HL incident on 2017-11-27 — PA

Operator
Buckeye Partners, Lp
Cause
Excavation Issue
Commodity
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$95,000
Incident datetime
2017-11-27 07:00
Report number
Location
PA
Narrative
At approx. 0700 hrs. 11/27/17 buckeye received a call from the facility owner stating that while they were performing rounds they discovered stained stone and believed there was a leak on their property but the source was unknown. All internal notifications were conducted. Buckeye personnel arrived on site at 0830 hrs., upon arrival shell had a vacuum truck and small crew who had all free product removed. In an abundance of caution, buckeye personnel placed a call to the nrc to report a leak with the source still being unknown. The facility owner and buckeye operations began hand excavation to locate the source. Excavation of line sa604pr and visual examination determined the source of the spill to be buckeyes line. A second call was made to the nrc to provide an update to the original report (#1198306) a visual inspection identified a gouge feature located at the 11 o'clock position on the pipe. It appears excavation equipment or other mechanical digging equipment had previously caused damage to the pipe. A high pressure pipeline repair (plidco) clamp was installed. The investigation is on-going. Update 7/18/2018 - the section of damaged pipe will be cut out and sent for metallurgic analysis to confirm the third party strike.
Detailed record list
Report Received Date
2017-12-15 00:00:00
Iyear
2017
Report Number
20170415
Supplemental Number
30659
Report Type
Supplemental Final
Operator Id
Name
Buckeye Partners, Lp
Operator Street Address
The Buckeye Building 6161 Hamilton Boulevar
Operator City Name
Allentown
Operator State Abbreviation
PA
Operator Postal Code
18106
Local Datetime
2017-11-27 07:00:00
Location Latitude
Location Longitude
-74.26054003
Commodity Released Type
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype
Diesel, Fuel Oil, Kerosene, Jet Fuel
Unintentional Release Bbls
0.38
Recovered Bbls
0.38
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
Incident Identified Datetime
2017-11-27 07:00:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Shutdown Due Accident Ind
No
Shutdown Explain
The Line Was Not Active At The Time Of The Incident
On Site Datetime
2017-11-27 07:00:00
Nrc Rpt Datetime
2017-11-27 09:45:00
Nrc Rpt Num
Ignite Ind
No
Explode Ind
No
Upstream Valve Type Ind
Manual
Downstream Valve Type Ind
Manual
Num Pub Evacuated
0
Pipe Fac Name
Sa604pr
Segment Name
Sa604pr
Onshore State Abbreviation
Nj
Onshore Postal Code
07077
Onshore City Name
Sewaren
Onshore County Name
Middlesex
Designated Location
Milepost/valve Station
Designated Name
26579 - 27178
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
30
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pipe
Pipe Type
Pipe Body
Pipe Diameter
12.75
Pipe Wall Thickness
0.25
Pipe Smys
Unknown
Pipe Specification
Api 5l
Pipe Seam Type
Seamless
Pipe Manufacturer
Unknown
Pipe Coating Type
Coal Tar
Installation Year
Unknown
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
0
Est Cost Prop Damage
95000
Est Cost Emergency
15600
Est Cost Environmental
70000
Est Cost Other
0
Prpty
180600
Accident Psig
100
Mop Psig
717
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
325
Internal Inspection Ind
No
Unsuitable Mainline Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Amount of release was not significant enough to be detected through mechanical measures.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Excavation Damage
Cause Details
Previous Damage Due To Excavation Activity
Ex Party Type
Previous Damage Due To Excavation Activity
Notify Cga Dirt
Yes
Pipeline Easement Row Ind
Yes
Excavator Type
Unknown/other
Excavator Equipment
Unknown/other
Work Performed
Unknown/other
One Call Notified Ind
No
Root Cause Category
Excavation Issue
Root Cause Type
Excavator Failed To Maintain Clearance After Verifying Marks
Collected Data Ind
No
Insp Compl Before Damage Ind
No
Has Hydrtst Conduc Before Ind
No
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
D*** C*****
Preparer Title
Specialist District Compliance
Preparer Email
D******@b******.com
Preparer Telephone
484 707 1426
Prepared Date
2018-07-19 00:00:00
Authorizer Name
C****** P********
Authorizer Telephone
610 904 4113
Authorizer Title
Director Regulatory Compliance
Authorizer Email
C*********@b******.com
Narrative
At approx. 0700 hrs. 11/27/17 buckeye received a call from the facility owner stating that while they were performing rounds they discovered stained stone and believed there was a leak on their property but the source was unknown. All internal notifications were conducted. Buckeye personnel arrived on site at 0830 hrs., upon arrival shell had a vacuum truck and small crew who had all free product removed. In an abundance of caution, buckeye personnel placed a call to the nrc to report a leak with the source still being unknown. The facility owner and buckeye operations began hand excavation to locate the source. Excavation of line sa604pr and visual examination determined the source of the spill to be buckeyes line. A second call was made to the nrc to provide an update to the original report (#1198306) a visual inspection identified a gouge feature located at the 11 o'clock position on the pipe. It appears excavation equipment or other mechanical digging equipment had previously caused damage to the pipe. A high pressure pipeline repair (plidco) clamp was installed. The investigation is on-going. Update 7/18/2018 - the section of damaged pipe will be cut out and sent for metallurgic analysis to confirm the third party strike.
Report Received Date 2017-12-15 00:00:00
Iyear 2017
Report Number 20170415
Supplemental Number 30659
Report Type Supplemental Final
Operator Id 1845 PHMSA Enforcement
Name Buckeye Partners, Lp
Operator Street Address The Buckeye Building 6161 Hamilton Boulevar
Operator City Name Allentown
Operator State Abbreviation PA
Operator Postal Code 18106
Local Datetime 2017-11-27 07:00:00
Location Latitude 40.54894482 Google Maps OpenStreetMap
Location Longitude -74.26054003 Google Maps OpenStreetMap
Commodity Released Type Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype Diesel, Fuel Oil, Kerosene, Jet Fuel
Unintentional Release Bbls 0.38
Recovered Bbls 0.38
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Local Operating Personnel, Including Contractors
Operator Type Operator Employee
Incident Identified Datetime 2017-11-27 07:00:00
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Shutdown Due Accident Ind No
Shutdown Explain The Line Was Not Active At The Time Of The Incident
On Site Datetime 2017-11-27 07:00:00
Nrc Rpt Datetime 2017-11-27 09:45:00
Nrc Rpt Num 1198163 NRC Report How to search
Ignite Ind No
Explode Ind No
Upstream Valve Type Ind Manual
Downstream Valve Type Ind Manual
Num Pub Evacuated 0
Pipe Fac Name Sa604pr
Segment Name Sa604pr
Onshore State Abbreviation Nj
Onshore Postal Code 07077
Onshore City Name Sewaren
Onshore County Name Middlesex
Designated Location Milepost/valve Station
Designated Name 26579 - 27178
Federal No
Location Type Totally Contained On Operator-Controlled Property
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 30
Crossing No
Pipe Facility Type Interstate
Item Involved Pipe
Pipe Type Pipe Body
Pipe Diameter 12.75
Pipe Wall Thickness 0.25
Pipe Smys Unknown
Pipe Specification Api 5l
Pipe Seam Type Seamless
Pipe Manufacturer Unknown
Pipe Coating Type Coal Tar
Installation Year Unknown
Manufactured Year Unknown
Material Involved Carbon Steel
Release Type Leak
Leak Type Pinhole
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment No
Remediation Ind No
Water Contam Ind No
Could Be Hca Yes
Commodity Reached Hca No
Est Cost Oper Paid 0
Est Cost Gas Released 0
Est Cost Prop Damage 95000
Est Cost Emergency 15600
Est Cost Environmental 70000
Est Cost Other 0
Prpty 180600
Accident Psig 100
Mop Psig 717
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Length Segment Isolated 325
Internal Inspection Ind No
Unsuitable Mainline Ind Yes
Operation Complications Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Cpm In Place Ind Yes
Cpm Operating Ind Yes
Cpm Functional Ind Yes
Cpm Detection Ind No
Cpm Conf Ind No
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details Amount of release was not significant enough to be detected through mechanical measures.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Excavation Damage
Cause Details Previous Damage Due To Excavation Activity
Ex Party Type Previous Damage Due To Excavation Activity
Notify Cga Dirt Yes
Pipeline Easement Row Ind Yes
Excavator Type Unknown/other
Excavator Equipment Unknown/other
Work Performed Unknown/other
One Call Notified Ind No
Root Cause Category Excavation Issue
Root Cause Type Excavator Failed To Maintain Clearance After Verifying Marks
Collected Data Ind No
Insp Compl Before Damage Ind No
Has Hydrtst Conduc Before Ind No
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Preparer Name D*** C*****
Preparer Title Specialist District Compliance
Preparer Email D******@b******.com
Preparer Telephone 484 707 1426
Prepared Date 2018-07-19 00:00:00
Authorizer Name C****** P********
Authorizer Telephone 610 904 4113
Authorizer Title Director Regulatory Compliance
Authorizer Email C*********@b******.com
Narrative At approx. 0700 hrs. 11/27/17 buckeye received a call from the facility owner stating that while they were performing rounds they discovered stained stone and believed there was a leak on their property but the source was unknown. All internal notifications were conducted. Buckeye personnel arrived on site at 0830 hrs., upon arrival shell had a vacuum truck and small crew who had all free product removed. In an abundance of caution, buckeye personnel placed a call to the nrc to report a leak with the source still being unknown. The facility owner and buckeye operations began hand excavation to locate the source. Excavation of line sa604pr and visual examination determined the source of the spill to be buckeyes line. A second call was made to the nrc to provide an update to the original report (#1198306) a visual inspection identified a gouge feature located at the 11 o'clock position on the pipe. It appears excavation equipment or other mechanical digging equipment had previously caused damage to the pipe. A high pressure pipeline repair (plidco) clamp was installed. The investigation is on-going. Update 7/18/2018 - the section of damaged pipe will be cut out and sent for metallurgic analysis to confirm the third party strike.

All rights reserved. Copyright © by ClearPHMSA