Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2014-10-08 — TX
Operator
Wyoming Pipeline Company
Cause
Other Outside Force Damage
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$200
Incident datetime
2014-10-08 07:00
Report number
Location
TX
Narrative
Truck driver coming into wyoming pipeline company's thunder creek station hit and broke the threaded collar on a dump box with his trailer. The driver then notified wpc operator of the accident; the operator dispatched a vac truck to thunder creek. Crude oil was vacuumed up and crude oil was put into tank. All costs were paid by plains.
Detailed record list
Report Received Date
2016-11-18 00:00:00
Iyear
2014
Report Number
20160387
Supplemental Number
22885
Report Type
Supplemental Final
Operator Id
32537
Name
Wyoming Pipeline Company
Operator Street Address
825 Town & Country Lane
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77024
Local Datetime
2014-10-08 07:00:00
Location Latitude
43.787925
Location Longitude
-104.4171139
Commodity Released Type
Crude Oil
Unintentional Release Bbls
45
Recovered Bbls
45
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Notification From Third Party That Caused The Accident
Incident Identified Datetime
2014-10-08 07:00:00
System Part Involved
Onshore Pump/meter Station Equipment And Piping
On Off Shore
Onshore
Shutdown Due Accident Ind
No
Shutdown Explain
Third Party Struck Their Own Valve And Caused This Release
On Site Datetime
2014-10-08 07:40:00
Nrc Rpt Num
Nrc Notification Not Required
Ignite Ind
No
Explode Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Wyoming Pipeline Company
Segment Name
Thunder Crk Station - Plains Mkt Dump Box Valve
Onshore State Abbreviation
Wy
Onshore Postal Code
82701
Onshore City Name
Not Within A Municipality
Onshore County Name
Weston County
Designated Location
Milepost/valve Station
Designated Name
Thunder Creek
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Other
Incident Area Details
Dump Box Valve
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Valve
Valve Type
Auxiliary Or Other Valve
Installation Year
Unknown
Material Involved
Carbon Steel
Release Type
Other
Release Type Details
Truck Driver Hit And Broke Threaded Collar On Dump Box With His Trailer. This Was Plains Valve Box And Equipment, Not Regulated Wpc Facility, However It Was On Wpc Property Which Is Why It Is Being Reported
Wildlife Impact Ind
No
Soil Contamination
No
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
0
Est Cost Prop Damage
200
Est Cost Emergency
600
Est Cost Environmental
7185
Est Cost Other
4655
Est Cost Other Details
Costs Paid By Plains To Clean Up The Spill. Damage Was To Their Valve Box.
Prpty
12640
Accident Psig
5
Mop Psig
20
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
< 20% Smys Regulated Transmission
Scada In Place Ind
No
Cpm In Place Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Notification came from the third party that caused the accident. Scada can not see this appurtenance.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Other Outside Force Damage
Cause Details
Damage By Car, Truck, Or Other Motorized Vehicle/equipment Not Engaged In Excavation
Outside Force Type
Damage By Car, Truck, Or Other Motorized Vehicle/equipment Not Engaged In Excavation
Vehicle Subtype
Third Party
Preparer Name
W****** M********
Preparer Title
Compliance Consultant
Preparer Email
W*****@c**.net
Preparer Telephone
405-820-1304
Prepared Date
2017-12-06 00:00:00
Authorizer Name
N***** H******
Authorizer Telephone
307-746-9479
Authorizer Title
Environmental Engineer
Authorizer Email
N*******@p*********.com
Narrative
Truck driver coming into wyoming pipeline company's thunder creek station hit and broke the threaded collar on a dump box with his trailer. The driver then notified wpc operator of the accident; the operator dispatched a vac truck to thunder creek. Crude oil was vacuumed up and crude oil was put into tank. All costs were paid by plains.
| Report Received Date | 2016-11-18 00:00:00 |
|---|---|
| Iyear | 2014 |
| Report Number | 20160387 |
| Supplemental Number | 22885 |
| Report Type | Supplemental Final |
| Operator Id | 32537 PHMSA Enforcement |
| Name | Wyoming Pipeline Company |
| Operator Street Address | 825 Town & Country Lane |
| Operator City Name | Houston |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77024 |
| Local Datetime | 2014-10-08 07:00:00 |
| Location Latitude | 43.787925 Google Maps OpenStreetMap |
| Location Longitude | -104.4171139 Google Maps OpenStreetMap |
| Commodity Released Type | Crude Oil |
| Unintentional Release Bbls | 45 |
| Recovered Bbls | 45 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Notification From Third Party That Caused The Accident |
| Incident Identified Datetime | 2014-10-08 07:00:00 |
| System Part Involved | Onshore Pump/meter Station Equipment And Piping |
| On Off Shore | Onshore |
| Shutdown Due Accident Ind | No |
| Shutdown Explain | Third Party Struck Their Own Valve And Caused This Release |
| On Site Datetime | 2014-10-08 07:40:00 |
| Nrc Rpt Num | Nrc Notification Not Required NRC Report How to search |
| Ignite Ind | No |
| Explode Ind | No |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Wyoming Pipeline Company |
| Segment Name | Thunder Crk Station - Plains Mkt Dump Box Valve |
| Onshore State Abbreviation | Wy |
| Onshore Postal Code | 82701 |
| Onshore City Name | Not Within A Municipality |
| Onshore County Name | Weston County |
| Designated Location | Milepost/valve Station |
| Designated Name | Thunder Creek |
| Federal | No |
| Location Type | Totally Contained On Operator-Controlled Property |
| Incident Area Type | Aboveground |
| Incident Area Subtype | Other |
| Incident Area Details | Dump Box Valve |
| Crossing | No |
| Pipe Facility Type | Intrastate |
| Item Involved | Valve |
| Valve Type | Auxiliary Or Other Valve |
| Installation Year | Unknown |
| Material Involved | Carbon Steel |
| Release Type | Other |
| Release Type Details | Truck Driver Hit And Broke Threaded Collar On Dump Box With His Trailer. This Was Plains Valve Box And Equipment, Not Regulated Wpc Facility, However It Was On Wpc Property Which Is Why It Is Being Reported |
| Wildlife Impact Ind | No |
| Soil Contamination | No |
| Long Term Assessment | No |
| Remediation Ind | No |
| Water Contam Ind | No |
| Could Be Hca | No |
| Commodity Reached Hca | No |
| Est Cost Oper Paid | 0 |
| Est Cost Gas Released | 0 |
| Est Cost Prop Damage | 200 |
| Est Cost Emergency | 600 |
| Est Cost Environmental | 7185 |
| Est Cost Other | 4655 |
| Est Cost Other Details | Costs Paid By Plains To Clean Up The Spill. Damage Was To Their Valve Box. |
| Prpty | 12640 |
| Accident Psig | 5 |
| Mop Psig | 20 |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Pipeline Function | < 20% Smys Regulated Transmission |
| Scada In Place Ind | No |
| Cpm In Place Ind | No |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | Notification came from the third party that caused the accident. Scada can not see this appurtenance. |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Other Outside Force Damage |
| Cause Details | Damage By Car, Truck, Or Other Motorized Vehicle/equipment Not Engaged In Excavation |
| Outside Force Type | Damage By Car, Truck, Or Other Motorized Vehicle/equipment Not Engaged In Excavation |
| Vehicle Subtype | Third Party |
| Preparer Name | W****** M******** |
| Preparer Title | Compliance Consultant |
| Preparer Email | W*****@c**.net |
| Preparer Telephone | 405-820-1304 |
| Prepared Date | 2017-12-06 00:00:00 |
| Authorizer Name | N***** H****** |
| Authorizer Telephone | 307-746-9479 |
| Authorizer Title | Environmental Engineer |
| Authorizer Email | N*******@p*********.com |
| Narrative | Truck driver coming into wyoming pipeline company's thunder creek station hit and broke the threaded collar on a dump box with his trailer. The driver then notified wpc operator of the accident; the operator dispatched a vac truck to thunder creek. Crude oil was vacuumed up and crude oil was put into tank. All costs were paid by plains. |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company
All rights reserved. Copyright © by ClearPHMSA