GD incident on 2017-09-28 — MI

Operator
Dte Gas Company
Cause
Other Incident Cause
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$1,000
Incident datetime
2017-09-28 03:45
Report number
Location
MI, WAYNE COUNTY
Narrative
Detroit fire and arson has completed its investigation. The cause of the explosion and fire remains unknown.
Detailed record list
Occurred At
2017-09-28 03:45:00
Year
2017
Report Received Date
2017-10-28 00:00:00
Iyear
2017.0
Report Number
20170095.0
Supplemental Number
31027.0
Report Type
Supplemental Final
Operator Id
Name
Dte Gas Company
Operator Street Address
1 Energy Plaza
Operator City Name
Detroit
Operator State Abbreviation
MI
Operator Postal Code
48226
Local Datetime
2017-09-28 03:45:00
Location Street Address
20058 Monica Strret
Location City Name
Detroit
Location County Name
Wayne County
Location State Abbreviation
MI
Location Postal Code
48221
Location Latitude
Location Longitude
Nrc Rpt Datetime
2017-09-28 07:05:00
Nrc Rpt Num
Commodity Released Type
Natural Gas
Unintentional Release
0.0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Ignite Ind
Yes
Explode Ind
Yes
Num Pub Evacuated
0.0
Incident Identified Datetime
2017-09-28 03:45:00
On Site Datetime
2017-09-28 04:05:00
Federal
No
Location Type
Private Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance (E.g. Value Or Regulator Station, Outdoor Meter Set)
Crossing
No
Pipe Facility Type
Privately Owned
System Part Involved
Service
Installation Year
1953.0
Pipe Diameter
1.0
Pipe Specification
Unknown
Pipe Manufacturer
Unknown
Material Involved
Copper
Release Type
Leak
Leak Type
Connection Failure
Class Location Type
Class 3 Location
Est Cost Oper Paid
21864.0
Est Cost Prop Damage
1000.0
Est Cost Emergency
5000.0
Est Cost Other
0.0
Est Cost Unintentional Release
0.0
Prpty
27864.0
Commercial Affected
0.0
Industrial Affected
0.0
Residences Affected
1.0
Accident Psig
2.0
Normal Psig
2.0
Mop Psig
2.0
Accident Pressure
Pressure Did Not Exceed Maop
Scada In Place Ind
No
Accident Identifier
Notification From Emergency Responder
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Other Incident Cause
Cause Details
Unknown
Other Type
Unknown
Unknown Subtype
Investigation Complete, Cause Of Incident Unknown
Preparer Name
J*** D L******
Preparer Title
Principal Compliance Engineer
Preparer Email
J***********@d********.com
Preparer Telephone
616.632.2646
Preparer Fax
616.632.2687
Authorizer Name
J*** D L******
Authorizer Title
Principal Compliance Engineer
Authorizer Telephone
616.632.2646
Authorizer Email
J***********@d********.com
Narrative
Detroit fire and arson has completed its investigation. The cause of the explosion and fire remains unknown.
Occurred At 2017-09-28 03:45:00
Year 2017
Report Received Date 2017-10-28 00:00:00
Iyear 2017.0
Report Number 20170095.0
Supplemental Number 31027.0
Report Type Supplemental Final
Operator Id 12408 PHMSA Enforcement
Name Dte Gas Company
Operator Street Address 1 Energy Plaza
Operator City Name Detroit
Operator State Abbreviation MI
Operator Postal Code 48226
Local Datetime 2017-09-28 03:45:00
Location Street Address 20058 Monica Strret
Location City Name Detroit
Location County Name Wayne County
Location State Abbreviation MI
Location Postal Code 48221
Location Latitude 42.441053 Google Maps OpenStreetMap
Location Longitude -83.144726 Google Maps OpenStreetMap
Nrc Rpt Datetime 2017-09-28 07:05:00
Nrc Rpt Num 1191718 NRC Report How to search
Commodity Released Type Natural Gas
Unintentional Release 0.0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Ignite Ind Yes
Explode Ind Yes
Num Pub Evacuated 0.0
Incident Identified Datetime 2017-09-28 03:45:00
On Site Datetime 2017-09-28 04:05:00
Federal No
Location Type Private Property
Incident Area Type Aboveground
Incident Area Subtype Typical Aboveground Facility Piping Or Appurtenance (E.g. Value Or Regulator Station, Outdoor Meter Set)
Crossing No
Pipe Facility Type Privately Owned
System Part Involved Service
Installation Year 1953.0
Pipe Diameter 1.0
Pipe Specification Unknown
Pipe Manufacturer Unknown
Material Involved Copper
Release Type Leak
Leak Type Connection Failure
Class Location Type Class 3 Location
Est Cost Oper Paid 21864.0
Est Cost Prop Damage 1000.0
Est Cost Emergency 5000.0
Est Cost Other 0.0
Est Cost Unintentional Release 0.0
Prpty 27864.0
Commercial Affected 0.0
Industrial Affected 0.0
Residences Affected 1.0
Accident Psig 2.0
Normal Psig 2.0
Mop Psig 2.0
Accident Pressure Pressure Did Not Exceed Maop
Scada In Place Ind No
Accident Identifier Notification From Emergency Responder
Investigation Status No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Other Incident Cause
Cause Details Unknown
Other Type Unknown
Unknown Subtype Investigation Complete, Cause Of Incident Unknown
Preparer Name J*** D L******
Preparer Title Principal Compliance Engineer
Preparer Email J***********@d********.com
Preparer Telephone 616.632.2646
Preparer Fax 616.632.2687
Authorizer Name J*** D L******
Authorizer Title Principal Compliance Engineer
Authorizer Telephone 616.632.2646
Authorizer Email J***********@d********.com
Narrative Detroit fire and arson has completed its investigation. The cause of the explosion and fire remains unknown.

All rights reserved. Copyright © by ClearPHMSA