HL incident on 2017-12-03 — TX
Operator
Enterprise Crude Pipeline Llc
Cause
Equipment Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$0
Incident datetime
2017-12-03 14:30
Report number
Location
TX
Narrative
On 12-3-17 at approximately 1430 local operating personnel discovered crude oil near the flow switch for the midland to sealy mainline units. The movement was immediately shutdown and clean-up started. The flow switch was removed from service and will not be reinstalled.
Detailed record list
Report Received Date
2017-12-18 00:00:00
Iyear
2017
Report Number
20170419
Supplemental Number
22960
Report Type
Original Final
Operator Id
30829
Name
Enterprise Crude Pipeline Llc
Operator Street Address
1100 Louisiana Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2017-12-03 14:30:00
Location Latitude
32.021719
Location Longitude
-102.016295
Commodity Released Type
Crude Oil
Unintentional Release Bbls
20
Recovered Bbls
20
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
Incident Identified Datetime
2017-12-03 14:30:00
System Part Involved
Onshore Terminal/tank Farm Equipment And Piping
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2017-12-03 14:30:00
Restart Datetime
2017-12-03 18:30:00
On Site Datetime
2017-12-03 14:30:00
Nrc Rpt Num
Nrc Notification Not Required
Ignite Ind
No
Explode Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Midland Station
Segment Name
Midland-Sealy Ml Unit
Onshore State Abbreviation
Tx
Onshore Postal Code
79706
Onshore City Name
Midland
Onshore County Name
Midalnd
Designated Location
Milepost/valve Station
Designated Name
Midland Stat
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Instrumentation
Installation Year
2017
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Connection Failure
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
1000
Est Cost Prop Damage
0
Est Cost Emergency
15000
Est Cost Environmental
0
Est Cost Other
0
Prpty
16000
Accident Psig
950
Mop Psig
1480
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Controller nor control room were a contributing factor
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Equipment Failure
Cause Details
Non-Threaded Connection Failure
Eq Failure Type
Non-Threaded Connection Failure
Other Non Threaded Ind
Other
Other Non Threaded Details
Flow Switch
Eq Additional Other Ind
Yes
Eq Additional Other Details
Mechanical Failure
Preparer Name
C**** A******
Preparer Title
Pipeline Compliance
Preparer Email
C*******@e****.com
Preparer Telephone
713-381-6426
Prepared Date
2017-12-18 00:00:00
Authorizer Name
C**** A******
Authorizer Telephone
713-381-6426
Authorizer Email
C*******@e****.com
Narrative
On 12-3-17 at approximately 1430 local operating personnel discovered crude oil near the flow switch for the midland to sealy mainline units. The movement was immediately shutdown and clean-up started. The flow switch was removed from service and will not be reinstalled.
| Report Received Date | 2017-12-18 00:00:00 |
|---|---|
| Iyear | 2017 |
| Report Number | 20170419 |
| Supplemental Number | 22960 |
| Report Type | Original Final |
| Operator Id | 30829 PHMSA Enforcement |
| Name | Enterprise Crude Pipeline Llc |
| Operator Street Address | 1100 Louisiana Street |
| Operator City Name | Houston |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77002 |
| Local Datetime | 2017-12-03 14:30:00 |
| Location Latitude | 32.021719 Google Maps OpenStreetMap |
| Location Longitude | -102.016295 Google Maps OpenStreetMap |
| Commodity Released Type | Crude Oil |
| Unintentional Release Bbls | 20 |
| Recovered Bbls | 20 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Local Operating Personnel, Including Contractors |
| Operator Type | Operator Employee |
| Incident Identified Datetime | 2017-12-03 14:30:00 |
| System Part Involved | Onshore Terminal/tank Farm Equipment And Piping |
| On Off Shore | Onshore |
| Shutdown Due Accident Ind | Yes |
| Shutdown Datetime | 2017-12-03 14:30:00 |
| Restart Datetime | 2017-12-03 18:30:00 |
| On Site Datetime | 2017-12-03 14:30:00 |
| Nrc Rpt Num | Nrc Notification Not Required NRC Report How to search |
| Ignite Ind | No |
| Explode Ind | No |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Midland Station |
| Segment Name | Midland-Sealy Ml Unit |
| Onshore State Abbreviation | Tx |
| Onshore Postal Code | 79706 |
| Onshore City Name | Midland |
| Onshore County Name | Midalnd |
| Designated Location | Milepost/valve Station |
| Designated Name | Midland Stat |
| Federal | No |
| Location Type | Totally Contained On Operator-Controlled Property |
| Incident Area Type | Aboveground |
| Incident Area Subtype | Typical Aboveground Facility Piping Or Appurtenance |
| Crossing | No |
| Pipe Facility Type | Intrastate |
| Item Involved | Instrumentation |
| Installation Year | 2017 |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Connection Failure |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | No |
| Remediation Ind | No |
| Water Contam Ind | No |
| Could Be Hca | No |
| Commodity Reached Hca | No |
| Est Cost Oper Paid | 0 |
| Est Cost Gas Released | 1000 |
| Est Cost Prop Damage | 0 |
| Est Cost Emergency | 15000 |
| Est Cost Environmental | 0 |
| Est Cost Other | 0 |
| Prpty | 16000 |
| Accident Psig | 950 |
| Mop Psig | 1480 |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | No |
| Cpm In Place Ind | No |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | Controller nor control room were a contributing factor |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Equipment Failure |
| Cause Details | Non-Threaded Connection Failure |
| Eq Failure Type | Non-Threaded Connection Failure |
| Other Non Threaded Ind | Other |
| Other Non Threaded Details | Flow Switch |
| Eq Additional Other Ind | Yes |
| Eq Additional Other Details | Mechanical Failure |
| Preparer Name | C**** A****** |
| Preparer Title | Pipeline Compliance |
| Preparer Email | C*******@e****.com |
| Preparer Telephone | 713-381-6426 |
| Prepared Date | 2017-12-18 00:00:00 |
| Authorizer Name | C**** A****** |
| Authorizer Telephone | 713-381-6426 |
| Authorizer Email | C*******@e****.com |
| Narrative | On 12-3-17 at approximately 1430 local operating personnel discovered crude oil near the flow switch for the midland to sealy mainline units. The movement was immediately shutdown and clean-up started. The flow switch was removed from service and will not be reinstalled. |