HL incident on 2016-07-06 — TX

Operator
Plantation Pipe Line Co
Cause
Material Failure Of Pipe Or Weld
Commodity
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$246,000
Incident datetime
2016-07-06 18:30
Report number
Location
TX
Narrative
On july 6, 2016, company personnel along with right-of-way (row) mowers, came upon a location on the row where the soil was moist and it had an unusual odor. The company personnel called his manager to communicate his observations. The control center was contacted and the pipeline was shutdown. Agency notifications were made and resources were mobilized to the site. The pipeline was excavated in the area of the moist soil and odor and a small crack in the long seam of the pipe was discovered. The failed pipe segment was replace with a new pipe segment. The crack was the result of an upturned fiber in the electric resistance weld seam present since pipe manufacturing.
Detailed record list
Report Received Date
2016-08-04 00:00:00
Iyear
2016
Report Number
20160242
Supplemental Number
21682
Report Type
Supplemental Final
Operator Id
Name
Plantation Pipe Line Co
Operator Street Address
1001 Louisiana St Suite 1000
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2016-07-06 18:30:00
Location Latitude
Location Longitude
-77.61972897
Commodity Released Type
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype
Gasoline (Non-Ethanol)
Unintentional Release Bbls
12.05
Recovered Bbls
11.93
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
Incident Identified Datetime
2016-07-06 18:30:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2016-07-06 16:09:00
Restart Datetime
2016-07-07 21:55:00
On Site Datetime
2016-07-06 18:30:00
Nrc Rpt Datetime
2016-07-06 18:47:00
Nrc Rpt Num
Ignite Ind
No
Explode Ind
No
Upstream Valve Type Ind
Remotely Controlled
Downstream Valve Type Ind
Remotely Controlled
Num Pub Evacuated
0
Pipe Fac Name
14w-12
Segment Name
Line Section 17a
Onshore State Abbreviation
Va
Onshore Postal Code
23063
Onshore City Name
Not Within A Municipality
Onshore County Name
Goochland
Designated Location
Survey Station No.
Designated Name
541+53.56
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
48
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pipe
Pipe Type
Pipe Seam
Pipe Diameter
12.75
Pipe Wall Thickness
0.203
Pipe Smys
52000
Pipe Specification
Api 5l
Pipe Seam Type
Erw - Low Frequency
Pipe Manufacturer
Bethlehem
Pipe Coating Type
Coal Tar
Installation Year
1964
Manufactured Year
1964
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Crack
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
Yes
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
Yes
High Pop Ind
Yes
High Pop Yes No
Yes
Est Cost Oper Paid
0
Est Cost Gas Released
700
Est Cost Prop Damage
246000
Est Cost Emergency
132000
Est Cost Environmental
46000
Est Cost Other
0
Prpty
424700
Accident Psig
521
Mop Psig
1142
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
127929
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
Yes, specify investigation result(s): (select all that apply)
Invest Schedule Ind
Yes
Invest No Control Room Ind
Yes
Invest No Controller Ind
Yes
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Material Failure Of Pipe Or Weld
Cause Details
Original Manufacturing-Related (Not Girth Weld Or Other Welds Formed In The Field)
Metallurgical Ind
Yes
Failure Type
Original Manufacturing-Related (Not Girth Weld Or Other Welds Formed In The Field)
Other Factor
Yes
Other Factor Details
Upturned Fiber In The Electric Resistance Weld Seam Present Since Pipe Manufactu
Additional Crack Ind
Yes
Collected Data Ind
Yes
Cir Trn Wave Mgn Flx Lkg Ind
Yes
Geometry Deformation Ind
Yes
Circ Wave Recent Year
2015
Geometry Recent Year
2015
Has Hydrtst Conduc Before Ind
Yes
Hydrtst Most Rcnt Year
1997
Hydrtst Most Rcnt Pressure
1427
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
Q****** H* F******
Preparer Title
Manager-Compliance Codes And Standards
Preparer Email
Q**************@k***********.com
Preparer Telephone
770-751-4240
Prepared Date
2016-09-09 00:00:00
Authorizer Name
Q****** H* F******
Authorizer Telephone
770-751-4240
Authorizer Title
Manager-Compliance Codes And Standards
Authorizer Email
Q**************@k***********.com
Narrative
On july 6, 2016, company personnel along with right-of-way (row) mowers, came upon a location on the row where the soil was moist and it had an unusual odor. The company personnel called his manager to communicate his observations. The control center was contacted and the pipeline was shutdown. Agency notifications were made and resources were mobilized to the site. The pipeline was excavated in the area of the moist soil and odor and a small crack in the long seam of the pipe was discovered. The failed pipe segment was replace with a new pipe segment. The crack was the result of an upturned fiber in the electric resistance weld seam present since pipe manufacturing.
Report Received Date 2016-08-04 00:00:00
Iyear 2016
Report Number 20160242
Supplemental Number 21682
Report Type Supplemental Final
Operator Id 15674 PHMSA Enforcement
Name Plantation Pipe Line Co
Operator Street Address 1001 Louisiana St Suite 1000
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77002
Local Datetime 2016-07-06 18:30:00
Location Latitude 37.586723 Google Maps OpenStreetMap
Location Longitude -77.61972897 Google Maps OpenStreetMap
Commodity Released Type Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype Gasoline (Non-Ethanol)
Unintentional Release Bbls 12.05
Recovered Bbls 11.93
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Local Operating Personnel, Including Contractors
Operator Type Operator Employee
Incident Identified Datetime 2016-07-06 18:30:00
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Shutdown Due Accident Ind Yes
Shutdown Datetime 2016-07-06 16:09:00
Restart Datetime 2016-07-07 21:55:00
On Site Datetime 2016-07-06 18:30:00
Nrc Rpt Datetime 2016-07-06 18:47:00
Nrc Rpt Num 1152593 NRC Report How to search
Ignite Ind No
Explode Ind No
Upstream Valve Type Ind Remotely Controlled
Downstream Valve Type Ind Remotely Controlled
Num Pub Evacuated 0
Pipe Fac Name 14w-12
Segment Name Line Section 17a
Onshore State Abbreviation Va
Onshore Postal Code 23063
Onshore City Name Not Within A Municipality
Onshore County Name Goochland
Designated Location Survey Station No.
Designated Name 541+53.56
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 48
Crossing No
Pipe Facility Type Interstate
Item Involved Pipe
Pipe Type Pipe Seam
Pipe Diameter 12.75
Pipe Wall Thickness 0.203
Pipe Smys 52000
Pipe Specification Api 5l
Pipe Seam Type Erw - Low Frequency
Pipe Manufacturer Bethlehem
Pipe Coating Type Coal Tar
Installation Year 1964
Manufactured Year 1964
Material Involved Carbon Steel
Release Type Leak
Leak Type Crack
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment Yes
Remediation Ind No
Water Contam Ind No
Could Be Hca Yes
Commodity Reached Hca Yes
High Pop Ind Yes
High Pop Yes No Yes
Est Cost Oper Paid 0
Est Cost Gas Released 700
Est Cost Prop Damage 246000
Est Cost Emergency 132000
Est Cost Environmental 46000
Est Cost Other 0
Prpty 424700
Accident Psig 521
Mop Psig 1142
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Length Segment Isolated 127929
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Cpm In Place Ind No
Investigation Status Yes, specify investigation result(s): (select all that apply)
Invest Schedule Ind Yes
Invest No Control Room Ind Yes
Invest No Controller Ind Yes
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Material Failure Of Pipe Or Weld
Cause Details Original Manufacturing-Related (Not Girth Weld Or Other Welds Formed In The Field)
Metallurgical Ind Yes
Failure Type Original Manufacturing-Related (Not Girth Weld Or Other Welds Formed In The Field)
Other Factor Yes
Other Factor Details Upturned Fiber In The Electric Resistance Weld Seam Present Since Pipe Manufactu
Additional Crack Ind Yes
Collected Data Ind Yes
Cir Trn Wave Mgn Flx Lkg Ind Yes
Geometry Deformation Ind Yes
Circ Wave Recent Year 2015
Geometry Recent Year 2015
Has Hydrtst Conduc Before Ind Yes
Hydrtst Most Rcnt Year 1997
Hydrtst Most Rcnt Pressure 1427
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Preparer Name Q****** H* F******
Preparer Title Manager-Compliance Codes And Standards
Preparer Email Q**************@k***********.com
Preparer Telephone 770-751-4240
Prepared Date 2016-09-09 00:00:00
Authorizer Name Q****** H* F******
Authorizer Telephone 770-751-4240
Authorizer Title Manager-Compliance Codes And Standards
Authorizer Email Q**************@k***********.com
Narrative On july 6, 2016, company personnel along with right-of-way (row) mowers, came upon a location on the row where the soil was moist and it had an unusual odor. The company personnel called his manager to communicate his observations. The control center was contacted and the pipeline was shutdown. Agency notifications were made and resources were mobilized to the site. The pipeline was excavated in the area of the moist soil and odor and a small crack in the long seam of the pipe was discovered. The failed pipe segment was replace with a new pipe segment. The crack was the result of an upturned fiber in the electric resistance weld seam present since pipe manufacturing.

All rights reserved. Copyright © by ClearPHMSA