Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2017-07-07 — TX
Operator
Exxonmobil Pipeline Co
Cause
Material Failure Of Pipe Or Weld
Commodity
Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$40,000
Incident datetime
2017-07-07 09:15
Report number
Location
TX
Narrative
On 7/7/2017 a small pinhole was discovered on the bottom of a pipe girth weld connected to a 4" tee located on the sorrento dome propane pipeline manifold between the meters and the storage well. The manifold and associated pipeline was bypassed until repairs were made. Non-destructive x-ray tests determined a faulty weld was the cause of the release. Upon inspection, the cause of the leak was visually verified to be a pinhole due to an incomplete final pass at a girth weld at the 6 o'clock position of a welded tee. Nde found the base pipe material to be competent. Hc manifold is estimated to have been fabricated in the 1950s
Detailed record list
Report Received Date
2017-08-04 00:00:00
Iyear
2017
Report Number
20170237
Supplemental Number
30043
Report Type
Supplemental Final
Operator Id
4906
Name
Exxonmobil Pipeline Co
Operator Street Address
22777 Springwoods Village Parkway E2.2b-Emp
Operator City Name
Spring
Operator State Abbreviation
TX
Operator Postal Code
77389
Local Datetime
2017-07-07 09:15:00
Location Latitude
30.173127
Location Longitude
-90.787278
Commodity Released Type
Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Commodity Subtype
Other Hvl
Commodity Details
Propane
Unintentional Release Bbls
1.88
Intentional Release Bbls
0
Recovered Bbls
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Contractor Working For The Operator
Incident Identified Datetime
2017-07-07 09:15:00
System Part Involved
Onshore Equipment And Piping Associated With Belowground Storage
On Off Shore
Onshore
Shutdown Due Accident Ind
No
Shutdown Explain
The Affected Manifold Pipeline Was Bypassed.
On Site Datetime
2017-07-07 09:15:00
Nrc Rpt Datetime
2017-07-07 12:18:00
Nrc Rpt Num
1183371
Ignite Ind
No
Explode Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Sorrento Dome
Segment Name
Sorrento Dome Propane Manifold
Onshore State Abbreviation
La
Onshore Postal Code
70778
Onshore City Name
Not Within A Municipality
Onshore County Name
Ascension
Designated Location
Milepost/valve Station
Designated Name
Sorrento Dome
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Weld, Including Heat-Affected Zone
Pipe Diameter
4.5
Pipe Wall Thickness
0.366
Pipe Smys
Unknown
Pipe Specification
Unknown
Pipe Seam Type
Seamless
Pipe Manufacturer
Unknown
Pipe Coating Type
Paint
Weld Subtype
Pipe Girth Weld
Installation Year
Unknown
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
No
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
Yes
Usa Ecological Ind
Yes
Usa Ecological Yes No
Yes
Est Cost Oper Paid
0
Est Cost Gas Released
190
Est Cost Prop Damage
40000
Est Cost Emergency
0
Est Cost Environmental
0
Est Cost Other
0
Prpty
40190
Accident Psig
1057
Mop Psig
1450
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Weld failure was determined to be the cause of the release.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Material Failure Of Pipe Or Weld
Cause Details
Design-, Construction-, Installation-, Or Fabrication-Related
Field Exam Ind
Yes
Other Analysis Ind
Yes
Other Analysis Details
Xray Of The Affected Weld
Failure Type
Design-, Construction-, Installation-, Or Fabrication-Related
Other Factor
Yes
Other Factor Details
Unknown
Pwf Additional Other Ind
Yes
Collected Data Ind
No
Has Hydrtst Conduc Before Ind
No
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
K***** L Y****
Preparer Title
Pipeline Safety Compliance Advisor
Preparer Email
K*************@e*********.com
Preparer Telephone
225-324-3055
Prepared Date
2018-03-14 00:00:00
Authorizer Name
C******* B H********
Authorizer Telephone
832-624-7920
Authorizer Title
Empco And Amfo Sshe Manager
Authorizer Email
C*******************@e*********.com
Narrative
On 7/7/2017 a small pinhole was discovered on the bottom of a pipe girth weld connected to a 4" tee located on the sorrento dome propane pipeline manifold between the meters and the storage well. The manifold and associated pipeline was bypassed until repairs were made. Non-destructive x-ray tests determined a faulty weld was the cause of the release. Upon inspection, the cause of the leak was visually verified to be a pinhole due to an incomplete final pass at a girth weld at the 6 o'clock position of a welded tee. Nde found the base pipe material to be competent. Hc manifold is estimated to have been fabricated in the 1950s
| Report Received Date | 2017-08-04 00:00:00 |
|---|---|
| Iyear | 2017 |
| Report Number | 20170237 |
| Supplemental Number | 30043 |
| Report Type | Supplemental Final |
| Operator Id | 4906 PHMSA Enforcement |
| Name | Exxonmobil Pipeline Co |
| Operator Street Address | 22777 Springwoods Village Parkway E2.2b-Emp |
| Operator City Name | Spring |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77389 |
| Local Datetime | 2017-07-07 09:15:00 |
| Location Latitude | 30.173127 Google Maps OpenStreetMap |
| Location Longitude | -90.787278 Google Maps OpenStreetMap |
| Commodity Released Type | Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions |
| Commodity Subtype | Other Hvl |
| Commodity Details | Propane |
| Unintentional Release Bbls | 1.88 |
| Intentional Release Bbls | 0 |
| Recovered Bbls | 0 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Local Operating Personnel, Including Contractors |
| Operator Type | Contractor Working For The Operator |
| Incident Identified Datetime | 2017-07-07 09:15:00 |
| System Part Involved | Onshore Equipment And Piping Associated With Belowground Storage |
| On Off Shore | Onshore |
| Shutdown Due Accident Ind | No |
| Shutdown Explain | The Affected Manifold Pipeline Was Bypassed. |
| On Site Datetime | 2017-07-07 09:15:00 |
| Nrc Rpt Datetime | 2017-07-07 12:18:00 |
| Nrc Rpt Num | 1183371 NRC Report How to search |
| Ignite Ind | No |
| Explode Ind | No |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Sorrento Dome |
| Segment Name | Sorrento Dome Propane Manifold |
| Onshore State Abbreviation | La |
| Onshore Postal Code | 70778 |
| Onshore City Name | Not Within A Municipality |
| Onshore County Name | Ascension |
| Designated Location | Milepost/valve Station |
| Designated Name | Sorrento Dome |
| Federal | No |
| Location Type | Totally Contained On Operator-Controlled Property |
| Incident Area Type | Aboveground |
| Incident Area Subtype | Typical Aboveground Facility Piping Or Appurtenance |
| Crossing | No |
| Pipe Facility Type | Intrastate |
| Item Involved | Weld, Including Heat-Affected Zone |
| Pipe Diameter | 4.5 |
| Pipe Wall Thickness | 0.366 |
| Pipe Smys | Unknown |
| Pipe Specification | Unknown |
| Pipe Seam Type | Seamless |
| Pipe Manufacturer | Unknown |
| Pipe Coating Type | Paint |
| Weld Subtype | Pipe Girth Weld |
| Installation Year | Unknown |
| Manufactured Year | Unknown |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Pinhole |
| Wildlife Impact Ind | No |
| Soil Contamination | No |
| Long Term Assessment | No |
| Remediation Ind | No |
| Water Contam Ind | No |
| Could Be Hca | Yes |
| Commodity Reached Hca | Yes |
| Usa Ecological Ind | Yes |
| Usa Ecological Yes No | Yes |
| Est Cost Oper Paid | 0 |
| Est Cost Gas Released | 190 |
| Est Cost Prop Damage | 40000 |
| Est Cost Emergency | 0 |
| Est Cost Environmental | 0 |
| Est Cost Other | 0 |
| Prpty | 40190 |
| Accident Psig | 1057 |
| Mop Psig | 1450 |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | No |
| Cpm In Place Ind | No |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | Weld failure was determined to be the cause of the release. |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Material Failure Of Pipe Or Weld |
| Cause Details | Design-, Construction-, Installation-, Or Fabrication-Related |
| Field Exam Ind | Yes |
| Other Analysis Ind | Yes |
| Other Analysis Details | Xray Of The Affected Weld |
| Failure Type | Design-, Construction-, Installation-, Or Fabrication-Related |
| Other Factor | Yes |
| Other Factor Details | Unknown |
| Pwf Additional Other Ind | Yes |
| Collected Data Ind | No |
| Has Hydrtst Conduc Before Ind | No |
| Direct Asmnt Conducted | No |
| Non Destructive Exam Ind | No |
| Preparer Name | K***** L Y**** |
| Preparer Title | Pipeline Safety Compliance Advisor |
| Preparer Email | K*************@e*********.com |
| Preparer Telephone | 225-324-3055 |
| Prepared Date | 2018-03-14 00:00:00 |
| Authorizer Name | C******* B H******** |
| Authorizer Telephone | 832-624-7920 |
| Authorizer Title | Empco And Amfo Sshe Manager |
| Authorizer Email | C*******************@e*********.com |
| Narrative | On 7/7/2017 a small pinhole was discovered on the bottom of a pipe girth weld connected to a 4" tee located on the sorrento dome propane pipeline manifold between the meters and the storage well. The manifold and associated pipeline was bypassed until repairs were made. Non-destructive x-ray tests determined a faulty weld was the cause of the release. Upon inspection, the cause of the leak was visually verified to be a pinhole due to an incomplete final pass at a girth weld at the 6 o'clock position of a welded tee. Nde found the base pipe material to be competent. Hc manifold is estimated to have been fabricated in the 1950s |
External Resources