HL incident on 2016-07-06 — TX

Operator
Enterprise Crude Pipeline Llc
Cause
Corrosion Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$46,260
Incident datetime
2016-07-06 10:15
Report number
Location
TX
Narrative
On 07/06/16 at 10:15 am, a pin hole leak caused by sand blasting activity during a planned rehab excavation dig from an ili run that resulted in the release of one barrel of crude oil. A plidco clamp was immediately installed to stop the leak. At 11:00 am, it was determined that the permanent repair would be to install a type b sleeve with a repair cost exceeding $50,000 thus nrc reportable. Update: lid c47 has been idled of all hazardous material and is operating under a nitrogen blanket. Idling this line remediates any necessary repairs or analysis due to the absence of hazardous material.
Detailed record list
Report Received Date
2016-08-02 00:00:00
Iyear
2016
Report Number
20160240
Supplemental Number
30550
Report Type
Supplemental Final
Operator Id
Name
Enterprise Crude Pipeline Llc
Operator Street Address
1100 Louisiana Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2016-07-06 10:15:00
Location Latitude
Location Longitude
Commodity Released Type
Crude Oil
Unintentional Release Bbls
1
Recovered Bbls
1
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Contractor Working For The Operator
Incident Identified Datetime
2016-07-06 10:15:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2016-07-06 10:15:00
Restart Datetime
2016-07-06 13:47:00
On Site Datetime
2016-07-06 10:15:00
Nrc Rpt Datetime
2016-07-06 11:30:00
Nrc Rpt Num
Ignite Ind
No
Explode Ind
No
Upstream Valve Type Ind
Manual
Downstream Valve Type Ind
Manual
Num Pub Evacuated
0
Pipe Fac Name
C47
Segment Name
Aid 10001
Onshore State Abbreviation
Tx
Onshore Postal Code
76310
Onshore City Name
Lakeside City
Onshore County Name
Archer
Designated Location
Milepost/valve Station
Designated Name
Gps Location
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
Unknown
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Pipe
Pipe Type
Pipe Body
Pipe Diameter
8.625
Pipe Wall Thickness
0.25
Pipe Smys
35000
Pipe Specification
Grade B
Pipe Seam Type
Seamless
Pipe Manufacturer
Unknown
Pipe Coating Type
Coal Tar
Installation Year
Unknown
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
0
Est Cost Prop Damage
46260
Est Cost Emergency
0
Est Cost Environmental
0
Est Cost Other
0
Est Cost Other Details
0
Prpty
46260
Accident Psig
95
Mop Psig
720
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
Yes
Exceed Restriction Ind
No
Phmsa Restriction Ind
Phmsa
Length Segment Isolated
62320
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Abrasive blasting caused the accident not the control room
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
External Corrosion
Internal External
External Corrosion
Visual Exam Results
General Corrosion
Other Corrosion Ind
Yes
Corrosion Type Details
General External Corrosion
Field Exam Basis Ind
Yes
Underground Location
Yes
Under Cathodic Protection Ind
Yes
Cathodic Pro Start Year
Unknown
Shielding Evident
Unknown
Cathodic Survey Type
Yes
Cp Annual Survey Ind
Yes
Close Interval Survey Ind
Yes
Cp Annual Survey Year
2016
Close Interval Survey Year
2014
Prior Damage
Yes
Collected Data Ind
Yes
Axial Magnetic Flx Lkg Ind
Yes
Geometry Deformation Ind
Yes
Axial Recent Year
2014
Geometry Recent Year
2014
Has Hydrtst Conduc Before Ind
No
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
L**** W*******
Preparer Title
Pipeline Compliance Senior Engineer
Preparer Email
L*********@e****.com
Preparer Telephone
7133816748
Prepared Date
2018-06-26 00:00:00
Authorizer Name
L**** W*******
Authorizer Telephone
7133816748
Authorizer Email
L*********@e****.com
Narrative
On 07/06/16 at 10:15 am, a pin hole leak caused by sand blasting activity during a planned rehab excavation dig from an ili run that resulted in the release of one barrel of crude oil. A plidco clamp was immediately installed to stop the leak. At 11:00 am, it was determined that the permanent repair would be to install a type b sleeve with a repair cost exceeding $50,000 thus nrc reportable. Update: lid c47 has been idled of all hazardous material and is operating under a nitrogen blanket. Idling this line remediates any necessary repairs or analysis due to the absence of hazardous material.
Report Received Date 2016-08-02 00:00:00
Iyear 2016
Report Number 20160240
Supplemental Number 30550
Report Type Supplemental Final
Operator Id 30829 PHMSA Enforcement
Name Enterprise Crude Pipeline Llc
Operator Street Address 1100 Louisiana Street
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77002
Local Datetime 2016-07-06 10:15:00
Location Latitude 33.80808 Google Maps OpenStreetMap
Location Longitude -98.54305 Google Maps OpenStreetMap
Commodity Released Type Crude Oil
Unintentional Release Bbls 1
Recovered Bbls 1
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Local Operating Personnel, Including Contractors
Operator Type Contractor Working For The Operator
Incident Identified Datetime 2016-07-06 10:15:00
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Shutdown Due Accident Ind Yes
Shutdown Datetime 2016-07-06 10:15:00
Restart Datetime 2016-07-06 13:47:00
On Site Datetime 2016-07-06 10:15:00
Nrc Rpt Datetime 2016-07-06 11:30:00
Nrc Rpt Num 1152558 NRC Report How to search
Ignite Ind No
Explode Ind No
Upstream Valve Type Ind Manual
Downstream Valve Type Ind Manual
Num Pub Evacuated 0
Pipe Fac Name C47
Segment Name Aid 10001
Onshore State Abbreviation Tx
Onshore Postal Code 76310
Onshore City Name Lakeside City
Onshore County Name Archer
Designated Location Milepost/valve Station
Designated Name Gps Location
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover Unknown
Crossing No
Pipe Facility Type Intrastate
Item Involved Pipe
Pipe Type Pipe Body
Pipe Diameter 8.625
Pipe Wall Thickness 0.25
Pipe Smys 35000
Pipe Specification Grade B
Pipe Seam Type Seamless
Pipe Manufacturer Unknown
Pipe Coating Type Coal Tar
Installation Year Unknown
Manufactured Year Unknown
Material Involved Carbon Steel
Release Type Leak
Leak Type Pinhole
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment No
Remediation Ind No
Water Contam Ind No
Could Be Hca Yes
Commodity Reached Hca No
Est Cost Oper Paid 0
Est Cost Gas Released 0
Est Cost Prop Damage 46260
Est Cost Emergency 0
Est Cost Environmental 0
Est Cost Other 0
Est Cost Other Details 0
Prpty 46260
Accident Psig 95
Mop Psig 720
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind Yes
Exceed Restriction Ind No
Phmsa Restriction Ind Phmsa
Length Segment Isolated 62320
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Cpm In Place Ind Yes
Cpm Operating Ind Yes
Cpm Functional Ind Yes
Cpm Detection Ind No
Cpm Conf Ind No
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details Abrasive blasting caused the accident not the control room
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Corrosion Failure
Cause Details External Corrosion
Internal External External Corrosion
Visual Exam Results General Corrosion
Other Corrosion Ind Yes
Corrosion Type Details General External Corrosion
Field Exam Basis Ind Yes
Underground Location Yes
Under Cathodic Protection Ind Yes
Cathodic Pro Start Year Unknown
Shielding Evident Unknown
Cathodic Survey Type Yes
Cp Annual Survey Ind Yes
Close Interval Survey Ind Yes
Cp Annual Survey Year 2016
Close Interval Survey Year 2014
Prior Damage Yes
Collected Data Ind Yes
Axial Magnetic Flx Lkg Ind Yes
Geometry Deformation Ind Yes
Axial Recent Year 2014
Geometry Recent Year 2014
Has Hydrtst Conduc Before Ind No
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Preparer Name L**** W*******
Preparer Title Pipeline Compliance Senior Engineer
Preparer Email L*********@e****.com
Preparer Telephone 7133816748
Prepared Date 2018-06-26 00:00:00
Authorizer Name L**** W*******
Authorizer Telephone 7133816748
Authorizer Email L*********@e****.com
Narrative On 07/06/16 at 10:15 am, a pin hole leak caused by sand blasting activity during a planned rehab excavation dig from an ili run that resulted in the release of one barrel of crude oil. A plidco clamp was immediately installed to stop the leak. At 11:00 am, it was determined that the permanent repair would be to install a type b sleeve with a repair cost exceeding $50,000 thus nrc reportable. Update: lid c47 has been idled of all hazardous material and is operating under a nitrogen blanket. Idling this line remediates any necessary repairs or analysis due to the absence of hazardous material.