Incident details
Operator, cause, commodity and consequences with raw source fields.
GD incident on 2017-05-08 — CA
Operator
Southern California Gas Co
Cause
Pipe, Weld, Or Joint Failure
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$20,354
Incident datetime
2017-05-08 13:55
Report number
Location
CA, SAN BERNARDINO
Narrative
On may 8th, 2017 a leak was discovered near 6205 archibald ave. In rancho cucamonga. Responding socalgas crews located the leak on a aldyl-a plastic 2 inch coupling and affected a repair. No injuries or further damage resulted from this incident. Investigation immediately following the leak repair revealed elevated methane concentrations in the soil surrounding the repaired leak. Crews began to perform vacuum extraction of residual gas per gas standard 184.0426 mitigation of persistent residual gas indications. Extraction operations continued, including the use of contractors, until methane concentrations were returned to normal concentrations. Extraction equipment was removed from the site wednesday june 7th, 2017. Post extraction monitoring continues for 6 weeks until july 19th, 2017 to verify methane concentrations remain at normal concentrations. This incident was reported to the cpuc due to media coverage of gas extraction operation on may 18th. This incident was reported to PHMSA on june 13th, when claims of property damage estimates began coming in, and it was determined those could potentially exceed the $50,000 threshold. When those costs are finalized, a supplemental and final report will be submitted or rescinded as appropriate. Note: the gas loss calculation was based on the time socalgas identified the leak until the time gas was controlled. 12-26-18 - supplemental report submitted with final costs.
Detailed record list
Occurred At
2017-05-08 13:55:00
Year
2017
Report Received Date
2017-06-16 00:00:00
Iyear
2017.0
Report Number
20170049.0
Supplemental Number
31402.0
Report Type
Supplemental Final
Operator Id
18484
Name
Southern California Gas Co
Operator Street Address
555 West Fifth Street
Operator City Name
Los Angeles
Operator State Abbreviation
CA
Operator Postal Code
90013
Local Datetime
2017-05-08 13:55:00
Location Street Address
6205 Archibald Ave
Location City Name
Rancho Cucamonga
Location County Name
San Bernardino
Location State Abbreviation
CA
Location Postal Code
91737
Location Latitude
34.14168
Location Longitude
-117.59341
Nrc Rpt Datetime
2017-06-13 17:20:00
Nrc Rpt Num
1181092
Commodity Released Type
Natural Gas
Unintentional Release
225.0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Ignite Ind
No
Explode Ind
No
Num Pub Evacuated
0.0
Incident Identified Datetime
2017-05-08 13:55:00
On Site Datetime
2017-05-08 19:13:00
Federal
No
Location Type
Public Property
Incident Area Type
Underground
Incident Area Subtype
Under Pavement
Depth Of Cover
36.0
Crossing
Yes
Road Crossing Ind
Yes
Road Type
Uncased
Pipe Facility Type
Investor Owned
System Part Involved
Main
Installation Year
1983.0
Pipe Diameter
2.0
Pipe Specification
Astm 2513
Pipe Manufacturer
Dupont
Material Involved
Plastic
Plastic Type
Polyethylene (Pe)
Plastic Sdr
11
Material Pe Pipe Code
2406
Release Type
Leak
Leak Type
Crack
Class Location Type
Class 3 Location
Est Cost Oper Paid
126060.0
Est Cost Prop Damage
20354.0
Est Cost Emergency
200.0
Est Cost Other
0.0
Est Cost Unintentional Release
1350.0
Prpty
147964.0
Commercial Affected
0.0
Industrial Affected
0.0
Residences Affected
0.0
Accident Psig
55.0
Normal Psig
55.0
Mop Psig
60.0
Accident Pressure
Pressure Did Not Exceed Maop
Scada In Place Ind
No
Accident Identifier
Notification From Public
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Pipe, Weld, Or Joint Failure
Cause Details
Other Pipe, Weld, Or Joint Failure
Pwjf Failure Type
Other Pipe, Weld, Or Joint Failure
Pwjf Failure Details
2" Plastic Socket Fusion Coupling
Additional Pipe Bend Ind
Yes
Result Construction Ind
Yes
Result Construction Subtype
Poor Construction/installation Procedures
Hydrotest Conducted Ind
No
Preparer Name
T*** A* B****
Preparer Title
Pipeline Safety And Compliance Manager
Preparer Email
T*****@s**************.com
Preparer Telephone
909-376-7208
Preparer Fax
909-885-6270
Authorizer Name
T*** A* B****
Authorizer Title
Pipeline Safety And Compliance Manager
Authorizer Telephone
909-376-7208
Authorizer Email
T*****@s**************.com
Narrative
On may 8th, 2017 a leak was discovered near 6205 archibald ave. In rancho cucamonga. Responding socalgas crews located the leak on a aldyl-a plastic 2 inch coupling and affected a repair. No injuries or further damage resulted from this incident. Investigation immediately following the leak repair revealed elevated methane concentrations in the soil surrounding the repaired leak. Crews began to perform vacuum extraction of residual gas per gas standard 184.0426 mitigation of persistent residual gas indications. Extraction operations continued, including the use of contractors, until methane concentrations were returned to normal concentrations. Extraction equipment was removed from the site wednesday june 7th, 2017. Post extraction monitoring continues for 6 weeks until july 19th, 2017 to verify methane concentrations remain at normal concentrations. This incident was reported to the cpuc due to media coverage of gas extraction operation on may 18th. This incident was reported to PHMSA on june 13th, when claims of property damage estimates began coming in, and it was determined those could potentially exceed the $50,000 threshold. When those costs are finalized, a supplemental and final report will be submitted or rescinded as appropriate. Note: the gas loss calculation was based on the time socalgas identified the leak until the time gas was controlled. 12-26-18 - supplemental report submitted with final costs.
| Occurred At | 2017-05-08 13:55:00 |
|---|---|
| Year | 2017 |
| Report Received Date | 2017-06-16 00:00:00 |
| Iyear | 2017.0 |
| Report Number | 20170049.0 |
| Supplemental Number | 31402.0 |
| Report Type | Supplemental Final |
| Operator Id | 18484 PHMSA Enforcement |
| Name | Southern California Gas Co |
| Operator Street Address | 555 West Fifth Street |
| Operator City Name | Los Angeles |
| Operator State Abbreviation | CA |
| Operator Postal Code | 90013 |
| Local Datetime | 2017-05-08 13:55:00 |
| Location Street Address | 6205 Archibald Ave |
| Location City Name | Rancho Cucamonga |
| Location County Name | San Bernardino |
| Location State Abbreviation | CA |
| Location Postal Code | 91737 |
| Location Latitude | 34.14168 Google Maps OpenStreetMap |
| Location Longitude | -117.59341 Google Maps OpenStreetMap |
| Nrc Rpt Datetime | 2017-06-13 17:20:00 |
| Nrc Rpt Num | 1181092 NRC Report How to search |
| Commodity Released Type | Natural Gas |
| Unintentional Release | 225.0 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Ignite Ind | No |
| Explode Ind | No |
| Num Pub Evacuated | 0.0 |
| Incident Identified Datetime | 2017-05-08 13:55:00 |
| On Site Datetime | 2017-05-08 19:13:00 |
| Federal | No |
| Location Type | Public Property |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Pavement |
| Depth Of Cover | 36.0 |
| Crossing | Yes |
| Road Crossing Ind | Yes |
| Road Type | Uncased |
| Pipe Facility Type | Investor Owned |
| System Part Involved | Main |
| Installation Year | 1983.0 |
| Pipe Diameter | 2.0 |
| Pipe Specification | Astm 2513 |
| Pipe Manufacturer | Dupont |
| Material Involved | Plastic |
| Plastic Type | Polyethylene (Pe) |
| Plastic Sdr | 11 |
| Material Pe Pipe Code | 2406 |
| Release Type | Leak |
| Leak Type | Crack |
| Class Location Type | Class 3 Location |
| Est Cost Oper Paid | 126060.0 |
| Est Cost Prop Damage | 20354.0 |
| Est Cost Emergency | 200.0 |
| Est Cost Other | 0.0 |
| Est Cost Unintentional Release | 1350.0 |
| Prpty | 147964.0 |
| Commercial Affected | 0.0 |
| Industrial Affected | 0.0 |
| Residences Affected | 0.0 |
| Accident Psig | 55.0 |
| Normal Psig | 55.0 |
| Mop Psig | 60.0 |
| Accident Pressure | Pressure Did Not Exceed Maop |
| Scada In Place Ind | No |
| Accident Identifier | Notification From Public |
| Investigation Status | No, the facility was not monitored by a controller(s) at the time of the incident |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Pipe, Weld, Or Joint Failure |
| Cause Details | Other Pipe, Weld, Or Joint Failure |
| Pwjf Failure Type | Other Pipe, Weld, Or Joint Failure |
| Pwjf Failure Details | 2" Plastic Socket Fusion Coupling |
| Additional Pipe Bend Ind | Yes |
| Result Construction Ind | Yes |
| Result Construction Subtype | Poor Construction/installation Procedures |
| Hydrotest Conducted Ind | No |
| Preparer Name | T*** A* B**** |
| Preparer Title | Pipeline Safety And Compliance Manager |
| Preparer Email | T*****@s**************.com |
| Preparer Telephone | 909-376-7208 |
| Preparer Fax | 909-885-6270 |
| Authorizer Name | T*** A* B**** |
| Authorizer Title | Pipeline Safety And Compliance Manager |
| Authorizer Telephone | 909-376-7208 |
| Authorizer Email | T*****@s**************.com |
| Narrative | On may 8th, 2017 a leak was discovered near 6205 archibald ave. In rancho cucamonga. Responding socalgas crews located the leak on a aldyl-a plastic 2 inch coupling and affected a repair. No injuries or further damage resulted from this incident. Investigation immediately following the leak repair revealed elevated methane concentrations in the soil surrounding the repaired leak. Crews began to perform vacuum extraction of residual gas per gas standard 184.0426 mitigation of persistent residual gas indications. Extraction operations continued, including the use of contractors, until methane concentrations were returned to normal concentrations. Extraction equipment was removed from the site wednesday june 7th, 2017. Post extraction monitoring continues for 6 weeks until july 19th, 2017 to verify methane concentrations remain at normal concentrations. This incident was reported to the cpuc due to media coverage of gas extraction operation on may 18th. This incident was reported to PHMSA on june 13th, when claims of property damage estimates began coming in, and it was determined those could potentially exceed the $50,000 threshold. When those costs are finalized, a supplemental and final report will be submitted or rescinded as appropriate. Note: the gas loss calculation was based on the time socalgas identified the leak until the time gas was controlled. 12-26-18 - supplemental report submitted with final costs. |
External Resources
PHMSA pipeline safety insights.
Product