
Local Datetime
2018-11-25 18:17:00
Location Street Address
2465 Broadway
Location City Name
New York
Location County Name
New York
Location State Abbreviation
NY
Location Postal Code
10025
Location Latitude
40.79198
Location Longitude
-73.97437
Nrc Rpt Datetime
2018-11-25 22:26:00
Nrc Rpt Num
1231251
Commodity Released Type
Natural Gas
Unintentional Release
6.0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Ignite Ind
Yes
Explode Ind
Yes
Num Pub Evacuated
50.0
Incident Identified Datetime
2018-11-25 16:44:00
On Site Datetime
2018-11-25 17:17:00
Federal
No
Location Type
Public Property
Incident Area Type
Underground
Incident Area Subtype
Under Pavement
Depth Of Cover
37.0
Crossing
No
Pipe Facility Type
Privately Owned
System Part Involved
Main
Installation Year
2015.0
Pipe Diameter
6.0
Pipe Specification
Pe
Pipe Manufacturer
Unknown
Material Involved
Plastic
Plastic Type
Polyethylene (Pe)
Wt Plastic Unknown Ind
Unknown
Material Pe Pipe Code
Unknown
Release Type
Leak
Leak Type
Other
Leak Type Other
Electric Burnout Caused Leak
Class Location Type
Class 4 Location
Est Cost Oper Paid
250000.0
Est Cost Prop Damage
5000.0
Est Cost Emergency
38400.0
Est Cost Other
500.0
Est Cost Other Details
Materials
Est Cost Unintentional Release
14.0
Prpty
293914.0
Commercial Affected
4.0
Industrial Affected
0.0
Residences Affected
534.0
Accident Psig
0.25
Normal Psig
0.25
Mop Psig
0.5
Accident Pressure
Pressure Did Not Exceed Maop
Scada In Place Ind
No
Accident Identifier
Notification From Emergency Responder
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind
Yes
Num Employees Tested
1
Num Employees Failed
0
Contractor Drug Test Ind
No
Cause
Other Outside Force Damage
Cause Details
Electrical Arcing From Other Equipment Or Facility
Outside Force Type
Electrical Arcing From Other Equipment Or Facility
Preparer Name
O**** L***
Preparer Title
Gas Emergency Response Center-Operations Manager
Preparer Email
L****@c****.com
Preparer Telephone
718-319-2310
Preparer Fax
718-824-2219
Authorizer Name
N******* H*****
Authorizer Title
Gas Emergency Response Center-Department Manager
Authorizer Telephone
718-319-2350
Authorizer Email
H******@c****.com
Narrative
On november 25, 2018, at 16:44, con edison's gas emergency response center (gerc) received a report from the fire department of the city of new york (fdny) of an electrical fire at 2465 broadway in manhattan. The fdny reported that the fire was producing elevated levels of carbon monoxide (co) and that onsite fdny personnel had detected co in front of the building, which contains a large equinox gym. At 16:45, con edison's gerc dispatched a mechanic to the location from its gas distribution services (gds) department. Prior to the gds mechanic's arrival, the fdny evacuated an unknown number of occupants from buildings along the west side of broadway between west 91st and west 92nd streets due to the co condition. The con edison gds mechanic arrived on location at 17:17 and began to investigate. At 17:34, the gds mechanic reported a 50% natural gas reading five feet from the foundation wall of the building at 2465 broadway. There was no access into the building at that time due to the co condition. A multiple resource response event (code murre) was then initiated by con edison due to the combined involvement of both electric and gas. Additional con edison gas emergency responders were then dispatched to the location. At 18:17, the gds mechanic reported that an explosion occurred inside the equinox gym, shattering the building's windows. The gerc then dispatched additional con edison gas personnel to the location to provide assistance. At 18:34, onsite gds personnel reported having no access to the curb valve on the gas service line supplying 2465 broadway due to unsafe conditions in the sidewalk area related to an apparent underground electric cable burnout. By 20:39, con edison personnel closed three low-pressure main valves to isolate the area, which interrupted gas service to nine buildings and 538 customers. In addition, con edison electric operations personnel de-energized the electric supply on the west side of broadway between west 91st and west 92nd streets, and confirmed that an underground electric cable burnout had occurred in the area in front of 2465 broadway.At 21:47, con edison personnel reported, per the onsite fdny battalion chief,that a suspected natural gas ignition had occurred inside of the equinox gym. The fdny also reported detecting 3.5 percent natural gas-in-air (70 percent of the lower explosive limit) inside the building's basement staircase prior to the explosion.Con edison gds personnel then gained access to the building and detected 0.2 percent natural gas-in-air at the foundation wall in the basement in the vicinity of the gas meter, which quickly vented to 0 percent.The gas piping inside the basement at the gas meter was found intact. By 22:45, the fdny terminated all evacuations except for the affected building at 2465 broadway. The area is supplied by an 8-inch and 6-inch low-pressure polyethylene (lppe) gas main, with a 4-inch lppe gas service supplying the building at 2465 broadway.Con edison checked odorant levels and distribution system pressure supplying the area after the incident and found both to be within acceptable ranges. On november 26, 2018, at 10:56, a baseball-sized hole was found in the 6-inch lppe gas main in front of 2465 broadway. The hole appeared to have been created by the electric cable burnout that had occurred in that area. The affected section of 6-inch lppe gas main was cut out and capped, and the three closed main valves were re-opened, restoring gas supply in the affected area.Subsequent leak surveys conducted in the area identified two gas leak (a type 1 leak in front of 256 west 92nd street and a type 3 leak in front of 251 west 92nd street).Con edison pinpointed and repaired both leaks. As a result of the explosion, one con edison employee was taken to mt. Sinai medical center, where he was evaluated and released. No other injuries were reported.Multiple media outlets and agencies were on location.Nyspsc, nycdep,and usdot were notified.
| Occurred At | 2018-11-25 16:44:00 |
|---|---|
| Year | 2018 |
| Report Received Date | 2018-12-24 00:00:00 |
| Iyear | 2018.0 |
| Report Number | 20180124.0 |
| Supplemental Number | 31410.0 |
| Report Type | Supplemental Final |
| Operator Id | 2704 PHMSA Enforcement |
| Name | Consolidated Edison Co Of New York |
| Operator Street Address | 4 Irving Place |
| Operator City Name | New York |
| Operator State Abbreviation | NY |
| Operator Postal Code | 10003 |
| Local Datetime | 2018-11-25 18:17:00 |
| Location Street Address | 2465 Broadway |
| Location City Name | New York |
| Location County Name | New York |
| Location State Abbreviation | NY |
| Location Postal Code | 10025 |
| Location Latitude | 40.79198 Google Maps OpenStreetMap |
| Location Longitude | -73.97437 Google Maps OpenStreetMap |
| Nrc Rpt Datetime | 2018-11-25 22:26:00 |
| Nrc Rpt Num | 1231251 NRC Report How to search |
| Commodity Released Type | Natural Gas |
| Unintentional Release | 6.0 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Ignite Ind | Yes |
| Explode Ind | Yes |
| Num Pub Evacuated | 50.0 |
| Incident Identified Datetime | 2018-11-25 16:44:00 |
| On Site Datetime | 2018-11-25 17:17:00 |
| Federal | No |
| Location Type | Public Property |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Pavement |
| Depth Of Cover | 37.0 |
| Crossing | No |
| Pipe Facility Type | Privately Owned |
| System Part Involved | Main |
| Installation Year | 2015.0 |
| Pipe Diameter | 6.0 |
| Pipe Specification | Pe |
| Pipe Manufacturer | Unknown |
| Material Involved | Plastic |
| Plastic Type | Polyethylene (Pe) |
| Wt Plastic Unknown Ind | Unknown |
| Material Pe Pipe Code | Unknown |
| Release Type | Leak |
| Leak Type | Other |
| Leak Type Other | Electric Burnout Caused Leak |
| Class Location Type | Class 4 Location |
| Est Cost Oper Paid | 250000.0 |
| Est Cost Prop Damage | 5000.0 |
| Est Cost Emergency | 38400.0 |
| Est Cost Other | 500.0 |
| Est Cost Other Details | Materials |
| Est Cost Unintentional Release | 14.0 |
| Prpty | 293914.0 |
| Commercial Affected | 4.0 |
| Industrial Affected | 0.0 |
| Residences Affected | 534.0 |
| Accident Psig | 0.25 |
| Normal Psig | 0.25 |
| Mop Psig | 0.5 |
| Accident Pressure | Pressure Did Not Exceed Maop |
| Scada In Place Ind | No |
| Accident Identifier | Notification From Emergency Responder |
| Investigation Status | No, the facility was not monitored by a controller(s) at the time of the incident |
| Employee Drug Test Ind | Yes |
| Num Employees Tested | 1 |
| Num Employees Failed | 0 |
| Contractor Drug Test Ind | No |
| Cause | Other Outside Force Damage |
| Cause Details | Electrical Arcing From Other Equipment Or Facility |
| Outside Force Type | Electrical Arcing From Other Equipment Or Facility |
| Preparer Name | O**** L*** |
| Preparer Title | Gas Emergency Response Center-Operations Manager |
| Preparer Email | L****@c****.com |
| Preparer Telephone | 718-319-2310 |
| Preparer Fax | 718-824-2219 |
| Authorizer Name | N******* H***** |
| Authorizer Title | Gas Emergency Response Center-Department Manager |
| Authorizer Telephone | 718-319-2350 |
| Authorizer Email | H******@c****.com |
| Narrative | On november 25, 2018, at 16:44, con edison's gas emergency response center (gerc) received a report from the fire department of the city of new york (fdny) of an electrical fire at 2465 broadway in manhattan. The fdny reported that the fire was producing elevated levels of carbon monoxide (co) and that onsite fdny personnel had detected co in front of the building, which contains a large equinox gym. At 16:45, con edison's gerc dispatched a mechanic to the location from its gas distribution services (gds) department. Prior to the gds mechanic's arrival, the fdny evacuated an unknown number of occupants from buildings along the west side of broadway between west 91st and west 92nd streets due to the co condition. The con edison gds mechanic arrived on location at 17:17 and began to investigate. At 17:34, the gds mechanic reported a 50% natural gas reading five feet from the foundation wall of the building at 2465 broadway. There was no access into the building at that time due to the co condition. A multiple resource response event (code murre) was then initiated by con edison due to the combined involvement of both electric and gas. Additional con edison gas emergency responders were then dispatched to the location. At 18:17, the gds mechanic reported that an explosion occurred inside the equinox gym, shattering the building's windows. The gerc then dispatched additional con edison gas personnel to the location to provide assistance. At 18:34, onsite gds personnel reported having no access to the curb valve on the gas service line supplying 2465 broadway due to unsafe conditions in the sidewalk area related to an apparent underground electric cable burnout. By 20:39, con edison personnel closed three low-pressure main valves to isolate the area, which interrupted gas service to nine buildings and 538 customers. In addition, con edison electric operations personnel de-energized the electric supply on the west side of broadway between west 91st and west 92nd streets, and confirmed that an underground electric cable burnout had occurred in the area in front of 2465 broadway.At 21:47, con edison personnel reported, per the onsite fdny battalion chief,that a suspected natural gas ignition had occurred inside of the equinox gym. The fdny also reported detecting 3.5 percent natural gas-in-air (70 percent of the lower explosive limit) inside the building's basement staircase prior to the explosion.Con edison gds personnel then gained access to the building and detected 0.2 percent natural gas-in-air at the foundation wall in the basement in the vicinity of the gas meter, which quickly vented to 0 percent.The gas piping inside the basement at the gas meter was found intact. By 22:45, the fdny terminated all evacuations except for the affected building at 2465 broadway. The area is supplied by an 8-inch and 6-inch low-pressure polyethylene (lppe) gas main, with a 4-inch lppe gas service supplying the building at 2465 broadway.Con edison checked odorant levels and distribution system pressure supplying the area after the incident and found both to be within acceptable ranges. On november 26, 2018, at 10:56, a baseball-sized hole was found in the 6-inch lppe gas main in front of 2465 broadway. The hole appeared to have been created by the electric cable burnout that had occurred in that area. The affected section of 6-inch lppe gas main was cut out and capped, and the three closed main valves were re-opened, restoring gas supply in the affected area.Subsequent leak surveys conducted in the area identified two gas leak (a type 1 leak in front of 256 west 92nd street and a type 3 leak in front of 251 west 92nd street).Con edison pinpointed and repaired both leaks. As a result of the explosion, one con edison employee was taken to mt. Sinai medical center, where he was evaluated and released. No other injuries were reported.Multiple media outlets and agencies were on location.Nyspsc, nycdep,and usdot were notified. |