HL incident on 2017-04-20 — OK

Operator
Oneok Ngl Pipeline, Llc
Cause
Incorrect Operation
Commodity
Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$50
Incident datetime
2017-04-20 17:34
Report number
Location
OK
Narrative
On 4/20/2017, oneok crews removed the pig trap closure assembly to install a barrel extension to receive an inline inspection (ili) tool on the oneok- chico pipeline located at the enlink- bridgeport facility. The assembly (flange welded to thread on closure door) had been unbolted and set to the side. After receiving the tool, the closure door assembly was re-installed on the pipeline pig trap, at approximately 13:30, without the closure door ever being opened. The pig trap was purge with hydrocarbons and returned to normal service. At approximately 17:30 onsite enlink operations personnel contacted the oneok pipeline control center to notify of vapors releasing from the oneok chico pipeline pig trap. Oneok field employees were dispatched to the location and isolated the pig trap. Oneok employee's discovered the o-ring on the pig trap closure door had failed and allowed product to escape. A new o-ring was installed and the pig trap returned to service. Oneok inline inspection tool receiving procedure has been amended to include the inspection of the o-ring on the existing pig trap door, even if the door had not been opened but the closure assembly was removed to receive the ili tool. 17/05/17 updated part c, #6 to "leak" -- per direction of PHMSA - alex colletti - nj
Detailed record list
Report Received Date
2017-05-16 00:00:00
Iyear
2017
Report Number
20170164
Supplemental Number
22338
Report Type
Supplemental Final
Operator Id
Name
Oneok Ngl Pipeline, Llc
Operator Street Address
100 West Fifth Street
Operator City Name
Tulsa
Operator State Abbreviation
OK
Operator Postal Code
74103
Local Datetime
2017-04-20 17:34:00
Location Latitude
Location Longitude
Commodity Released Type
Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Commodity Subtype
Lpg (Liquefied Petroleum Gas) / Ngl (Natural Gas Liquid)
Unintentional Release Bbls
22
Intentional Release Bbls
0
Recovered Bbls
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Other
Accident Details
Enlink Plant Operator
Incident Identified Datetime
2017-04-20 17:34:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2017-04-20 18:52:00
Restart Datetime
2017-04-20 21:09:00
On Site Datetime
2017-04-20 19:20:00
Nrc Rpt Num
Nrc Notification Not Required
Ignite Ind
No
Explode Ind
No
Upstream Valve Type Ind
Manual
Downstream Valve Type Ind
Manual
Num Pub Evacuated
0
Pipe Fac Name
Oneok Pig Trap At Enlink Bridgeport Gas Plant
Segment Name
Oneok Wtxlpg Chico Lateral (Index #20601)
Onshore State Abbreviation
Tx
Onshore Postal Code
76426
Onshore City Name
Not Within A Municipality
Onshore County Name
Wise
Designated Location
Milepost/valve Station
Designated Name
Pig Trap
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Scraper/pig Trap
Installation Year
2016
Material Involved
Material Other Than Carbon Steel
Material Details
Viton O-Ring
Release Type
Leak
Leak Type
Seal Or Packing
Wildlife Impact Ind
No
Soil Contamination
No
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
850
Est Cost Prop Damage
50
Est Cost Emergency
500
Est Cost Environmental
0
Est Cost Other
0
Prpty
1400
Accident Psig
700
Mop Psig
1390
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
8
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Oneok controller's had not performed any actions at this location.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Incorrect Operation
Cause Details
Other Incorrect Operation
Operation Type
Other Incorrect Operation
Operation Details
Existing Oneok Procedure For Receiving An Inline Inspection Tool Did Not Include Information Regarding Inspection Of The O-Ring On The Existing Closure Assembly If The Closure Assembly Door Had Not Been Opened. Oneok Procedure Has Been Amended To Include Inspection Of O-Ring On Pig Trap Closure Assembly Doors Even If The Door Was Not Opened.
Related Inadequate Proc Ind
Yes
Category Type
Routine Maintenance
Operator Qualification Ind
Yes
Qualified Individuals
Yes, They Were Qualified For The Task(S)
Preparer Name
N*** J****
Preparer Title
Requlatory Compliance Supervisor
Preparer Email
N*********@o****.com
Preparer Telephone
580-395-6304
Preparer Fax
580-395-2933
Prepared Date
2017-05-17 00:00:00
Authorizer Name
N*** J****
Authorizer Telephone
580-395-6304
Authorizer Title
Regulatory Compliance Supervisor
Authorizer Email
N*********@o****.com
Narrative
On 4/20/2017, oneok crews removed the pig trap closure assembly to install a barrel extension to receive an inline inspection (ili) tool on the oneok- chico pipeline located at the enlink- bridgeport facility. The assembly (flange welded to thread on closure door) had been unbolted and set to the side. After receiving the tool, the closure door assembly was re-installed on the pipeline pig trap, at approximately 13:30, without the closure door ever being opened. The pig trap was purge with hydrocarbons and returned to normal service. At approximately 17:30 onsite enlink operations personnel contacted the oneok pipeline control center to notify of vapors releasing from the oneok chico pipeline pig trap. Oneok field employees were dispatched to the location and isolated the pig trap. Oneok employee's discovered the o-ring on the pig trap closure door had failed and allowed product to escape. A new o-ring was installed and the pig trap returned to service. Oneok inline inspection tool receiving procedure has been amended to include the inspection of the o-ring on the existing pig trap door, even if the door had not been opened but the closure assembly was removed to receive the ili tool. 17/05/17 updated part c, #6 to "leak" -- per direction of PHMSA - alex colletti - nj
Report Received Date 2017-05-16 00:00:00
Iyear 2017
Report Number 20170164
Supplemental Number 22338
Report Type Supplemental Final
Operator Id 32109 PHMSA Enforcement
Name Oneok Ngl Pipeline, Llc
Operator Street Address 100 West Fifth Street
Operator City Name Tulsa
Operator State Abbreviation OK
Operator Postal Code 74103
Local Datetime 2017-04-20 17:34:00
Location Latitude 33.194389 Google Maps OpenStreetMap
Location Longitude -97.805896 Google Maps OpenStreetMap
Commodity Released Type Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Commodity Subtype Lpg (Liquefied Petroleum Gas) / Ngl (Natural Gas Liquid)
Unintentional Release Bbls 22
Intentional Release Bbls 0
Recovered Bbls 0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Other
Accident Details Enlink Plant Operator
Incident Identified Datetime 2017-04-20 17:34:00
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Shutdown Due Accident Ind Yes
Shutdown Datetime 2017-04-20 18:52:00
Restart Datetime 2017-04-20 21:09:00
On Site Datetime 2017-04-20 19:20:00
Nrc Rpt Num Nrc Notification Not Required NRC Report How to search
Ignite Ind No
Explode Ind No
Upstream Valve Type Ind Manual
Downstream Valve Type Ind Manual
Num Pub Evacuated 0
Pipe Fac Name Oneok Pig Trap At Enlink Bridgeport Gas Plant
Segment Name Oneok Wtxlpg Chico Lateral (Index #20601)
Onshore State Abbreviation Tx
Onshore Postal Code 76426
Onshore City Name Not Within A Municipality
Onshore County Name Wise
Designated Location Milepost/valve Station
Designated Name Pig Trap
Federal No
Location Type Totally Contained On Operator-Controlled Property
Incident Area Type Aboveground
Incident Area Subtype Typical Aboveground Facility Piping Or Appurtenance
Crossing No
Pipe Facility Type Interstate
Item Involved Scraper/pig Trap
Installation Year 2016
Material Involved Material Other Than Carbon Steel
Material Details Viton O-Ring
Release Type Leak
Leak Type Seal Or Packing
Wildlife Impact Ind No
Soil Contamination No
Long Term Assessment No
Remediation Ind No
Water Contam Ind No
Could Be Hca No
Commodity Reached Hca No
Est Cost Oper Paid 0
Est Cost Gas Released 850
Est Cost Prop Damage 50
Est Cost Emergency 500
Est Cost Environmental 0
Est Cost Other 0
Prpty 1400
Accident Psig 700
Mop Psig 1390
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Length Segment Isolated 8
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Cpm In Place Ind Yes
Cpm Operating Ind Yes
Cpm Functional Ind Yes
Cpm Detection Ind No
Cpm Conf Ind No
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details Oneok controller's had not performed any actions at this location.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Incorrect Operation
Cause Details Other Incorrect Operation
Operation Type Other Incorrect Operation
Operation Details Existing Oneok Procedure For Receiving An Inline Inspection Tool Did Not Include Information Regarding Inspection Of The O-Ring On The Existing Closure Assembly If The Closure Assembly Door Had Not Been Opened. Oneok Procedure Has Been Amended To Include Inspection Of O-Ring On Pig Trap Closure Assembly Doors Even If The Door Was Not Opened.
Related Inadequate Proc Ind Yes
Category Type Routine Maintenance
Operator Qualification Ind Yes
Qualified Individuals Yes, They Were Qualified For The Task(S)
Preparer Name N*** J****
Preparer Title Requlatory Compliance Supervisor
Preparer Email N*********@o****.com
Preparer Telephone 580-395-6304
Preparer Fax 580-395-2933
Prepared Date 2017-05-17 00:00:00
Authorizer Name N*** J****
Authorizer Telephone 580-395-6304
Authorizer Title Regulatory Compliance Supervisor
Authorizer Email N*********@o****.com
Narrative On 4/20/2017, oneok crews removed the pig trap closure assembly to install a barrel extension to receive an inline inspection (ili) tool on the oneok- chico pipeline located at the enlink- bridgeport facility. The assembly (flange welded to thread on closure door) had been unbolted and set to the side. After receiving the tool, the closure door assembly was re-installed on the pipeline pig trap, at approximately 13:30, without the closure door ever being opened. The pig trap was purge with hydrocarbons and returned to normal service. At approximately 17:30 onsite enlink operations personnel contacted the oneok pipeline control center to notify of vapors releasing from the oneok chico pipeline pig trap. Oneok field employees were dispatched to the location and isolated the pig trap. Oneok employee's discovered the o-ring on the pig trap closure door had failed and allowed product to escape. A new o-ring was installed and the pig trap returned to service. Oneok inline inspection tool receiving procedure has been amended to include the inspection of the o-ring on the existing pig trap door, even if the door had not been opened but the closure assembly was removed to receive the ili tool. 17/05/17 updated part c, #6 to "leak" -- per direction of PHMSA - alex colletti - nj

All rights reserved. Copyright © by ClearPHMSA